EXDUL-584E
EDP-No: A-371940
EXDUL-584S
EDP-No: 371920
8 A/D inputs 16 bit (single ended) or
4 A/D outputs16 bit (differential)
8 D/A outputs16 bit
1 optocoupler isolated digital input
1 optocoupler isolated digital output
counter 32 bit
LCD display (EXDUL-584E only)
wasco
®
user's guide

Advertisement

Table of Contents
loading

Summary of Contents for Wasco EXDUL-584E

  • Page 1 EDP-No: 371920 8 A/D inputs 16 bit (single ended) or 4 A/D outputs16 bit (differential) 8 D/A outputs16 bit 1 optocoupler isolated digital input 1 optocoupler isolated digital output counter 32 bit LCD display (EXDUL-584E only) wasco ® user‘s guide...
  • Page 2 Important Information: This manual was made up for the modules EXDUL-584E and EXDUL-584S. EXDUL-584E additionally features an LCD display, all other functions are identical. For the EXDUL-584S all commands and functions concerning the LCD display are not applicable.
  • Page 3: Table Of Contents

    4.8 Configuration with Static IP Address (DHCP deactivated)........14 4.9 Configuration with Dynamic IP Address (DHCP enabled) ........16 4.10 LCD Display during the Booting Process (EXDUL-584E only) ......17 4.11 LCD Display during Operation (EXDUL-584E only) ..........18 5. Accessing the EXDUL-584 ............19 5.1 Accessing via the EXDUL Web Page ..............19...
  • Page 4 15.4 Wiring of the A/D Inputs single ended ............101 15.5 Wiring of the A/D Inputs differential ..............102 16. ASCII Table ..................103 17. Product Liability Act ..............106 18. CE Declaration of Conformity ...........108 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 5: Introduction

    150 mA. If necessary, the optocoupler input can be pro- grammed and used as a counter input. The programmable LCD display of the EXDUL-584E shows either digital I/O status information or program- mable user-specific data. An external power supply is required to supply the necessary operating voltage.
  • Page 6: Connection Terminals

    AIN04+ AIN07+ AIN06+ AOUT00+ AOUT01+ AOUT02+ AOUT03+ AOUT04+ AOUT05+ AOUT07+ AOUT06+ DAGND ADGND OUT00- OUT00+ IN00- IN00+ / Zähler0 GND_EXT Vcc_EXT Vcc_EXT: Connector for external voltage source GND_EXT: Ground connection EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 7: System Components

    Vcc +10V...+30V 16 Bit A/D Converter AIN00 - AIN07 FIFO Controller 16 Bit D/A Converter AOUT00 - AOUT07 Optocoupler Output OUT00 Counter Optocoupler Input IN00 Display Fig. 3.1 Block diagram EXDUL-584E EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 8: Block Diagram Exdul-584S

    Vcc +10V...+30V 16 Bit A/D Converter AIN00 - AIN07 FIFO Controller 16 Bit D/A Converter AOUT00 - AOUT07 Optocoupler Output OUT00 Counter Optocoupler Input IN00 Fig. 3.2 Block diagram EXDUL-584S EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 9: A/D Inputs

    Counting frequency: max. 5 kHz 3.8 LCD Display (only EXDUL-584E) Matrix display with 2 lines and 16 columns displaying 16 characters each line Programmable to display user specific data or I/O state EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 10: Deployment

    LED on the left side of the RJ45 jack is lit continuously. 4.2 Connecting the Operating Voltage The EXDUL-584E / EXDUL-584S requires a power supply of +10V ... +30V across terminal 23 (Vcc) and terminal 24 (GND). EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH...
  • Page 11: Integrated Webpage Of Exdul-584E / Exdul-584S

    User name: admin Password: 11111111 Please observe upper and lower case! If you don’t succeed in accessing with this access code, your system administrator changed the settings of the access code. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 12: Default Setting Of The Network Configuration

    Example: If subnet mask 255.255.0.0 is allocated to the IP address 192.168.1.83, then the device is located in the network 192.168.-.- as device -.-.1.83. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 13: How To Change The Network Configuration

    DHCP service is available, for neither the PC nor the EXDUL provides one. In this case, the last set static IP address can be used for addressing the EXDUL-584. The IP address 169.254.1.1 is applicable for factory-new EXDUL devices. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 14: Configuration With Static Ip Address (Dhcp Deactivated)

