E: Motor to Motor Communications F: Access Control / FACP Inputs G: Alarm Condition Monitoring Outputs I: Remote Lane Control – Touchscreen Connection Options J: Earth Ground www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
/ card out for secure bi-directional traffic flow. The OBSG-HG-CV can also be set to operate in several other modes that are set by the Remote Lane Controller, or through your access control system. These modes include Free Exit, Free Entry, Exit Only, Enter Only, Disable Lane, and Close Lane.
4” below finished floor level for proper pedestal stability. Please contact us if you need advice on what type of hardware to use for your application. www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
Motor & Gearbox Receiver Sensors- There are 17 receiver sensors used to determine that the user is traveling through the lane correctly in the OBSG-HG-CV. The receiver sensors are always on the primary side of the lane. Alarm Speaker – One speaker is mounted above the PIO and produces the sound for each lane.
Interconnect Board Transmitter Sensors- There are 17 transmitter sensors that provide a signal for the receiver beams in the OBSG-HG-CV. The transmitter sensors will always be found on the secondary side of the lane. www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
16/2 24v power line from the power supply. The PIO will also receive communications to the remote lane controller (RLC) via either an Ethernet cable, or 18awg/4 conductor cable for serial communications. All pedestals must be grounded. www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
PIO. The Life Safety power supply provided with the units is capable of handling 1 – 2 OBSG-HG-CV speedgates. It should be located within 50 feet of the first pedestal. A separate 16-18 awg/2 conductor shall be “homerun” to each PIO. The power is then transferred to the adjacent pedestal’s SIO via an 18 awg/4 conductor...
J12 SIO to PIO data and power connector J1 Connect pins 1-4 from J12 on the PIO board to J1 on the SIO Board [10] www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
18/6 to PIO board Connector J17: Grant Enter = 1&2 Grant Exit = 3&4 Invalid Card = 5&6 FACP = 7&8 [11] www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
Alarm Lamp Output Ground (Common) 24vdc Ground Note: To activate any mode or feature (i.e. Free Exit) simply provide a jumper from that point to ground. [12] www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
RLC. The left column provides the functions that the turnstile is capable of operating remotely. [13] www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
Page 14
The single lane feature screen provides you with all the remote lane control features available on one screen, controlling one single lane at a time, with just a push of the button. Single Lane Screen [14] www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
Page 15
The Lane I/O Diagnostic screen provides Real time status of all lane inputs, outputs and sensor beams, as well as provides remote lane control, volume level adjustment, current firmware display and access to other interactive pages. Lane I/O Diagnostic Screen [15] www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...
Page 16
8) If the RLC is available, and after all skins are installed on the pedestals, verify that all of the sensors are still making contact in the Lane diagnostic screen. Receiver Transmitter [16] www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099...