Do you have a question about the F Series and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Avid Technology F Series
Page 1
F, FM, & FE Series Water Softening System MODEL NUMBERS: Time Clock Mechanical Metered MODEL NUMBERS: FC Series FCM Series Electronic Metered F Series FM Series FCE Series FE Series High Efficiency High Efficiency High Efficiency FC-HE Series FCM-HE Series...
Table of Contents Pre-installation Instructions Page 2 Installation Page 4 Brine Tank Page 5 Bypass Valve Page 5 F Time Clock Timer Setting Page 7 FM Meter Setting Page 10 F & FM Adjust Time of Regeneration Page 11 FCE & FE Series Programming Page 12 Unit Model Specifications Page 15...
Pre-installation Instructions Description of the water softener system This water softener system includes a brine (salt) tank and a resin (media) tank with a backwashing control valve. Incoming water flows into the control valve and is directed down through the ion exchange softening resin.
Page 4
Pre-installation Instructions (cont.) Location Considerations The proper location to install the water softener system will ensure optimum performance and satisfactory water quality. The following factors should be considered in selecting the location of the equipment. 1. The water softener should be installed after the pressure tank on a private well system or after the water meter on municipal water.
Installation Instructions STEP 1: Carefully remove all components from packaging. DO NOT DISCARD PACKAGING until all water softener components and fittings have been located. STEP 2: Use clips and screws provided and attach bypass valve to the inlet/outlet of the control valve. See figure 2 below.
Installation Instructions (cont.) Connect one end of the provided 3/8” brine line to the control valve quick connect fitting. Insert STEP 7: the other end of the brine line through the hole in the brine tank and into the quick connect fitting on the safety brine valve.
Page 7
Installation Instructions (cont.) STEP 10: For all models except FE Series, plug the softener into an unswitched electrical outlet and slowly rotate the Manual Regeneration Knob (see Fig. 5, page 7 or Fig. 6, page 10) clockwise until two clicks are heard. This is the “BACKWASH” position. For the FE Series, plug the transformer into an un-switched electrical outlet and attach the power cord into the control valve.
FS Series Time Clock Setting Instructions Timer Operation FIGURE 5: Front of Time Clock Timer Assembly How to set Time of Day: 1. Press and hold the red button to disengage the 24 hour gear. 2. Turn the large 24 hour gear until the actual time of day is at the time of day arrow. 3.
Page 9
F Series Time Clock Setting Instructions (cont.) Adjusted Hardness -- Grains per Gallon People TABLE 1: Model Number F0844, FC0835 Adjusted Hardness -- Grains per Gallon People TABLE 2: Model Number F0948, FC1035, FI0948 Adjusted Hardness -- Grains per Gallon...
Page 10
F Series Time Clock Setting Instructions (cont.) Adjusted Hardness -- Grains per Gallon People TABLE 4: Model Number F1248, FI1248 Adjusted Hardness -- Grains per Gallon People TABLE 5: Model Number F1354...
FM Series Meter Setting Instructions FIGURE 6: Front of Meter Timer Assembly How to set Time of Day: 1. Press and hold the red button to disengage the 24 hour gear. 2. Turn the large 24 hour gear until the actual time of day is at the time of day arrow. 3.
F & FM Series Adjustable Regeneration Time Instructions FIGURE 7: Front of Timer Assembly (Time Clock Assembly Shown) How to Adjust Regeneration Time: 1. Disconnect the power source. 2. Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating the 24 hour dial until each screw appears in the cut out portion of the manual regeneration knob.
FCE & FE Series Programming Advance Button FIGURE 8: Front of Electronic Meter Timer Assembly SET BUTTON 1. Press and hold “Set Button” for 5 seconds to enter Programming Mode. 2. When valve is in Programming Mode, press “Set Button” to confirm setting and advance to next menu option.
Page 14
FEC & FE Series Programming Enter Programming Mode: Press and Hold the SET Button for 5 seconds. Use Up Button to set current hour Use Up Button to set current minute Use Up Button to set AM/PM Use Up Button to set ADJUSTED Hardness Exit Programming Mode...
Specifications UNIT MODEL NUMBER DESCRIPTION FC0835 FC1035 F0844 F0948 F1054 F1248 F1354 FCM0835 FCM1035 FM0844 FM0948 FM1054 FM1248 FM1354 MEDIA VOLUME, ft 0.75 0.75 CAPACITY, grains @Factory Salt - 9lb/ft 18,000 24,000 18,000 24,000 36,000 48,000 60,000 @Max. Salt - 15lb/ft 22,500 30,000 22,500...
Page 17
Specifications (cont.) UNIT MODEL NUMBER DESCRIPTION FI0948 FI1054 FI1248 FIM0948 FIM1054 FIM1248 MEDIA VOLUME, ft CAPACITY, grains @Factory Salt - 9lb/ft 24,000 36,000 48,000 @Max. Salt - 15lb/ft 30,000 45,000 60,000 SERVICE FLOW RATES, gpm Continuous (2 gpm/ ft Service (5 gpm/ ft Peak BACKWASH &...
FE (Electronic Metered) Control Valve Parts List Part REF # Part Number Description REF # Description Number Injector Body Plastic w/ o-ring 60040SS Stainless Steel Bypass, ¾” FPT 17776/10328 & brass elbow 60041SS Stainless Steel Bypass, 1” FPT 21257253 O-ring for PN: 17776/10328 Shown FES-MTR Meter Module for FES Model...
Troubleshooting PROBLEM CAUSE SOLUTION A. Ensure permanent electrical service A. Electrical service to unit has been to unit (switch, circuit breaker, plug, interrupted etc.) B. Faulty timer motor or micro switch B. Replace defective component 1. Softener fails to regenerate C.
Page 27
Troubleshooting (cont.) PROBLEM CAUSE SOLUTION A. Clean or replace injectors and A. Injectors or screen plugged screen B. Restricted drain flow control B. Clean drain line flow control 8. Salty water after regeneration C. Brine valve sticking C. Replace brine valve assembly D.
TEN YEAR LIMITED WARRANTY WARRANTY – First Sales, LLC. warrants this water conditioner against any defects that are due to faulty material or workmanship during the warranty period. This warranty does not include damage to the product resulting from accident, neglect, misuse, misapplication, alteration, installation or operation contrary to printed instructions, or damage caused by freezing, fire, flood, or Acts of God.