GANSHORN PowerCube-Ergo Service Manual

GANSHORN PowerCube-Ergo Service Manual

Cardiopulmonary function testing

Advertisement

GANSHORN Medizin Electronic GmbH
Service Manual Ref.No. 03 140 0 046
PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012
Preface, page 1 of 8
PowerCube-Ergo
Cardiopulmonary function testing
Service Manual
Ref.No. 03 140 0 046, rev.02
Valid for PowerCube-Ergo-SSO / CASE
- ENGLISH -
2004

Advertisement

Table of Contents
loading

Summary of Contents for GANSHORN PowerCube-Ergo

  • Page 1 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Preface, page 1 of 8 PowerCube-Ergo Cardiopulmonary function testing Service Manual Ref.No. 03 140 0 046, rev.02 Valid for PowerCube-Ergo-SSO / CASE - ENGLISH - 2004...
  • Page 2 Chapter 4: Circuit Diagrams and Board Layouts Chapter 5: Software Chapter 6: Troubleshooting, Checks and Adjustments Chapter 7: Spare Parts Appendix A: Allocation of Ergo-Parameters Appendix B: Working Procedure AA MTK 70_03 for PowerCube-Ergo- Appendix C: Checklist PP MTK 70_03 for PowerCube Ergo-SSO...
  • Page 3 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Preface, page 3 of 8 Preface Contact Addresses Warranty Copyright Documentation Valid for Related Documents Copyright Revision History General Notes Update Intended Use, Documentation Purpose, Target Group, and Safekeeping...
  • Page 4 The GANSHORN product has been employed in accordance with the intended use. GANSHORN is liable for the function capability, but not for the absolute lack of defects of its software programs. GANSHORN is only liable for the function capability of its software that is used with GANSHORN systems.
  • Page 5 The release number changes with every update for this documentation General Notes All GANSHORN documents correspond to the state of the underlying safety standards at the time of printing. All illustrations in this documentation are provided as examples only. They may not necessarily reflect your equipment setup or data displayed.
  • Page 6 The PowerCube-Ergo, using LF8, is not meant to be used for any purpose other than those named herein. If it is used for purposes that do not meet its intended use, this is regarded as an unauthorized...
  • Page 7 GANSHORN products may only be performed by GANSHORN or by an authorized GANSHORN partner.  The enclosures of GANSHORN devices may only be opened by GANSHORN or by an authorized GANSHORN partner.  If this device is modified appropriate inspection and testing must be conducted to ensure continued safe use of the device.
  • Page 8 “Start” Square brackets indicate keyboard keys, e.g. <Alt> = keyboard key labelled with “Alt” Equipment Identification Every GANSHORN device has a unique serial number for identification. The serial number “SN” appears on the device label. Equipment Symbols For equipment symbols and their meaning please refer to =>...
  • Page 9 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 1, safety regulations, page 1 of 8 Chapter 1: Safety Regulations Warning Notices Definitions Service Relevant Warning Notices General Warning Notices Electrical Warning Notices Hygiene Specific Warning Notices...
  • Page 10 REQUIREMENT FOR SERVICE PERSONEL Opening the PowerCube-housing as well as all changes, modifications, extensions, repairs, maintenance measures, and any other work on GANSHORN products including meteorological / safety checks may only be performed by GANSHORN or by an authorized GANSHORN partner.
  • Page 11 General Warning Notices WARNING INTENDED USE If LF8 and the PowerCube-Ergo are used for purposes other than its intended use, a safe operation of LF8 and the PowerCube-Ergo is not possible! GANSHORN is not responsible for any personal and physical damage that results from non-intended utilization of LF8 and the PowerCube-Ergo;...
  • Page 12 Chapter 1, safety regulations, page 4 of 8 DANGER INSTALLATION, UNINSTALLING All components of the GANSHORN device have to be switched off and disconnected from the mains for assembling and installation, as well as for uninstalling and disassembling. Installation and initial operation and any other work on GANSHORN products including meteorological / safety control may only be performed by GANSHORN or by an authorized GANSHORN partner.
  • Page 13 Do not use extension cords together with multiple sockets! Danger of life through electrical shock! If the GANSHORN device is used as a part of a system, it is not permitted to add other multiple sockets or extension cords to the system.
  • Page 14 ELECTROMAGNETIC COMPATIBILITY – SPARE PARTS WARNING It is not permitted to use any spare part for the GANSHORN device that has not been inspected and approved by GANSHORN. The use of accessories, transducers and wirings that are not mentioned in this...
