Page 1
Nothing contained in this publication should be viewed as an endorsement by CityGrow Energy Systems Limited of any particular manufacturer’s products.
Page 2
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage”...
Table of content Introduction ....................1 Understanding the product – CG102IR-AC ............ 2 Understanding the product – CG100HTH-IR ..........4 Configuration of CG100HTH-IR and CG102IR-AC ........... 6 4.1. Apply network information to the devices ..........6 4.2. Pairing the CG100HTH-IR and CG102IR-AC .......... 6 4.3.
1. Introduction Thank you for choosing CityGrow’s product. The Air-Conditioner IR Control Kit consists of CG100HTH and CG102IR-AC. CG100HTH-IR is a wall-mounted thermostat control plate for controlling the temperature and setting. CG102IR-AC should be mounted close to the air- conditioner for transmitting the air-conditioner infrared signal.
2. Understanding the product – CG102IR-AC Face cover IR lens Main unit (Rear view) Main unit (Front view) IR Learn LED Reset Wall mounting DC Jack hole IR TX LED Function (Test) IR extension cable Programming connector connector Stand Mounting hole for ceiling mount...
Page 6
Dimension of CG102IR-AC Main unit 87mm 87mm 22mm Stand 28mm 100mm...
3. Understanding the product – CG100HTH-IR Frame Control plate Control plate (front view) Temperature display window (rear view) Control button Model number plate Programming port Connector to the Bracket Reset button Bracket Bracket Metal clip for fixing the control plate...
Page 8
Dimension of CG100HTH-IR CG100HTH-IR 85mm 28mm...
Power up the CG102IR-AC with the AC power adaptor. Hold any button on the CG100HTH-IR then press and release the reset button at the same time to perform Pairing. If the pairing process is successful, “OK” will be shown on the LED display of the ...
Page 10
Step 2: Download the “CG102IR Planner 1.2” software from the link below and install the software onto the computer. Link to download the “CG102IR Planner 1.2” software: https://citygrowsys.com/en/download/#software-download Install the “CG102IR Planner 1.2” software on any Windows PC. Connect the CG102IR-AC to the PC with the CG101UTU cable (NOT INCLUDED) through the CG102IR-AC USB port.
Page 11
Step 3: Start a “New Project” on the CG102IR Planner 1.2 software. Step 4: Select the correct “Port” and click “Connect” to connect the CG102IR-AC with the PC.
Page 12
Step 5: “Status: Connected” is shown, the connection is successful. Step 6: Now place the original IR remote controller in front of the CG102IR-AC IR learning head, the best distance is 50mm from the IR learning head. Step 7: Option 1 – Learn (Auto) On the Functions List of the CG102IR Planner 1.2 PC user interface, choose “Learn (Auto)”...
Page 13
Option 2 – Learn (IRSI) User can also choose “Learn (IRSI)” on the CG102IR Planner 1.2 PC user interface to perform IR signal learning manually. Step 8: Following the instruction and press the button on the remote controller to learn the code.
Page 14
Step 9: When the learning process is successful, you will see the notification as below. Repeat Step 7 and Step 8 to learn all the IR codes onto the CG102IR-AC. You can store up to a maximum of 60 IR codes onto the CG102IR-AC. Step 10: When all the learning processes are completed, please save the Project file with filename.
Page 15
Step 11: Optional (Personalize the Description on the IR table) User can personal the Description of the IR codes on the IR table. Choose an IRSI and double click, now you can personalize the Description of the learnt IR code on the table.
4.4. Guide to Learn (IRIS) the air-conditioner IR signals Learning “OFF” signal Cover the IR head of the remote controller and press the Power button to turn the air- conditioner to “ON” status. Select the “0” row on the IR table to learn the “OFF” onto the “0” row. ...
Page 17
Now place the remote controller in front of the CG102IR-AC, make sure the IR emitter aligned with the receiver of the CG102IR-AC. Press the Mode button of the remote controller to run the “FAN LOW” mode. Learn the “FAN LOW” signal. ...
Page 18
Table 1 IR Signal learning table sample IRSI Function FAN LOW FAN MID FAN HIGH 16°C FAN LOW 16°C FAN MID 16°C FAN HIGH 17°C FAN LOW 17°C FAN MID 17°C FAN HIGH 18°C FAN LOW 18°C FAN MID 18°C FAN HIGH 19°C FAN LOW 19°C FAN MID 19°C FAN HIGH...
This product is designed for residential and commercial use, for indoor use only. WARNING! Install in accordance to all national and local electrical codes. IMPORTANT! CityGrow® is not liable for any damage incurred with the misuse of the product. IMPORTANT! Pre-setup can only be done by a professional technician or manufacturer agent.
Page 20
STEP 1: IMPORTANT! Turn off main power at the main switch board. STEP 2: Connect the main power cable to the Live and Neutral terminals of the CG101AD Mini Power Supply. The Live (Brown) wire and Neutral (Blue) wire should be connected to the CG101AD Mini Power Supply.
Page 21
STEP 4: Plug the DC plug into the DC jack input of the CG102IR-AC, plug the IR extension cable into the CG102IR-AC IR port on the rear side. Retrofit the CG102IR-AC into the wall box and mount it onto the wall by fastening the two screws at the rear of the switch box. Wall box installation diagram Cover DC plug from provided...
IR Learning Signal process is completed, and the installation completed properly. When “OFF” mode is enabled, press and release the ‘ON’ button of the CG100HTH-IR, to toggle between “COOL”, “DRY” and “FAN” Mode through the CG102IR-AC. When the air-conditioner is in “DRY” mode, the temperature and fan speed buttons on the ...
7. Specification Item CG100HTH-IR Thermostat CG102IR-AC ZigBee IR Transmitter Power supply Powered by CG101AD external DC6V Mini Power Supply IR transmission range IR transmission angle +/- 60 degree Best IR learning distance 15 to 80mm from the IR learn LED...
Need help?
Do you have a question about the CG100HTH-IR and is the answer not in the manual?