    EXDUL-584 configuration screen. To change the configuration, connect the EXDUL-584 to a LAN or PC as per description in chapter 4.7 (How to change the network configuration). EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 15 9 and the letters A through Z (leave out upper and lower case) and - (hyphen-minus). Some IP addresses are reserved or have special functions such as: 127.0.0.1 (local host). 192.168.1.0 (0 is the network address) with 255.255.255.0 (subnet mask). EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 16: Configuration With Dynamic Ip Address (Dhcp Enabled)

    EXDUL web page. Clicking the TCP/IP Config button opens the configuration screen and you can acitivate DHCP by setting the checkmark Enable DHCP as shown in the following figure: EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 17: Lcd Display During The Booting Process (Exdul-584E Only)

    ASCII digits 0 through 9 and the letters A through Z (leave out upper and lower case) and - (hyphen-minus). 4.10 LCD Display during the Booting Process (EXDUL-584E only) During booting-up the module, the display shows information data. Line 1 indicates the module name, line 2 displays the information that the module is being initialized.
  • Page 18: Lcd Display During Operation (Exdul-584E Only)

    LCD display. In order to avoid „screen-burn“ during operation, the display alternates from I/O status display or UserLCD display to information display with the current IP address for approx. 5 seconds every minute. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 19: Accessing The Exdul-584

    ExdulUtility_v2_xx or later) you can open the web page. If you don‘t succeed in opening the EXDUL-584 web page, please check the network connections or the entered hostname. For more details see chapter FAQ - trouble shooting. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 20: Accessing Via Tcp/Ip Sockets

    EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 21: How To Identify Hostname, Ip Address And Mac Address

    EXDUL-5xx, the program needs to be deallocated. The ExdulUtility_v2_xx search program (or a later version) is provided on the EXDUL software CD or available for download at www.messcomp. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 22: A/D Inputs 16 Bit

    As mentioned before, one byte for channel selection will be added to the command for measuring the voltage. Please see table 6.1 to choose the appropriate value for each channel when single ended measuring is used. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 23: Differential Operation

    AIN04 & AIN05 (-) + rally occurring interference + (-) voltages on both of the AIN06 & AIN07 (-) + signal lines and the analog ground. Figure 6.2-1 A/D converter differential measurement EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 24 An input voltage of +10V at AIN05 and an input voltage of -10V at AIN06 results in a difference of +20V, i.e. an input voltage range of +/- 20.4V must be chosen (see chapter 6.4) EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 25: Combination Of Single Ended And Differential Measurement

    Input Voltage Range Byte Value Voltage +/- 20.4V (differential measuring only max +/- 10.2V → GND) +/-10.2V +/- 5.1V +/-2,55V +/-1.27V +/- 0.63V Table 6.4 A/D converter input voltage ranges EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 26 = +20V diff AIN01 -10V the difference between two inputs may be +20.4V or -20.4V (e.g. AIN00 = +10.2V and -10.2V AIN01 = -10.2V, V = 20.4V) diff Fig. 6.4.3 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 27: Modes Of Measurement

    Duration = Number of channels*32*10µs After completion, the values are calibrated and returned to the user in µV. Example: Start 1st channel, 32 Measurements 2nd channel, 32 Measurements 3rd channel, 32 Measurements Fig. 6.5 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 28 It is recommended to operate this measurement mode with a sampling rate of up to 20kS/s only. Additionally, you must not write to any EXDUL information register during this period. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 29: Adjustment Of The A/D Inputs

    A/D component can be adapted to the environ- ment by subsequent adjustment. The required software is provided on the enclosed CD or on the Internet. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 30: D/A Outputs 16 Bit

    If there should be larger temperature devi- ations in the end application, the D/A component can be adapted to the environment by subsequent adjustment. The required software is provided on the CD or on the Internet. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 31: Optocoupler Input

    The isolation voltage between the ground of the computer ad the and input is 500 volts. 8.1 Pin assignment of the input optocoupler 16,14,12,10 15,13,11,9 1,3,5,7 2,4,6,8 Fig. 8.1 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 32: Input Circuitry

    ® 8.2 Input Circuitry Optocoupler IN00+ Protection Diode IN00- Fig 8.2 8.3 Input Current - 1,1V ≈ 3200Ω EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 33: Optically Isolated Output

