OPERATION MANUAL
Saluber PD23E-20
Thanks for choosing this dehumidifier, before using. Please read this
manual carefully, and follow this manual strictly. Please keep it
properly after reading for future reference.
DEHUMIDIFIER

Advertisement

Table of Contents
loading

Summary of Contents for LAMINOX Saluber PD23E-20

  • Page 1 OPERATION MANUAL Saluber PD23E-20 Thanks for choosing this dehumidifier, before using. Please read this manual carefully, and follow this manual strictly. Please keep it properly after reading for future reference. DEHUMIDIFIER...
  • Page 2: Table Of Contents

    DIRECTORY IMPORTANT SAFEGUARDS SPECIFICATIONS GENRERAL DESCRIPTION DEHUMIDIFIER CONTROL PANEL CONTROL PANEL Saluber PD23E-20 EMPTTING THE WATER TANK CONTINUOUS DRAINAGE OPERATION REPLACEMENT AND MAITENANCE OF AIR FILTER OTHER NOTICE CARE AND CLEANING FAULT CODE TROUBLE SHOOTING IMPORTANT NOTICE To prevent damage and voiding your warranty. Please place the unit in its right position for a minimum of two hours before operating.
  • Page 3: Saluber Pd23E-20

    Keep the appliance dry. Make sure no water on the top or the body. Do not unpin the plug when the appliance is working. Model No.: Saluber PD23E-20 If moving needed, please switch it off and unpin the plug. 20 L/Day(30℃RH80%) Dehumidify capacity: Allow a free space of 15 cm around air inlet of the appliance.
  • Page 4: Genreral Description

    CONTROL PANEL GENRERAL DESCRIPTION 1. Oscillation louver 3. Air outlet 2. Control panel P0WER 4. Lamp Starts or Stops appliance. Up key Down key MODE Control Select the functions of the unit for:AUTO Timer Lamp / HIGH / LOW / and FAN.
  • Page 5: Control Panel

    CONTROL PANEL EMPTYING THE WATER TANK Empty the water tank regularly when full, the air HUMIDITY SETTING dehumidifier turns off automatically and the tank full Press UP / DOWN key to select the desired relative humidity level, indicator is turned on. default relative humidity is 55%.
  • Page 6 GENRERAL DESCRIPTION CARE AND CLEANING 1.The machine uses the temperature range of 5℃ ~35℃ , please use the machine in this scope, (otherwise it will start the protection action, causing the machine automatically stop running.) 2. At room temperature at 5℃ and the absolute temperature of the environment is very low.
  • Page 7: Care And Cleaning

    CARE AND CLEANING Code Failure Room temperature (ambient temperature) sensor for short circuit Room temperature sensor open circuit Humidity sensor short circuit Humidity sensor open circuit Coil sensor short circuit Please clean filter once every After filtering the net, please Around the body or out of Coil sensor open circuit two weeks (not to use 40...
  • Page 8: Trouble Shooting

    TROUBLE SHOOTING When the following problems occur, please contact the local seller or customer service: 1) When the fuse breaks 2) When water or other dirt get's into the machine 3) When the power line or plug is abnormally hot. When you need to call the customer services Anything Wrong? ……, Please check your machine with the following steps...