  • Page 15 Read the hygiene instructions of these instruction manual and related documents thoroughly and comply with the detailed instructions given in these documentations => Instruction Manual PowerCube-Ergo, Chapter 8, Hygiene HYGIENE – ELECTRONIC PARTS DANGER Never clean electronic devices like the PowerCube module by submerging it in water or liquid solution.
  • Page 16 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 1, safety regulations, page 8 of 8...
  • Page 17 Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 2, system description , page 1 of 10 Chapter 2: System description Component Description PowerCube-Ergo Description of Elements, Indicators and Connections of the PowerCube-Ergo Functional Block Diagram Tubing Block Diagram...
  • Page 18 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 2, system description , page 2 of 10 Component Description PowerCube-Ergo The configuration of an ergospirometry system depends on the individual components, e.g.: Description Function PowerCube-Ergo Measurement module containing e.g.
  • Page 19 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 2, system description , page 3 of 10 Description of Elements, Indicators and Connections of the PowerCube-Ergo Pict.: PowerCube-Ergo with SSO, front Pos. Description Function Housing...
  • Page 20 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 2, system description , page 4 of 10 Pict. PowerCube-Ergo SSO-Sensor: tubing, rear Pict.: PowerCube-Ergo SSO-Sensor: connections, rear Pos. Description Function Flow – (blue) Socket for patient tubing from the pneumotach, patient side...
  • Page 21 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 2, system description , page 5 of 10 Functional Block Diagram Pict.: Functional block diagram PowerCube-Ergo Pos. Description Function Controller Module: MCU with firmware Control unit...
  • Page 22  through both gas analyzers (O2, CO2)  through the compensation vessel The gas sample leaves the PowerCube through the suction pump and the sound absorber Pict.: Block diagram PowerCube-Ergo, gas flow during an ergopirometry-measurement (Red: gas sample, measurement gas)
  • Page 23 The gas sample leaves the PowerCube through the pump and the sound absorber Pict.: Block diagram PowerCube-Ergo, gas flow during a ergo-calibration (gas calibration), calibration valve open (Red: gas sample from calibration gas. Dashed line: calibration gas)
  • Page 24 The suction pump sucks ambient air (gas sample) from the Cal-gas-out-socket The further gas circuit remains the same Pict.: Block diagram PowerCube-Ergo, gas flow during a ergo calibration (gas calibration), calibration valve closed (Red: gas sample from ambient air. Dashed line: calibration gas)
  • Page 25 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 2, system description , page 9 of 10 Technical Data PowerCube-Ergo General ® Software LF8 32 bit for Windows Classifications Device classification Active medical product, class IIa...
  • Page 26 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 2, system description , page 10 of 10...
  • Page 27 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 chapter 3, Disassembly, page 1of 10 Chapter 3: Disassembly Warning Notices Physical Overview General Tools and Accessories for PowerCube Maintenance How to Remove the Cover from the Base Assembly...
  • Page 28 REQUIREMENT FOR SERVICE PERSONEL Opening the PowerCube-housing as well as all changes, modifications, extensions, repairs, maintenance measures, and any other work on GANSHORN products including meteorological / safety checks may only be performed by GANSHORN or by an authorized GANSHORN partner.
  • Page 29 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 chapter 3, Disassembly, page 3of 10 Physical Overview The PowerCube housing consists of two metal shells. The base assembly contains all electronic parts of the PowerCube. The cover is connected to the base shell with a cable for potential equalization.
  • Page 30 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 chapter 3, Disassembly, page 4of 10 How to Remove the Cover from the Base Assembly The cover is secured on the base assembly with four screws; Access to these screws is gained from the lower surface of the unit.
  • Page 31 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 chapter 3, Disassembly, page 5of 10 How to Remove the Electronic Unit (Controller Module and Analog Module) 1) Remove the cover correctly from the base assembly 2) Unscrew the electronic unit holder by removing the four marked screws. Be aware, that two screws are located under the front panel;...
