If in any doubt please do not touch this equipment. Please contact Bss Industrial or your reseller for additional advice, information and guidance. PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 2...
To the best of our knowledge this information is the sum of our current findings and experience. We reserve the right to make technical changes subject to the future development of the BOSS™ product referred to in this publication. Hence no rights may be derived from technical data, descriptions and illustrations. Technical pictures, drawings and graphs do not necessarily correspond to the actual assemblies or parts as delivered.
Consider the implications of errors and incorrect set-up conditions carefully! Disregarding these warnings may lead to: • serious personal injury, • overloading of individual components and damage, • impair the unit’s function. PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 4...
The product may not be used if circumstances are not in line with our conformity statement, or if the delivery proceeded incorrectly in any other manner. PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 5...
PeRmItted PRessuRe &/oR temPeRAtuRe LeveLs Equipment used in combination with the BOSS™ PD-Monitor™ must guarantee that the permitted operating temperature and the permitted medium temperature (heat transfer medium) cannot be exceeded. Excess pressure and temperature may lead to component overload, irreparable damage to components, loss of function and, as a result, to severe personal injury and damage to property.
12 months. mAIntenAnCe & RePAIR These services may only be carried out when the BOSS™ PD-Monitor™ is shut down. The BOSS™ PD-Monitor™ equipment must be taken out of service and guarded against unintentional re-starting until the maintenance work is finished.
• Use in inappropriate system designs and environments. • Use of non-permitted or inappropriate installation materials. PRoduCt desCRIPtIon The BOSS™ PD-Monitor™ is a packaged pressure differential monitoring unit. It is a fully assembled, factory tested, wall-mounted unit incorporating: • 2No 4-20 milliamp pressure transducers.
LAyout of vARIous InstALLAtIons This diagram is for visual purposes only and does not signify exact pipework layouts or valve requirements. ComPonent LIst PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 9...
PRInCIPLe The BOSS™ PD-Monitor™ is designed to be a self-contained pressure differential monitor and alarm signalling device. It has a dedicated up-stream pressure transducer and down- stream pressure transducer connection to a sealed or open vented system. As system...
InstALLAtIon BASIC INSTALLATION REQUIREMENTS The BOSS ™ PD-Monitor controller unit (item 1) is to be positioned and fixed to a sturdy wall / frame as close as possible to the item of plant to be monitored. The pressure transducers need to be connected either side of an item of plant which requires the pressure differential to be monitored.
Page 12
Sealed system water. • Hydraulic equipment. It is essential to ensure the environment that this equipment is installed in is safe to work in and is free from trip hazards. PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 12...
Controller will return to its last set ® operating mode once power has been restored. Ensure the power supply to the BOSS™ PD-Monitor™ is 230V ~ 1 N PE 50Hz via a suitable Fused Spur. The power supply to the BOSS...
4. Activation The BOSS™ PD-Monitor™ can now be activated by pressing the Isolator Switch from the ‘Off’ position to the ‘On’ position. The VEXO iX-2 Controller will now scroll the following...
Page 16
® 2. SETTING PARAMETERS 3. ALARM CONDITIONS If the PD-Monitor detects pressure outside of set parameters during normal operation, fault condition will be initialised. • In alarm conditions, the internal buzzer will sound on the controller. This can be muted by pressing the mute (button 3).
0 = N/C 1 = N/C Sensor Minimum Pressure 0 Bar 0.0 – 10.0 Bar Sensor Maximum Pressure 10 Bar 0.0 – 10.0 Bar ID Number Pump Hours Alarm Count PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 17...
The destination of and further processing of the construction components should be carried out in agreement with the relevant waste management service provider. PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 18...
200mm from the front of the unit to enable unhindered opening of the front service panel. 1.8m FLYING CABLE Ø8 PACKARD PLUG 1/4" BSP THREAD PRESSURE SENSOR MOUNTING HOLES PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 19...
Richard Cowley, Technical Director Vexo International (UK) Ltd. 6 The Granary Building, Millow Hall Farm, Millow, Biggleswade, Bedfordshire, SG18 8RH T: 01767 500 150, Registered in England & Wales No: 072 05096 PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 20...
Page 21
Boss WAteR tReAtment PRoduCts PD-Monitor Operation & Maintenance Manual (V1.0 Feb 2018) BOSS Page 21...
Page 24
BOSS™ PD-Monitor is distributed exclusively by BSS Industrial, BOSS Court, 7 Barton Close, Grove Park, Leicester, LE19 1SJ www.bssindustrial.co.uk Tel: 0116 245 5940 PD-Monitor, X-PO10 and X-POT are trademarks of VEXO International...