Download Print this page

KINTERA KSP1 Installation & Operation Manual

Gas stock pot

Advertisement

Available languages

Available languages

Quick Links

INSTALLATOIN &OPERATIONMANUAL
GAS STOCK POT RANGE
Kintera Equipment, LLC
PO Box 1186
Mansfield MA 02048
FOR WARRANTY SERVICE CALL 866-909-2855
Register your product warranty online at: www.entree.biz
This manual contains important information regarding your KINTERA unit. Please
read the manual thoroughly prior to equipment set-up, and operation maintenance.
Failure to comply with regular maintenance guidelines out-lined in the manual may
void the warranty. Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death. Read this manual
thoroughly before installing or servicing this equipment.
MUST READ!
1
Gas Stock Pot Range Owner's Manual Ver 20180822
FOR WARRANTY SERVICE CALL 866-909-2855

Advertisement

loading
Need help?

Need help?

Do you have a question about the KSP1 and is the answer not in the manual?

Questions and answers

Summary of Contents for KINTERA KSP1

  • Page 1 FOR WARRANTY SERVICE CALL 866-909-2855 Register your product warranty online at: www.entree.biz This manual contains important information regarding your KINTERA unit. Please read the manual thoroughly prior to equipment set-up, and operation maintenance. Failure to comply with regular maintenance guidelines out-lined in the manual may void the warranty.
  • Page 2 Specifications of Stock Pot Range External Dimensions Total BTU’s Crated Weight(lbs) Model Burners Natural KSP1 1(3rings,2valves) 80,000 80,000 KSP2 2(3rings,2valves) 160,000 160,000 Shipped setup for Natural Gas and includes a kit for conversion to Propane Gas Orifice Size for Natural Gas is 3.15 mm, Orifice Size for Propane is 1.95 mm Thank you for purchasing this equipment.
  • Page 3 SAFETY PRECAUTOINS FOR YOUR SAFETY Do not store or use gasoline or other flammable To ensure safe operation read the following vapors or liquids in the vicinity of this or any other statements and understand their meaning. Please appliance read carefully. Improper installation, adjustment, alteration, service Warning is used to indicate the presence of a hazard that severe...
  • Page 4 The installation of this appliance must conform with Gas piping: Gas piping shall be of such size and so local codes, or in the absence of local codes, with the installed as to provide a supply of gas sufficient to meet National Fuel Gas Code, ANSIZ223.1/NFPA 54, or the the full gas input of the appliance.
  • Page 5 Natural Gas Orifice 3.15 mm Pilot flame regulation: The pilot flame on the appliance LP(propane)Gas Orifice 1.95 mm has been factory adjusted. When adjustment is necessary, adjust the pilot flames as small as possible, but high enough to light the burner immediately when burner valve is turned to the “High”...
  • Page 6: Fire Hazard

    WARNING FIRE HAZARD If you smell gas follow the instructions provided by the gas supplier. Do not touch any electrical switch; do not try to light the burner; do not use a telephone within close proximity. Before initial use, turn the gas control knob to the maximum setting, and allow equipment to burn-in for 15 minutes.
  • Page 7 KINTERA shall not be liable, under any legal theory, for loss of use, revenue or profit, or for substitute use or performance, or for incidental, indirect, or special or consequential damages, or for any other loss of cost of similar type.
  • Page 8 MAINTAIN PRODUCT AS SET FORTH IN THE OWNER’S MANUAL PROVIDED WITH THE UNIT. RELOCATION OF EQUIPMENT FOR REPAIR: KINTERA is not responsible for the cost to move the unit for any reason from its position of operation on the customer's premises to make a warranty repair.
  • Page 9 When service is needed, contact a KINTERA Authorized Service Agency, or your dealer. To avoid confusion, always refer to the Model Number, Serial Number, and Type of your unit.
  • Page 10 Gas Stock Pot Range Owner’s Manual Ver 20180813 FOR WARRANTY SERVICE CALL 866-909-2855...
  • Page 11 FOR WARRANTY SERVICE CALL 866-909-2855 Register your product warranty online at: www.entree.biz Ce manuel renferme de l’information importante touchant votre appareil KINTERA. Prière de lire ce manuel attentivement avant de l’installer, de l’opérer et de l’entretenir. Le défaut de se conformer aux consignes d’entretien décrites dans ce manuel pourrait annuler la garantie.
  • Page 12 Caractéristiques techniques des cuisinières à marmites Dimensions externes BTU totaux Poids embarqué Modèle Brûleurs en lb (kg) Naturel KSP1 1(3 anneaux,2 robinets) 80000 80000 145 (66) KSP2 2(3anneaux,2 robinets) 160000 160000 292 (132) ** Livraison en mode de fonctionnement au gaz naturel avec trousse de conversion au gaz propane.
  • Page 13 MESURES DE SÉCURITÉ Pour un fonctionnement sécuritaire, lisez les Toute installation, réglage, modification, entretien ou énoncés suivants et comprenez-en le sens. Lisez réparation fait incorrectement peut entraîner des attentivement s’il vous plaît. dommages matériaux, des blessures ou la mort. Lire les consignes d’installation, d’opération, et d’entretien attentivement avant d’installer ou d’entretenir cet Un avertissement sert à...
  • Page 14 L’installation de cet appareil doit être conforme avec les codes locaux, ou Tuyauterie de gaz :La tuyauterie de gaz devra être d’une taille suffisante pour en leur absence, avec le Code national des gaz de combustion, norme répondre à la demande de gaz requise par l’appareil et installée en conséquence. ANSIZ223.1/NFPA 54, ou, le cas échéant, avec le Code d’installation au gaz Si on doit raccorder l’appareil à...
  • Page 15 une entreprise de service locale pour effectuer un entretien ou une réparation. Installation & mode d’emploi, cuisinières à marmites, version 20180822 POUR APPELS SOUS GARANTIE, FAIRE LE (866) 909-2855...
  • Page 16: Fonctions Et Commandes

    FONCTIONS ET COMMANDES AVERTISSEMENT DANGER D’INCENDIE Si vous sentez une odeur de gaz, suivez les instructions données par votre fournisseur de gaz. Ne touchez à aucun commutateur électrique; ne tentez pas d’allumer le brûleur; ne vous servez pas d’un téléphone à proximité immédiate. Avant la première utilisation, tournez le bouton de contrôle du gaz au réglage Figure 1.
  • Page 17 23. Cette garantie constitue l’unique recours contre KINTERA, relié à tout ce qui est KINTERA, que ce soit par contrat ou en délit civil ou selon toute autre théorie légale, et qu’il découle de garanties, représentations, instructions, installations, ou de défauts de toutes causes.
  • Page 18 INONDATION, FORCE MAJEURE. KINTERA n’assume pas de responsabilité pour la réparation ou le remplacement de toute pièce, si KINTERAdétermine qu’elle a été soumise, après la date de fabrication, à desaltérations, de la négligence, de l’abus, un mauvais usage, un accident,et a subi des dommages pendant le transport ou l’installation, lors d’un incendie, d’une inondation, ou dans un cas de force majeure.
  • Page 19 FOR WARRANTY SERVICE CALL 866-909-2855 Register your product warranty online at: www.entree.biz Un produit qui porte le nom de KINTERA comprend ce qu’il y a de mieux en matière de durabilité et de faible coût d’entretien. Cependant, nous reconnaissons tous que le remplacement de certaines pièces et à...

This manual is also suitable for:

Ksp2