  • Page 32 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 chapter 3, Disassembly, page 6of 10 How to Split the Electronic unit into Electronic Unit Holder, Controller Module and Analog Module 1) Remove the electronic unit correctly from the PowerCube...
  • Page 33 After replacement of the suction pump please perform 1) Suction flow adjustment (see chapter 6, Troubleshooting, checks and adjustments) Pict.: PowerCube-Ergo, inner lateral: with compensation vessel (1) and suction pump (2). Other components: CO2-Analyser (3) and calibration valve (4) ►...
  • Page 34 To the OUT-socket of the CO2-Analyzer connect the thick tube coming from compensation vessel After replacement of the CO2-Analyser please perform: 1) CO2-Offset adjustment (see chapter 6, Troubleshooting, checks and adjustments) 2) CO2-Gain adjustment 3) Gas calibration Pict.: PowerCube-Ergo, inner lateral _____________________________________________________________________...
  • Page 35 To assemble the modules again perform the same steps backwards After replacement of the O2-Analyser please perform: 4) O2-Offset adjustment (see chapter 6, Troubleshooting, checks and adjustments) 5) O2-Gain adjustment 6) Gas calibration Pict.: PowerCube-Ergo, inner lateral: O2-Analyzer board (dashed line) with attachment bolts _____________________________________________________________________...
  • Page 36 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 chapter 3, Disassembly, page 10of 10 _____________________________________________________________________...
  • Page 37 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 4, circuit diagrams and board layouts, page 1 of 6 Chapter 4: Circuit Diagrams and Board Layouts Controller Module 1.3 – Board Layout Controller Module 1.3 – Circuit Diagram Analog Module 1.3 –...
  • Page 38 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 4, circuit diagrams and board layouts, page 2 of 6 Controller Module 1.3 – Board Layout Pict.: Controller Module 1.3 with connectors (red)
  • Page 39 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 4, circuit diagrams and board layouts, page 3 of 6 Controller Module 1.3 – Circuit Diagram F1: High breaking capacity: 1AT Pict.: Controller Module 1.3 with connectors (red)
  • Page 40 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 4, circuit diagrams and board layouts, page 4 of 6 Analog Module 1.3 – Board Layout Pict.: Analog Module 1.3 with connectors (red)
  • Page 41 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 4, circuit diagrams and board layouts, page 5 of 6 Analog Module 1.3 – Circuit Diagram Pict.: Analog Module 1.3 with connectors (red)
  • Page 42 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 4, circuit diagrams and board layouts, page 6 of 6...
  • Page 43 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 5, software, page 1 of 4 Chapter 5: Software Installation Updates for LF8 De-installation of LF8 De-installation of the BDE / the PDF Creator Allocation of External Ergospirometry Parameters...
  • Page 44 Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 5, software, page 2 of 4 Installation Please use the GANSHORN Installation Assistant for every installation. Before performing the installation, please ensure  The correct connection of all parts of the system ...
  • Page 45 Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 5, software, page 3 of 4 Updates for LF8 Please use the GANSHORN Installation Assistant for every update. We strongly recommend to perform a security backup of the actual LF8-installation folder before starting the update. INFORMATION Please keep care, that some files are overwritten that may be customized: *.frm, texte.*, messwert.*,...
  • Page 46 As there are different possibilities, these parameters have to be allocated depending on the complete system. For these settings, go into the “Ergospirometry-configuration” of the measurement program “ergospirometry” => Instruction Manual PowerCube-Ergo, Chapter 6.6, Ergospirometry  From the measurement program “Ergospirometry” click on edit ...
  • Page 47 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 1 of 16 Chapter 6: Troubleshooting, Checks and Adjustments General Trouble Shooting Flow Chart for Error Analysis „No Data Communication with PowerCube“...
  • Page 48 Chapter 6, Troubleshooting, Checks & Adjustments, page 2 of 16 Troubleshooting, Checks and Adjustments WARNING CARRYING OUT TROUBLESHOOTING Troubleshooting should only be performed by trained GANSHORN personnel or an authorised GANSHORN distributor. If a problem is to arise, please contact the Service personnel. Perform a calibration General The PowerCube was designed for simple and rapid repair of defective parts.
