iVECTOR (TYPES BC, BN, FC, FN)
INSTALLATION & OPERATING MANUAL
Product Serial Number:
Please leave this manual with the end user
Part Number: P25M1387
heatingthroughinnovation.

Advertisement

loading
Need help?

Need help?

Do you have a question about the iVECTOR BC and is the answer not in the manual?

Questions and answers

Summary of Contents for Ke Kelit iVECTOR BC

  • Page 1 iVECTOR (TYPES BC, BN, FC, FN) INSTALLATION & OPERATING MANUAL Product Serial Number: Please leave this manual with the end user Part Number: P25M1387 heatingthroughinnovation.
  • Page 2: Table Of Contents

    Contents Safety Information Controls (types BC & FC only) Installation Troubleshooting Water Connection Appendices Electrical Connection 1.0 Safety Information iVECTOR MUST NOT be installed in a bathroom. WARNING: All iVECTOR models must be earthed. DO NOT cover or obstruct the air inlet or outlet grille. This appliance can be used by Children aged from 3 years and less children aged from 8 years and...
  • Page 3: Installation

    iVECTOR 2.0 Installation For the correct installation of this unit it is essential that Check the location where the product is to be installed, the wall fixing is carried out in such a way that it is suitable for surface must be flat and clearances shown in FIG 2 must be intended use and predictable misuse.
  • Page 4: Controls (Types Bc & Fc Only)

    iVECTOR 5.0 Controls Note: When increasing the heating set-point beyond the cooling set Similarly, when decreasing the cooling set point below the heating point, the cooling set point will increase in line with the heating set-point, the heating set point will decrease in line with the cooling set-point.
  • Page 5 iVECTOR 5.0 Controls (continued...) Operating Modes Use ( ) and ( ) keys to choose from the following parameters. A function is selected when the icon is surrounded by Availability Function Description Adjustment Easy Full Control Operation Setup Control Operation Setup The unit must be programmed for operation Scroll to the Fixed Fan mode , and then...
  • Page 6 iVECTOR 5.0 Controls (continued...) Installer’s Set-up Parameters To access the installation parameters menu, scroll to AUTO the (+) and (-) keys to adjust the value. Then, press (OK) to (while in full mode), then press (OK) for 10s. Use ( ) and ( confirm.
  • Page 7: Troubleshooting

    iVECTOR 5.0 Controls (continued...) Pressing (+) will set the hour as a Comfort Mode temperature, User Program Menu while pressing (-) will set the hour as a Night Set-back Select U1-U4 (FIG 9, B) using the (+) and (-) keys and press (OK) temperature.
  • Page 8 iVECTOR Appendix Tools required: † † 4 pipe only Fig 1. Fig 2. 154.3 141 [4P] 125 [2P] Fig 3. Fig 4. * Type FN/FC only 2P/4P † ◆ Dimensions (mm)
  • Page 9 iVECTOR Appendix (continued...) (A = 800/1000/1200/1400/1600) (A - 297) A - 297 239** Fig 5. / Abb 5. / Rys 5. * Type FN/FC only ** Type BN/BC only...
  • Page 10 iVECTOR Appendix (continued...) Fig 6. Fig 7. BN / FN BC / FC Control Board Power Board Power Supply Cable Entry Points EC Adaptor Terminal Block Motor Fig 8.
  • Page 11 iVECTOR Appendix (continued...) Wire route channel Possible wire route SECTION A-A 1.5 m 1.2 m Type BC/FC only Fig 9.
  • Page 12 iVECTOR Appendix (continued...) 1. Type BC/FC only Fig 10a.
  • Page 13 iVECTOR Appendix (continued...) 2. Type BN/FN only Fig 10b.
  • Page 14 iVECTOR Appendix (continued...) Fig 10c.
  • Page 15 iVECTOR Appendix (continued...) Fig 10d.
  • Page 16 iVECTOR Appendix (continued...) Fig 10e.
  • Page 17 iVECTOR Appendix (continued...) Wiring Diagrams’ Key Power Supply Voltage Free Terminals (Valve Switching) EC Adaptor Output to Slave unit (Optional) Motor Teminal Block Air Sensor Terminal Block Power Board Input from Master unit (Optional) Control Board Air Sensor 220-240V AC Output Water Sensor 24V DC Output Water Sensor (4P Only)
  • Page 18 iVECTOR Appendix (continued...) Performance Data 2-Pipe (Type BC/BN/FC/FN) Heat Output (Watts) Cooling (Watts) Model Condition 7-12-27 Flow Speed* ΔT20 ΔT25 ΔT30 ΔT35 ΔT40 ΔT45 ΔT50 (l/h) Total Sensible 1146 1355 1567 1781 1997 2- 080 1360 1733 2113 2499 2889 3284 3682 1648...
  • Page 19 iVECTOR Appendix (continued...) ) Technical Information Model Speed iV60x080 iV60x100 iV60x120 iV60x140 iV60x160 Nominal Height (mm) Dimensions Depth (mm) Length (mm) 1000 1200 1400 1600 Sound Pressure (dBA) 20.9 22.5 20.9 21.1 21.9 (at 2.5m) 39.9 42.0 41.2 44.9 43.3 Sound Levels Sound Power (dBA) 33.8...
  • Page 20 heatingthroughinnovation.