Surpass HPIX Series Operation Manual

Fluorine resin type pressure sensor

Advertisement

Quick Links

3UZX418145E-06 1/9
Fluorine Resin Type Pressure Sensor
HPIX
HPSX
Operation Manual
Surpass Industry Co., Ltd.
2020/5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPIX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Surpass HPIX Series

  • Page 1 3UZX418145E-06 1/9 Fluorine Resin Type Pressure Sensor HPIX HPSX Operation Manual Surpass Industry Co., Ltd. 2020/5...
  • Page 2: Read Before Use

    Surpass Industry about errors,  Use the product only as intended, and only omissions, or any other points of doubt. as directed in this manual.
  • Page 3: Product Description

    3UZX418145E-06 3/9 Product Description <Applications> PTFE Pressure Sensors can be used as semiconductor manufacturing devices or as pressure monitor/process control devices for chemical processes, high-purity fluids, etc. <Features> ● All models comply with the RoHS directive. ● The wetted part is fully made of fluorine resin allowing it be used with a variety of chemicals. ●...
  • Page 4: Outer Dimensions

    3UZX418145E-06 4/9 Outer Dimensions <HPIX> <HPSX> Cable Cable Control unit Control unit Case Base Case Connector Body Connector Body G Model HPIX-12 (39) (50) HPIX-13 (45.5) (56.5) HPIX-14 (47) (58) HPIX-16 (62) (73) Names and Functions on the Control Unit Zero Adjust button LED lamp ●Used to perform zero adjust .
  • Page 5 3UZX418145E-06 5/9 Mounting and Connecting the Connector Parts <Inline type> If you wish to anchor your Pressure Sensor, always use the mounting holes in the base. In order to install connector parts correctly, always refer to the relevant catalog or operation manual issued by the connector manufacturer.
  • Page 6: How To Use

    3UZX418145E-06 6/9 Wiring Observe these precautions to connect the leads correctly. CAUTION  Never do wiring work when power supply is on. Doing so may cause electrical shock.  Do not pull or bend the cable forcibly. It may cause breakage of the cable, electrical shock, or fire. In addition, pulling the cable forcibly rotates the case, which may result in the damage to the product.
  • Page 7 3UZX418145E-06 7/9 How to Do Zero Adjust  Using the Zero Adjust button  Zero adjust by external input (1) Make sure that your Pressure Sensor is (1) Make sure that your Pressure Sensor is opened to the atmospheric state. opened to the atmospheric state.
  • Page 8: Maintenance And Inspection

    3UZX418145E-06 8/9 Maintenance and Inspection The Pressure Sensor should be inspected regularly, about twice a year depending on the usage. During the regular inspection, check the - appearance - corrosion, clogging, leakage, etc., from the connector parts. The Pressure Sensor should be flushed periodically if using liquids that crystallize easily. <Safety Notes on Maintenance and Inspection>...
  • Page 9 3UZX418145E-06 9/9 Notes on Warranty The warranty runs for one year after the day when Surpass Industry products are delivered from Surpass factory in Japan. In case Surpass Industry should agree in writing that the defects in performance or material were caused by faulty design or workmanship of Surpass Industry, replacement products will be supplied free of charge.