  • Page 49 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 3 of 16 Trouble Shooting Flow Chart for Error Analysis “No Data Communication with PowerCube” Pict.: Error message “No data communication with PowerCube”...
  • Page 50 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 4 of 16 Flow Chart for Error Analysis “Error while Determining the Base Line” For general information about the base line determination please refer also to =>...
  • Page 51 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 5 of 16 Flow Chart for Error Analysis “Invalid Volume Calibration – Drift ” For general information about the volume calibration please refer also to =>...
  • Page 52 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 6 of 16 Flow Chart for Error Analysis “Gas Calibration – Delay” DANGER DISCONNECT FROM THE MAINS BEFORE ANY REPAIR WORK Disconnect the PowerCube from the mains before starting any repair work.
  • Page 53 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 7 of 16 Flow Chart for Error Analysis “Gas Calibration–Offset for O2/CO2 too High/ Low”  Check the actual calibration factors for O2- and/or CO2-Offset Pict.: Calibration gas table, ergo calibration (gas calibration)
  • Page 54 Chapter 6, Troubleshooting, Checks & Adjustments, page 8 of 16 Flow Chart for Error Analysis “Generally Implausible Ergospirometry Values” For general information about Ergospirometry measurements and possible error sources please refer also to => Instruction Manual PowerCube-Ergo, Chapter 6.6, Ergospirometry, Improve the quality of Ergospirometry measurement! “Generally implausible Ergospirometry-values”...
  • Page 55 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 9 of 16 Checks and Adjustments Service program COM98IO Every LF8-installation performs automatically an installation of the COM98IO into the LF8-installation directory (main directory).
  • Page 56 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 10 of 16 How to select measurement channels for check and adjustment  Click on register card “Channels” = the list of all measurement channels is displayed on the screen...
  • Page 57 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 11 of 16 Overview: Measuring and switching channels of the PowerCube Ergo Measurement Signal Channel Ambient pressure Temperature PF1 (Flow)
  • Page 58 REQUIREMENT FOR SERVICE PERSONEL Opening the PowerCube-housing as well as all changes, modifications, extensions, repairs, maintenance measures, and any other work on GANSHORN products including meteorological / safety checks may only be performed by GANSHORN or by an authorized GANSHORN partner.
  • Page 59 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 13 of 16 Layout Analog Module 1.3 Offset-PF1 Gain-PF1 R132 Gain-O R131 Offset-O Offset-CO Offset-O Ambient Pressure Pict.: Analog Module 1.3 with pressure transducer (green) and potentiometer (red)
  • Page 60 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 14 of 16 Layout Controller Module 1.3 Pict.: Controller Module 1.3...
  • Page 61 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 6, Troubleshooting, Checks & Adjustments, page 15 of 16 Adjustment of the O2-Analyzer Preparation  Connect patient tube correctly to PowerCube as for a gas calibration ...
  • Page 62 For details of the installation and adjustment of the calibration gas supply please refer to => Instruction Manual PowerCube-Ergo, Chapter 5, Calibrations and tests, Ergo calibration (O2/CO2)! Appendix: Customer information Measurement and calibration gas!
  • Page 63 2044244-036 Internal connection cable RS232 (KP7002) Internal tubes 2044244-023 Internal flow-tubing set (SP7001) for PowerCube with pneumotach 2044244-024 Internal gas calibration tubing set (SP7006) for PowerCube-Ergo A1, B1 2044244-025 Internal measurement tubing set ergospirometry (SP7025) for PowerCube-Ergo-SSO Other spare parts 2044244-026 Complete housing, GE-health for PowerCube-Ergo-SSO, (incl.
  • Page 64 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Chapter 7, Spare Parts, page 2 of 2...
  • Page 65 GANSHORN Medizin Electronic GmbH Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Appendix, page 1 of 2 Appendix Appendix A: Allocation of Ergo Parameters Appendix B: Working Procedure AA MTK 70_03 for PowerCube Ergo-SSO Appendix C: Checklist PP MTK 70_03 for PowerCube Ergo-SSO...
  • Page 66 Service Manual Ref.No. 03 140 0 046 PowerCube-Ergo-CASE_ENG_rev.02, 23.11.2012 Appendix, page 2 of 2 Appendix A: Allocation of Érgospirometry Parameters Ergospirometry configuration, register card hardware: settings for PowerCube-Ergo with PC- ECG, if the complete system (including ergometer / treadmill) is controlled by the ECG Parameter ErgoScope...
  • Page 67: Table Of Contents