    500 volts. 9.1 Pin assignment of the output optocoupler 9.2 Optocoupler specifications Voltage collector-emitter: max. 50V Voltage emitter-collector: 0,1V Current collector-emitter: 150 mA 9.3 Output circuitry Optocoupler OUT..+ Schutzdiode OUT..- EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 34: Information, Lcd And User Register

    The register Serial Number is a read-only register. The serial number in the table above serves as a format example. The line S/N shows each Hex value and the corresponding ASCII character as for the serial number 1044026. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 35: Memory Areas Usera, Userb, Userlcd1M* Und Userlcd2M

    The data in the registers UserLCD-line1 and UserLCD-line2 is not retained when switching off. You can adjust the LCD display contrast in register LCD contrast. This adjustment is retained when switching off. *: EXDUL-584E only, no application for EXDUL-584S EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 36: Installing The Driver

    TCP/IP libraries are required, which are available in many high-level languages such as C, C++, C#, Visual Basic or Java. Access examples in several programming languages are provided on the enclosed CD or on our website www.mewsscomp.com. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 37: Programming

    EXDUL modules as uniform as possible. This facilitates the user, if necessary, to switch from e.g. a USB EXDUL module to an Ethernet EXDUL module (for example EXDUL-384 -> EXDUL-584) without exten- sive programming efforts. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 38 Parameter: type: Info-Typ (see manual) Returned values: Returns the register "type" as a string Description: Reads the Module Information Register Info Area Info Byte UserA UserB Hardware Identifier Serial Number EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 39 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Write the LCD-Modes: void SetLCDMode(byte mode) Parameter: mode: LCD mode Description: sets the LCD mode LCD Mode LCD Mode Byte IO Mode User Mode EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 40 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH...
  • Page 41 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH...
  • Page 42 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH...
  • Page 43 +/- 0.63V AIN05 AIN06 AIN07 Differential measuring AIN00+ / AIN01- AIN00- / AIN01+ AIN02+ / AIN03- AIN02- / AIN03+ AIN04+ / AIN05- AIN04- / AIN05+ AIN06+ / AIN07- AIN06- / AIN07+ EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 44 +/- 0.63V AIN05 AIN06 AIN07 Differential measuring AIN00+ / AIN01- AIN00- / AIN01+ AIN02+ / AIN03- AIN02- / AIN03+ AIN04+ / AIN05- AIN04- / AIN05+ AIN06+ / AIN07- AIN06- / AIN07+ EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 45 +/- 0.63V AIN05 AIN06 AIN07 Differential measuring AIN00+ / AIN01- AIN00- / AIN01+ AIN02+ / AIN03- AIN02- / AIN03+ AIN04+ / AIN05- AIN04- / AIN05+ AIN06+ / AIN07- AIN06- / AIN07+ EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 46 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH...
  • Page 47 +/- 0.63V AIN05 AIN06 AIN07 Differential measuring AIN00+ / AIN01- AIN00- / AIN01+ AIN02+ / AIN03- AIN02- / AIN03+ AIN04+ / AIN05- AIN04- / AIN05+ AIN06+ / AIN07- AIN06- / AIN07+ EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 48 +/- 0.63V AIN05 AIN06 AIN07 Differential measuring AIN00+ / AIN01- AIN00- / AIN01+ AIN02+ / AIN03- AIN02- / AIN03+ AIN04+ / AIN05- AIN04- / AIN05+ AIN06+ / AIN07- AIN06- / AIN07+ EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 49 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Factory Reset: void DefaultReset() Description: Resets the module to the factory settings. After this command the module has to be shut down and restarted again. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 50: Programming With Tcp-Libraries

