Air for Type Integrated WxDxH fitting area power consumption combustion pressure G UNI-ISO n° kg/h m³/h regulation 7/1 R1 ½ GV 455 42x55x31,5 0,540 ½ 80x55x31,5 13,8 1,080 GV 855 119,5x55x31,5 20,7 1,620 GV 1255 ½ GV 470 42x70x31,5 0,67 ½...
Page 3
( 1 ) TECHNICAL CHARACTERISTICS The nameplate is positioned on the front or inside the control panel, you gain access to it by unscrewing and removing the control panel. - II2H3+ category appliance ( version without pressure regulation ) - I2H category appliance ( version with pressure regulation ) - Inlet pressure: Butane/Propane (G30-G31) 30/37mbar Natural gas *H* (G20) 20mbar...
Page 4
BURNER: series 700/710 (GV ...7) - ONE AREA - NOMINAL INPUT kW 10,5 REDUCED INPUT kW 8,5 Main burner Pilot light By-pass “X “ = mm* injectors Ø 1/100mm injectors n° Ø 1/100 Main burner primary air Liquid gas (G30-G31) Natural gas 29.2 Adjustable...
Page 5
( 4 ) GENERAL WARNINGS - INSTALLATION Carefully read the warnings container in this booklet in that they provide important indications regarding installation, use and maintenance safety. Keep this booklet for further consultation by the various operators. After having removed the packaging make sure that the appliance is complete. In case of doubt, do not use the appliance and consult professionally qualified personnel.
Page 6
( 5 ) INSTALLATION OF THE APPLIANCE The gas systems and the installation site of the appliance must be in accordance with the regulations in the various areas and in particular you must consider that the air for combustion in the burners is 2m /h for every kW of power installed and that the accident prevention standards must be observed.
Page 7
( 6 ) SMOKE EXHAUST The appliance must be installed in rooms suitable for the exhaust of the products of combustion which must occur in observance of that prescribed by the installation standards. Our appliances are considered as type A gas appliances (see technical data charts). Such appliances must discharge in special hoods or similar device, connected to a surely efficient duct which discharges directly to the outside.
Page 8
( 8 ) OPERATION WITH SUPPLY GAS IDENTICAL TO THAT PRESET Check if the indication on the nameplate correspond to the gas distributed, check also the correspondence of the following. ( 8-a ) Checking the inlet (Fig. 3) THE APPLIANCES ARE NOT SUPPLIED WITH PRESSURE REGULATOR ( MODEL WITHOUT THE ABBREVIATION …..R), ITS CATEGORY IS II2H3+ AND CAN BE ADAPTED TO OTHER TYPES OF GAS (for example from natural gas to LPG and vice versa).
Page 9
( 9 ) ADJUSTMENT FOR OPERATE WITH OTHER TYPES OF GAS BEFORE ADJUSTING CHECK THE GAS CATEGORY OF THE APPLIANCE. If the appliance has category I2.. it will be supplied with pressure regulator. In this case NO CHANGES ARE ALLOWED. If the appliance has gas category II..
NOTES FOR THE USER (12) USE NOTES The appliance must be used by qualified personnel, being an appliance exclusively for professional kitchens. The installation operations, any transformations for use with other types of gas, the setting at work, the elimination of any inconvenient to the system, must be done only by qualified personnel in accordance with the standards in force.
7. MAINTENANCE It is recommended to draw up a contract for maintenance at least once a year. If the rotation of the knob stiffens, it is also recommended to have the cocks directly replaced by the technical assistance. The cleaning of the stainless steel part must be done delicately using warm water. If you use soap or detergent make sure that these do not contain abrasive products and that they are recommended for cleaning stainless steel.