    Working procedure AA MTK 70_03 Ambit: Ganshorn Medizin Technical Support Electronic GmbH Working procedure for PowerCube Ergo /SSO Rev E Revision: Rev01 30.11.2012 Table of contents Application area: ............................2 Basic remark: ............................2 1. Examinee .............................. 2 2. Check conditions ..........................2 3.
  • Page 68: Application Area

    Working procedure for PowerCube Ergo /SSO Rev E Revision: Rev01 30.11.2012 Application area: PowerCube-Ergo with Art.No: 033370210, 033370238 For options further checks might become necessary Basic remark: This check procedure must be carried out within a preventive maintenance and as checkout procedure after repair.
  • Page 69: Electronics

    Working procedure AA MTK 70_03 Ambit: Ganshorn Medizin Technical Support Electronic GmbH Working procedure for PowerCube Ergo /SSO Rev E Revision: Rev01 30.11.2012 8. Electronics Functional check of the switching and measurement channels in COM98IO: Check the pressure sensors with pos. und neg. pressure; the higher differences have to be noted.
  • Page 70 Working procedure AA MTK 70_03 Ambit: Ganshorn Medizin Technical Support Electronic GmbH Working procedure for PowerCube Ergo /SSO Rev E Revision: Rev01 30.11.2012 Analog-Modul 1.3 O-PF1 G-PF1 R132 G-O2 R131 O-O2 O-CO PF1 sensor Amb. Press Controller-Modul 1.2; 1.3 Page 4 von 7...
  • Page 71: Ergo Suction Flow

    Close the LF8 or COM98IO and start PowerTool V1.3: the windows GANSHORN-Hardware (Control), Switch (Switch) and Scan Timing (View) must be screened. Select in window GANSHORN-Hardware „PwC“ and the used COM port. Start the PwC via button Activate in window Switch Channel 0.
  • Page 72: Co 2 Gain (With Ergo-Calibration Gas)

    Working procedure AA MTK 70_03 Ambit: Ganshorn Medizin Technical Support Electronic GmbH Working procedure for PowerCube Ergo /SSO Rev E Revision: Rev01 30.11.2012 Gain (with Ergo-calibration gas) Remark: Not applicable for PwC-Ergo with option Cardiac output Activate the switches for the suction pump Ergo and the Cal. valve and check the indicated value in COM98IO.
  • Page 73 Working procedure AA MTK 70_03 Ambit: Ganshorn Medizin Technical Support Electronic GmbH Working procedure for PowerCube Ergo /SSO Rev E Revision: Rev01 30.11.2012 ELECTRICAL SAFETY CHECKS Electrical safety checks must be performed in a period of 12 month and after repair.
  • Page 74 Ambit: Checklist PP MTK 70_03 Ganshorn Medizin Technical Support Electronic GmbH Checklist for PowerCube Ergo /SSO Rev E Revision : Rev01 30.11.2012 1. Examinee Date: Examiner: System: Company: Accessories Options: Last check: Reason of this check: Next check: Preventive Maintenance Check after Repair This check is only to be carried out from authorized persons (MPBetreibV §11)!
  • Page 75 Checklist PP MTK 70_03 Ambit: Ganshorn Medizin Technical Support Electronic GmbH Checklist for PowerCube Ergo /SSO Rev E Index: Rev01 30.11.2012 6. Visual checks n..a. n.OK Tubes and connectors (not bent, connected tightly, not damaged) Gas drying tube (not bent, connected tightly, not damaged) Pneumotach “Blendenspirozeptor”...
  • Page 76 Checklist PP MTK 70_03 Ambit: Ganshorn Medizin Technical Support Electronic GmbH Checklist for PowerCube Ergo /SSO Rev E Index: Rev01 30.11.2012 ELECTRICAL SAFETY CHECKS: Perform electrical safety checks when indicated. Record measurement values in your debrief. NOTE: The following values apply to 120/240VAC...
  • Page 77 Checklist PP MTK 70_03 Ambit: Ganshorn Medizin Technical Support Electronic GmbH Checklist for PowerCube Ergo /SSO Rev E Index: Rev01 30.11.2012 Patient leakage µA current Mains on applied part Forward Pass/Fail 5000µA polarity Neutral closed Reverse Pass/Fail 5000µA polarity Neutral...
  • Page 80                                         Ganshorn Medizin Electronic GmbH  Industriestr. 6‐8  D‐97618 Niederlauer  Germany    Tel.  +49 9771 6222‐0  Fax  +49 9771 6222‐55                       ...