    The last result or confirmation string has to be read before transmitting a new string. Module 4 + n Byte Command1 4 + m Byte Reply1 4 + x Byte Command2 4 + y Byte Reply2 Fig. 12.4 Communication model EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 51 The number of the 4 byte blocks varies from command to command and depends in part on the volume of data to be transmitted. More detailed information can be found in the individual command descriptions. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 52 8 more bytes have been appended holding the password. Additionally, the length byte has to be increased by 2 (+8 bytes). The response does not contain a password and corresponds to the usual response array without a password. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 53 0A 00 0A Start AD continuous sampling 0A 00 0B Stop AD continuous sampling Configurate DA input voltage range 0A 80 00 0A 80 01 Output DA voltage 09 00 00 Counter0 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 54 Data 11th character [blank] asci Data 12th character [blank] asci Data 13th character [blank] asci Data 14th character [blank] asci Data 15th character [blank] asci Data 16th character [blank] asci EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 55 Data 11th character [blank] asci Data 12th character [blank] asci Data 13th character [blank] asci Data 14th character [blank] asci Data 15th character [blank] asci Data 16th character [blank] asci EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 56 Data 11th character [blank] asci Data 12th character [blank] asci Data 13th character [blank] asci Data 14th character [blank] asci Data 15th character [blank] asci Data 16th character [blank] asci EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 57 Data 3rd character 4 Read function info area Data 4th character 4 Data 5th character 0 Data 6th character 2 Data 7th character 6 reserved reserved reserved reserved reserved reserved reserved reserved reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 58 Data 11th character [blank] asci Data 12th character [blank] asci Data 13th character [blank] asci Data 14th character [blank] asci Data 15th character [blank] asci Data 16th character [blank] asci EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 59 UserLCD1m or UserLCD2m at module start. All of the registers are readable as whole 16-byte blocks only. LCD Command LCD Command Byte UserLCD1 & UserLCD2 UserLCD1m & UserLCD2m EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 60 Data Line2 12th character [blank] asci Data Line2 13th character [blank] asci Data Line2 14th character [blank] asci Data Line2 15th character [blank] asci Data Line2 16th character [blank] asci EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 61 Command code 3rd Byte Length byte → 8 Byte Length byte → 0 Byte LCD Command LCD mode reserved reserved Write function 00 (IO Mode) LCD mode 01 (User Mode) reserved reserved reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 62 Command code 3rd Byte Length byte → 4 Byte Length byte → 4 Byte 00 (IO-Mode) LCD command LCD mode LCD mode 01 (User-Mode) reserved reserved reserved reserved read function reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 63 Length byte → 4 Byte Length byte → 4 Byte LCD command LCD contrast Contrast value (Lowbyte - 00...FF) reserved Contrast value (Highbyte - 00...0F) reserved reserved read function reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 64 Hostname 16th character [blank] asci 4th Byte IP address decimal value 63 3rd Byte IP address decimal value 0 2nd Byte IP address decimal value168 1st Byte IP address decimal value 192 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 65 Secondary DNS 3rd Byte decimal value 151 Secondary DNS 2nd Byte decimal value 237 Secondary DNS 1st Byte decimal value 217 DCHP client configuration 00 (DHCP disable) 01 (DHCP enable) reserved reserved reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 66 1st Byte IP address decimal value 192 4th Byte Subnetmask decimal value 0 3rd Byte Subnetmask decimal value 255 2nd Byte Subnetmask decimal value 255 1st Byte Subnetmask decimal value 255 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 67 01 (DHCP enable) Reserved Reserved Reserved Reserved Reserved MAC address 6th character MAC address 5th character MAC address 4th character MAC address 3rd character MAC address 2nd character MAC address 1st character EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 68 Command code 1st Byte Command code 2nd Byte Command code 3rd Byte Length byte → 20 Byte 00 (Password deactivated) Security Byte 01 (Password activated) reserved reserved Write function Security configuration EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 69 Command code 1st Byte Command code 2nd Byte Command code 3rd Byte Length byte → 20 Byte 00 (Password deactivated) Security Byte 01 (Password activated) reserved reserved Read function Security configuration EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 70 Password 3rd character D asci Password 4th character U asci Password 5th character L asci Password 6th character 5 asci Password 7th character 8 asci Password 8th character 4 asci EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 71 Transmit Receive Representing Command code 1st Byte Command code 2nd Byte Command code 3rd Byte 01 (→ 4Byte) Length byte r/w Byte 00 (disabled) optocoupler state 01 (enabled) reserved reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 72 Furthermore, you can read in and reset the overflow flag. Code Counter command start counter stop counter reset counter read counter value reserved read overflow flag reset overflow flag EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 73 Counter value Byte2 Counter value Byte3 Counter reading = counter status Byte3 * 0x1000000 + counter status Byte2 * 0x10000 + counter status Byte1 * 0x100 + counter status Byte0 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 74 Command code 3rd Byte 01 (→ 4Byte) Length byte Length byte Counter command code Counter command code reset the overflow flag reset the overflow flag reserved reserved reserved reserved reserved reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 75 Measured value Byte0 Range byte Measured value Byte1 Measured value Byte2 Measured value Byte3 Voltage = (integer) (Byte3 * 0x1000000 + Byte2 * 0x10000 + Byte1 * 0x100 + Byte0) [µV] EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 76 Range byte Measured value Byte1 reserved Measured value Byte2 reserved Measured value Byte3 Voltage = (integer) (Byte3 * 0x1000000 + Byte2 * 0x10000 + Byte1 * 0x100 + Byte0) [µV] EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 77 3 + n*4 Channel byte 4 + n*4 +1 Measured value Byte1 4 + n*4 Range byte 4 + n*4 +2 Measured value Byte2 4 + n*4 +3 Measured value Byte3 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 78 * 0x10000 + Byte1 * 0x100 + Byte0 ) [µV] Measured value AIN04 = (integer) (Byte3 * 0x1000000 + Byte2 * 0x10000 + Byte1 * 0x100 + Byte0 ) [µV] EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 79 Command code 2nd Byte Command code 3rd Byte Command code 3rd Byte Length byte → 4 Bytes Length byte Overflow flag 00 FIFO not overflown 01 FIFO overflown reserved reserved reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 80 Measured value Byte1 Measured value Byte2 Measured value Byte3 Measured value Byte0 n*4 + 1 Measured value Byte1 n*4 + 2 Measured value Byte2 n*4 + 3 Measured value Byte3 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 81 Length byte → 8 bytes Length byte Measured value Byte0 Measured value Byte1 Measured value Byte2 Measured value Byte3 Measured value Byte0 Measured value Byte1 Measured value Byte2 Measured value Byte3 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 82 (command + length byte) length byte > 0 There are 4 Bytes of length byte in the receiving buffer FIFO is empty read 4 Bytes of length byte receiving routine completed EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 83 +/- 0.63V AIN05 AIN06 AIN07 Differential measuring AIN00+ / AIN01- AIN00- / AIN01+ AIN02+ / AIN03- AIN02- / AIN03+ AIN04+ / AIN05- AIN04- / AIN05+ AIN06+ / AIN07- AIN06- / AIN07+ EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 84 + 10 Channel byte n*4 + 11 Range byte Sampling rate = Byte2 * 65536 + Byte1 * 256 + Byte0 Number of readings = Byte1 * 256 + Byte0 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 85 +/- 0.63V AIN05 AIN06 AIN07 Differential measuring AIN00+ / AIN01- AIN00- / AIN01+ AIN02+ / AIN03- AIN02- / AIN03+ AIN04+ / AIN05- AIN04- / AIN05+ AIN06+ / AIN07- AIN06- / AIN07+ EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 86 Receive Representing Command code 1st Byte Command code 1st Byte Command code 2nd Byte Command code 2nd Byte Command code 3rd Byte Command code 3rd Byte Length byte Length byte EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 87 Command code 1st Byte Command code 2nd Byte Command code 2nd Byte Command code 3rd Byte Command code 3rd Byte Length byte Length byte Channel byte (0 ... 7) Range byte reserved reserved EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 88 Channel byte (0 ... 7) reserved reserved reserved voltage Byte0 voltage Byte1 voltage Byte2 voltage Byte3 voltage = (integer) (Byte3 * 0x1000000 + Byte2 * 0x10000 + Byte1 * 0x100 + Byte0) [µV] EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 89: Access To The Module Via Labview And Exdul.dll

