Go Direct Blood Pressure is a non-invasive sensor that measures human blood
pressure. It measures systolic, diastolic, and mean arterial pressure via the
oscillometric method. Go Direct Blood Pressure can also report pulse rate and
display both individual pressure pulses and peak-to-peak pulse amplitudes. The
sensor indicator light provides immediate user feedback, letting students know
when blood pressure parameters have been reported. With both USB and
wireless capabilities, students can monitor blood pressure anywhere using
almost any device.
Go Direct Blood Pressure can be used in a variety of experiments, such as
Measuring and compare blood pressure and heart rate
l
Measuring how exercise changes blood pressure
l
Observing how the "fight or flight" response changes blood pressure
l
Note: Vernier products are designed for educational use. Our products are not
designed nor are they recommended for any industrial, medical, or commercial
process such as life support, patient diagnosis, control of a manufacturing
process, or industrial testing of any kind.
What's Included
Go Direct Blood Pressure
l
Standard adult size adjustable cuff (27 cm to 39 cm)
l
Bulb pump (with release valve)
l
Micro USB Cable
l
Compatible Software
See
www.vernier.com/manuals/gdx-bp
Direct Blood Pressure.
Getting Started
Please see the following link for platform-specific connection information:
www.vernier.com/start/gdx-bp
Bluetooth Connection
1. Install Graphical Analysis 4 on
your computer, Chromebook™, or
mobile device. If using LabQuest 2,
make sure LabQuest App is up to
date. See www.vernier.com/ga4 for
Graphical Analysis 4 availability or
www.vernier.com/downloads to
update LabQuest App.
for a list of software compatible with Go
USB Connection
1. If using a computer or
Chromebook, install Graphical
Analysis 4. If using LabQuest 2,
make sure LabQuest App is up to
date. See www.vernier.com/ga4 for
Graphical Analysis 4 availability or
www.vernier.com/downloads to
update LabQuest App.
2. Charge your sensor for at least
2 hours before first use.
3. Turn on your sensor by pressing the
power button once. The LED will
blink red.
4. Launch Graphical Analysis 4 or
turn on LabQuest 2.
5. If using Graphical Analysis 4, click
or tap Sensor Data Collection. If
using LabQuest 2, choose Wireless
Device Setup > Go Direct from the
Sensors menu.
6. Select your Go Direct sensor from
the list of Discovered Wireless
Devices. Your sensor's ID is located
near the barcode on the sensor. The
LED will blink green when it is
successfully connected.
7. Click or tap Done. You are now
ready to collect data.
8. This is a multi-channel sensor. To
change the channel selections, see
www.vernier.com/start/gdx-bp
Charging the Sensor
Connect Go Direct Blood Pressure to the included USB Charging Cable and
any USB device for two hours.
You can also charge up to eight Go Direct Blood Pressure Sensors using our Go
Direct Charge Station, sold separately (order code: GDX-CRG). An LED on
each Go Direct Blood Pressure indicates charging status.
Charging
Fully charged
1
2. Connect the sensor to the USB
port.
3. Launch Graphical Analysis 4 or
turn on LabQuest 2. You are now
ready to collect data.
4. This is a multi-channel sensor. To
change the channel selections, see
www.vernier.com/start/gdx-bp
Orange LED next to the battery icon is solid
while the sensor is charging.
Green LED next to the battery icon is solid
when the sensor is fully charged.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Go Direct GDX-BP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vernier Go Direct GDX-BP

  • Page 1 Observing how the "fight or flight" response changes blood pressure successfully connected. 7. Click or tap Done. You are now Note: Vernier products are designed for educational use. Our products are not ready to collect data. designed nor are they recommended for any industrial, medical, or commercial 8.
  • Page 2: Powering The Sensor

    Important: The arm should rest at the level of the heart, and remain relaxed throughout data collection. A desk or table can be used to support www.vernier.com/start/gdx-bp the arm. The subject must remain still during data collection—no movement Connecting via Bluetooth of the arm or hand should occur during measurements.
  • Page 3: Calibrating The Sensor

    Note: If the cuff pressure does not reach 50 mmHg after 90 seconds, adjust the Adjusting the Pressure Release Valve The pressure release valve is set to release at a rate of 3.0 mmHg/s on an arm exhaust rate of the pressure release valve according to the directions listed under that is 32 cm in circumference.
  • Page 4: Specifications

    Although the battery is warranted for one year, the expected battery life calculated using a different percentage of maximum amplitude for the portion of should be several years. Replacement batteries are available from Vernier the envelope following MAP. For more information on this method see (order code: GDX-BAT-300).
  • Page 5: Warranty

    Vernier warrants this product to be free from defects in materials and Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :...
  • Page 6 The Bluetooth word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Vernier Software & Technology is under license. Other trademarks and trade names are those of their respective owners.

This manual is also suitable for:

Go direct blood pressureGdx-bp

Table of Contents