Summary of Contents for Valley-Dynamo Dynamo Fire Storm Hockey

  • Page 3: Warranty Length

    DEALERS AND DISTRIBUTORS – To obtain replacement and an RMA number, contact Valley-Dynamo referencing the Model number and Serial number of the unit and the nature of the problem. Valley-Dynamo will, at its discretion, send replacement parts and/or issue an RMA for...
  • Page 4 To avoid billing issues, request an RMA when the failed part is present or readily available. Credit will be issued only upon receipt and inspection of the RMA. Valley-Dynamo may send replacement parts or issue an account credit. NO REFUNDS. Valley- Dynamo reserves the right to cancel outstanding RMAs 30 days after issue.
  • Page 5: Exclusion Of Damages

    Valley-Dynamo’s sole obligation and liability under this warranty is limited to the repair or replacement of a defective product at our option. Valley-Dynamo shall not, in any event, be liable for any incidental or consequential damages resulting from interruption of service, loss of business or revenue, or for liability in tort relating to this product or resulting from its use or possession.
  • Page 6 USE OF NON-DYNAMO PARTS OR CIRCUIT MODIFICATIONS MAY CAUSE SERIOUS INJURY OR EQUIPMENT DAMAGE! USE ONLY GENUINE DYNAMO AUTHORIZED PARTS. • For safety and reliability, substitute parts and modifications are not recommended. • Substitute parts or modifications may void FCC type acceptance. •...
  • Page 7 Before proceeding, we recommend having these tools: • Socket Wrench with a 7/16” Socket • Phillips Screwdriver • Tape • Pliers – regular or needle-nose (preferably one of each) … this hardware included in your kit • ¼”-20 Kep Nuts (870052105) •...
  • Page 8 BE SAFE: We recommended that you have at least two people involved in the setup of this overhead. Seriously. BE PREPARED: Contact your Distributor immediately if any parts listed on the prior page are missing from your overhead or your bulbs arrived broken 1.
  • Page 9 Step 6: insert the nylon banding into the hole in the overhead unit, and direct it through the mounting tube. In step 7, you will use the banding to pull the wiring along this path. 6. The Fire Storm overhead’s unique design has narrower-diameter tubes than the standard overhead and it can be a challenge to feed the Overhead Wire Harness from the housing...
  • Page 10 8. On the Front Side wall of the table (containing the long door secured with two locks) remove the four screws and washers found at the center of the table. 9. Secure a Side Mounting Bracket using the screws and washers removed in the prior step. This part is tapered to follow the angled side on the table and should be installed with the LARGE holes UP, and the two SMALL holes facing DOWN.
  • Page 11 18. If the bulbs still do not illuminate, contact Valley-Dynamo Tech Support. 21. Reinstall the safety diffuser, secure the diffuser brackets using the ⅝” Phillips screws and #10 black washers.
  • Page 12 The most current and complete troubleshooting, technical and parts breakdown information can be found at any time at www.valleydynamoparts.com For additional assistance: Email anytime: techhelp@valley-dynamo.com During business hours (Central US Time): call 972.595.5300 and follow the prompts for Tech support We hope your proudly American-...