    Due to the EXDUL.dll., the module can be integrated into a LABView project without much effort. Along with the .NET Framework additionally LABView and the EXDUL.dll file is required on the computer. We refer to the EXDUL-LABView Tutorial for more detailed information. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 90: Faq - Trouble Shooting

    EXDUL-584 and computer (a crossover cable might be required). For network operation, check network cables between EXDUL-584 and the wall-mounted network socket, the active Ethernet switch or the Ethernet hub. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 91 The Ethernet adapter has to be activated in the BIOS of your PC. Check the Windows Device Manager whether it is listed under Network Adapter. The entry must not be marked with an exclamation mark! EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 92 (network ID: 192.168.1., device ID 199). To access the EXDUL-584 the used PC has to be set to subnet mask 255.255.255.0 and to static IP address ranging from 192.168.1.1 up to 192.168.1.244 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 93 For this, switch to the MS-DOS prompt (see „How to switch to MS-DOS prompt“), type ipconfig and press enter to confirm. The response should look similar to the following figure: EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 94 -> select required LAN connection (double-click or right mouse button) -> properties -> highlight Internet Protocol (TCP/IP) -> properties Please note: you have to own administrator privileges for changing TCP/ IP settings! EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 95 EXDUL-5xx directly connected to a PC as well as for a network connected via hub or switch with several modules. In case the firewall prevents the searching program from communicating with the EXDUL-5xx a release is required. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 96: Specifications

