Page 1
MODEL ADH NETCOM ® AUTOMATIC AIR DEHYDRATOR WITH ETHERNET ® NETCOM™ AC NEMA AUTOMATIC AIR DEHYDRATOR POWER FILTER MODULE REPLACEMENT PROCEDURE Replacement Kit Part Number 24087 Document Part Number 24100 South Bend, Indiana USA networketi.com ADH INSTRUCTION MANUAL | PART NO. 24100...
SAFETY INFORMATION AND WARNINGS Abnormal Odor or Smoke Rack Mounting In the event of smoke or a burning or Before and after rack mounting the abnormal odor, immediately interrupt ADH NETCOM, ensure that the rack power to the ADH NETCOM with the is stable.
Page 3
• Small flat blade screwdriver This procedure addresses the removal and • Nut driver replacement of the Power Filter Module in an ADH NETCOM AC NEMA Automatic Air • Tubing wrench or vacuum tube pliers Dehydrator. It is recommended to read •...
Page 4
POWER FILTER MODULE REMOVAL AND REPLACEMENT To replace the Power Filter Module (23563) Disconnect in an ADH NETCOM AC NEMA Automatic both ends, Air Dehydrator, perform the steps below. then remove orange ethernet cable. Loosen both captive screws, Shut off machine power by then disconnect connector.
Page 5
Connect the electrical leads in the Note how the five electrical leads are corresponding locations on the new connected to the existing Power Filter Power Filter Module from which they Module, then use a needle nose pliers were removed on the old module. to carefully disconnect the leads from Refer to the following tables.