Download Print this page

Dynamic Dynatrap 3 Owner's Manual

Indoors insect trap

Advertisement

Available languages

Available languages

Quick Links

OWNER'S MANUAL
FLYING INSECT TRAP
MODEL: DT3001N
Thank you for purchasing the
DYNATRAP® flying insect trap!
IMPORTANT SAFETY INSTRUCTIONS
WARNING, When using electric appliances, basic precautions should always be followed, including the
following:
- To
disconnect, turn all controls lo the off ('O") position, then remove plug from outlet.
- Unplug from outlet when not
in
use and before servicing or cleaning. Do not use outdoors.
- To
reduce the risk of electrical shock, do not put appliance in
water
or other liquid.
- This appliance is provided with double
insulation.
Use only identical replacement
parts.
See instructions for Servicing of Double-Insulated
Appliances.
- Connect only to o circuit that is protected by o ground-foul! circuit-interrupter
(GFCI).
INSTRUCTIONS FOR DOUBLE-INSULATED, CORD-CONNECTED APPLIANCES:
In a double-insulated appliance, two systems of insulation ore provided instead of grounding. No
grounding
means is provided
on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated
appliance requires extreme core and knowledge of the system, and should be done only by qualified service
personnel.
Replacement ports for a double-insulated appliance must be identical to those ports in the
appliance.
IMPORTANT SAFETY INSTRUCTIONS
Please read these instructions before using the DYNATRAP® Insect Trap and keep for future reference.
l.
Always turn unit off and disconnect plug before servicing, cleaning, or changing bulb.
2.
Do not position the unit near heat, gos, oil or other flammable
materials.
3. Place product out of reach from
children.
4. Never operate this product if it hos a damaged cord or plug, ii it is not working properly, ii it hos been dropped or
damaged, or if it hos been dropped into
water.
5. This product is equipped with 2-conductor cord and 2-prong polarized plug as
a
safety feature. This plug will fit in a
polarized outlet only one way. If the plug does not fully lit in the outlet, then reverse the plug. If it still does not fit,
then contact a qualified
electrician.
To reduce the risk of electrical shock, only plug into a properly installed outlet.
Do not attempt to defeat this safety feature.
6.
Do not insert fingers or any foreign objects into the unit while ii is connected to an electrical outlet.
7.
Collected insects within the unit may contribute to fire, so clean insects from the unit
frequent~.
8. Do not clean this product with water
spray.
Do not place where it con foll into water, or near flammable materials.
9.
Do not touch fan while in
motion.
l 0. Do not abuse cord--never carry or hong
unit
by cord or yank it to disconnect from receptacle. Keep cord away from heat,
oil, or sharp
edges.
11. Use only extension cords that hove plug and receptacles that match the product
plug.
Replace or repair damaged cords.
INSTALLATION & OPERATING INSTRUCTIONS
1.
Unpack Unit. Save carton for off-season storage (if
needed).
2.
Plug cord into on outlet or UL listed extension cord as described in "IMPORTANT SAFEIY
INSTRUCTIONS".
3.
Hold the Power switch on the side of the revolving rotation
door.
Twist the unit lo the
"Power ON" position. When you hear a 'click", the machine is turned on. For best
catch
results
leave unit on at all times, except when cleaning or
servicing.
4.
Catch role activity will be higher al night. For best catch results ii is recommended lo
keep the unit away from competing light sources. Intended for household use only.
CLEANING
Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient
operation.
1.
Be sure to clean the unit once per week
2.
To
clean, hold the switch on the revolving rotation door and turn it to the "POWER OFF" position. After hearing the "click",
the machine is turned
off.
Unplug the unit.
3. For weekly cleaning, remove the screw securing the retaining cage and then twist the cage
clockwise.
Remove any buildup from
the inside of the retaining cage and fan with a brush
(included).
4.