    = 10..30 Volt low = 0..3 Volt Optocoupler outputs 1 channel, galvanically isolated High capacity optocoupler Reverse polarity protection Output current: max. 150 mA Switching voltage: max. 50 V EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 97 Insulating plastic housing with integrated snap-in technology for DIN EN top hat rail mounting. Suitable for control and engineering technology mounted to control and distribution boxes, surface mounting or mobile use on a desk. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 98: Circuitry Examples

    15.1 Wiring of the Optocoupler Input Circuit breaker open = „0“ EXDUL-584 Circuit breaker closed = „1“ Circuit breaker IN00+ + 24V (V IN00- (GND Principle circuit diagram Figure 15.1 Optocoupler input wiring EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 99: Wiring Of The Optocoupler Output

    ® 15.2 Wiring of the Optocoupler Output EXDUL-584 Electrical loads OUT00+ + 24V (V e.g. lamp, relays,actuator OUT00- (GND Principle circuit diagram Figure 15.2 Optocoupler output wiring EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 100: Wiring Of The D/A Outputs

    15.3 Wiring of the D/A Outputs Internal External AOUT00 max. 5mA DAC1 AOUT01 max. 5mA Electr. Load DAC2 Electr. Load AOUT07 ADGND DAC8 Figure 15.3 Wiring of the D/A outputs EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 101: Wiring Of The A/D Inputs Single Ended

    ® 15.4 Wiring of the A/D Inputs single ended Internal External AIN00 AIN01 Multiplexer Range Selection unwired Channels AIN07 ADGND Figure 15.4 Wiring of the A/D inputs (single ended) EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 102: Wiring Of The A/D Inputs Differential

    ® 15.5 Wiring of the A/D Inputs differential Internal External AIN00 AIN02 AIN06 Multiplexer Range Selection AIN01 AIN03 AIN07 unwired inputs ADGND Figure 15.5 Wiring of the A/D inputs (differential) EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 103: Ascii Table

    00011011 01000011 00011100 01000100 00011101 01000101 00011110 01000110 00011111 01000111 00100000 [space] 01001000 00100001 01001001 „ 00100010 01001010 00100011 01001011 00100100 01001100 00100101 01001101 00100110 & 01001110 ‚ 00100111 01001111 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 104 01101101 10011001 01101110 10011010 01101111 10011011 01110000 10011100 01110001 10011101 01110010 10011110 01110011 10011111 01110100 10100000 01110101 10100001 01110110 10100010 01110111 10100011 01111000 10100100 01111001 10100101 01111010 10100110 01111011 10100111 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 105 11000101 11110001 11000110 11110010 11000111 11110011 11001000 11110100 11001001 11110101 11001010 11110110 11001011 11110111 11001100 11111000 11001101 11111001 11001110 11111010 11001111 11111011 11010000 11111100 11010001 11111101 11010010 11111110 11010011 11111111 EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 106: Product Liability Act

    Particular attention must be drawn to the following instructions: VDE100; VDE0550/0551; VDE0700; VDE0711; VDE0860. You can obtain the instructions from: vde-Verlag GmbH Bismarckstr. 33 10625 Berlin EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 107 Apart from that, compliance with consruction regulations and safety in- structions of all kinds (VDE, TÜV, professional associations, industrial injuries corporation, etc.) is subject to the user/customer. EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 108: Ce Declaration Of Conformity

    EN 50082-1 EN 60555-2 EN 60555-3 The following manufacturer is responsible for this declaration: Messcomp Datentechnik GmbH Neudecker Str. 11 83512 Wasserburg issued by Dipl.Ing.(FH) Hans Schnellhammer Wasserburg, 31.01.2018 ________________________________ EXDUL-584E / EXDUL-584S © 2018 by Messcomp Datentechnik GmbH EV06...
  • Page 109 ® Reference system for intended use The multi functional modules EXDUL-584E and EXDUL-584S are not stand-alone devices. The CE-conformity only can be assessed when using additional computer components simultaneously. Thus the CE conformity only can be confirmed when using the following reference...

This manual is also suitable for:

Exdul-584sA-371940371920

Table of Contents