When replacing the retaining cage - DO NOT press/push against the screen windows.
REPLACING BULB
The light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure optimal
UV effectiveness. Even though the bulb's light may be visible to you, its ability to attract insects diminishes over
time.
1.
Turn power switch to "off" position. UNPLUG UNIT, and allow bulb to cool before replacing.
2.
Remove the screw securing the retaining cage and then remove the retaining cage by twisting the cage clockwise. Turn the
unit upside
down.
3.
Remove the four screws securing the fan housing to the light
housing.
After removing the screws, gently pull the fan housing
away from the light housing. Using a soft brush, remove dirt and debris from the light housing. Once the cleaning process has
been completed, untighten the screw securing the base of the light bulb to the light
housing.
Slide the metal bracket to the
side.
Cover the bulb with a cloth to protect your finger and hand. Grasp the bulb (with your hand and fingers protected by the cloth)
and gent~ pull the bulb from the socket.
4.
Remove any debris from the lamp socket with a brush before inserting the new bulb. Replace the metal plate over the base of
the bulb and tighten the retaining
screw.
5.
Align the screw holes in the fan housing with the screw holes in the lighting unit and tighten the screws to the base of the
lighting unit.
6.
Replace the retaining cage at the bottom of the unit.
Replacement fluorescent bulbs con be found at your local retailer or con be ordered dire~ from
~
IC.
by colling
1-877-403-TRAP (8727) or visiting www.dynotrop.com
HOW THE DYNATRAP® INSECT TRAP WORKS
Flying insects ore ottrocted to the unit by UV light and CO2 that is
generated by the photo-catalysis between the UV lamps and spe-
cial TI02 coating. The fan then pulls the insects into the screened
base, trapping them until they dehydrate and die. The base con be
removed, allowing the contents to be periodically emptied into
the
trash.
The see-through screen shows the insects trapped in the
comportment, alerting you when the net needs to be
emptied.
RETAINING
--I-lilt
CAGE
TI02 COATED
SURFACE
TROUBLESHOOTING
Problem:
Possible cause:
Correction:
Bulb does not illuminate
1. No electrical power.
1. Check plug and receptacle and fuse or circuit breaker.
and fan does not
spin.
2.
Check to make sure power is switched to the "on"
position.
Bulb illuminates, but fan
1. Shorted
fan.
1. UNPLUG UNIT: Examine fan to see that it is free from
does not spin.
foreign material, dirt or build-up of dead
insects.
Clean unit as
in "CLEANING" section.
Fon spins, but bulb does
1. Bulb not seated
1. Check all sockets for proper bulb seating and alignment.
not illuminate.
properly.
2. Replace bulb if needed following instructions under 'Replacing
2.
Burnt out bulb.
Bulb".
LIMITED WARRANTY
DWtUft'IC.
warranties to the original purchaser that this product is free from defective materials and
workmanship. This warranty is limited to remedy any defective part for a period of one year from date of
original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply
to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in
force.
This warranty does not apply
if
this unit is purchased outside the United States, excluding Canada
and Mexico. In no case shall
~
-be liable for any accidental, punitive, consequential, or any other
damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some
states do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and you may also have other rights
that vary from state to state.
PARTS
&
ACCESSORIES AVAILABLE
PART
DESCRIPTION
41050
41052-DT300IN
41053·DT300IN
7-Wott Replacement Fluorescent Bulb
(1
piece)
Fon Blade and DC Motor Ultra-Long Life Replacement
Retaining Cage
Dynamic Solutions Worldwide, LLC
12247 W
.
Fairview Ave. Milwaukee,
WI
53226
Phone:
414-431-2819
Toll
free: 1-877-403-TRAP (8727)
Toll
free fox: 877-403-3293
Email: dynatrapinfo@dsw-llc.com
Visit
us
online al www.dynalrap.com
©
Dynamic Solutions Worldwide,
LL(
SAVE THESE INSTRUCTIONS
lntertek

Advertisement

loading

This manual is also suitable for:

Dt300in