SapphireScientific Dri-Eaz HVE3000 Owner's Manual

SapphireScientific Dri-Eaz HVE3000 Owner's Manual

Flood pumper and inline booster

Advertisement

Quick Links

HVE3000 Flood Pumper and Inline Booster
Phone: +1 360-757-7776 Fax: +1 360-757-7950
The high-efficiency HVE3000 can be used both as a flood pumper to quickly remove excess
liquid water for flood remediation and as an inline truckmount booster to extend the
effective vacuum hose length for carpet extraction and cleaning.
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
SAFETY INSTRUCTIONS
WARNING
WARNING! Do not alter or modify your HVE3000 in
any way. Use only replacement parts authorized by
Legend Brands, Inc. Modifications or use of
unapproved parts could create a hazard and will
void your warranty. Contact your authorized Dri-Eaz
or Sapphire distributor for assistance.
WARNING! Electric shock hazard, vacuum impeller,
and hot surface hazards.
Do not leave appliance when plugged in. Unplug from
outlet when not in use and before servicing.
To protect your valuable equipment and prevent voiding the warranty, read and follow these instructions:
Install the HEPA filter when using the unit on Category 3 restoration jobs.
Remove and discard filter at the end of the all Category 3 restoration jobs. Hearing protection is recommended.
Use defoaming chemicals whenever foam is present in waste tank.
Replace the HEPA filter if it gets wet during operation.
If foam/water is pulled through the vacuum blower, remove hose/wand and run blower unit for 5 minutes to dry
out the system prior to storing.
Maintenance
Replace vacuum blower brushes after 800 hours of operation.
07-01955E F479-230V/78-006 AU
Owner's Manual
LEGEND BRANDS, INC.
15180 Josh Wilson Road, Burlington, WA 98233, USA
Patents:
http://www.LBpatents.com
PROTECT YOUR EQUIPMENT
Failure to follow these instructions can damage the vacuum system.
F479-230V AU
international.legendbrands.net
Do not allow to be used as a toy. Close attention is
necessary when used by or near children.
Do not pull or carry by cord, use a cord as a handle,
close a door on a cord, or pull a cord around sharp
edges or corners. Do not run appliance over cord. Keep
cord away from heated surfaces.
Do not unplug by pulling on cord. To unplug, grasp the
plug, not the cord.
Do not handle plug or appliance with wet hands.
Do not put any object into openings. Do not use with any
opening blocked; keep free of dust, lint, hair, and
anything that may reduce air flow.
Turn off all controls before unplugging.
Use extra care when cleaning on stairs.
Do not use to pick up flammable or combustible liquids,
such as gasoline, or use in areas where they may be
present.
Connect to properly grounded outlet only. See
Grounding Instructions.
To reduce the risk of fire and electric shock due to
internal component damage, use only VersaClean
cleaning fluids intended for use with this appliance.
Use indoors only.
1
Legend Brands, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dri-Eaz HVE3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for SapphireScientific Dri-Eaz HVE3000

  • Page 1 Owner’s Manual HVE3000 Flood Pumper and Inline Booster F479-230V AU LEGEND BRANDS, INC. 15180 Josh Wilson Road, Burlington, WA 98233, USA Phone: +1 360-757-7776 Fax: +1 360-757-7950 international.legendbrands.net The high-efficiency HVE3000 can be used both as a flood pumper to quickly remove excess liquid water for flood remediation and as an inline truckmount booster to extend the effective vacuum hose length for carpet extraction and cleaning.
  • Page 2: Before You Begin

    Store indoors only, and protect from freezing. proper electric circuit. Make sure that the appliance is connected to an outlet having the same configuration as Do not expose to rain or snow. the plug. No adaptor should be used with this appliance. BEFORE YOU BEGIN If the appliance must be reconnected for use on a different type of electric circuit, the connection should be...
  • Page 3: Parts Identification

    PARTS IDENTIFICATION FIG. A: FRONT FIG. B: REAR Filter basket cover. Handle Remove by lifting Vacuum outlet. Connect clamps. to truckmount for use as Vacuum inlet (from booster. Keep capped extraction tool). when not in use. Control panel. Details Cover assembly in Fig.
  • Page 4: Extraction Mode Setup

    EXTRACTION MODE SETUP FIG. D Remove water quickly and effectively from flooded structures. Filter lid 1) Connect vacuum hose to vacuum inlet. 2) Connect power cord to power supply Filter lid seal NOTICE: The power cord of the HVE3000 should be plugged into a ground-protected 230 volt outlet.
  • Page 5: Maintenance

    with force. Water may contain chemicals or 1. Release four cover assembly latches and lift off cover contaminants that can be a health hazard upon contact. assembly (see Fig. D). With gravity drain hose directed into a suitable drain, remove any accumulated debris and wash recovery tank interior with an all-purpose Airflow shut-off detergent.
  • Page 6 Remove the cover assembly and inspect the recovery tank for any remaining water. If necessary, wipe out the tank with a towel. Loosen hose clamp on float valve assembly and slip off assembly. Loosen cord clamp on inside wall of tank with the 15/16 in.
  • Page 7 If you are servicing the float ball assembly, use a Philips screwdriver to remove the float ball housing retaining screw and remove the float ball housing. Rinse all components clean and ensure float ball moves freely inside housing. Reinstall float ball housing. Inspect float assembly.
  • Page 8 Loosen upper pump outlet hose clamp and pull the hose off the outlet. Fold up the pump handle and lift out the pump for inspection. Rest the pump on a table or other stable surface placed next to the unit. There is no need to disconnect the wire harness.
  • Page 9 Wipe out tank with a clean rag. Reassembly Lower pump back into bottom of tank and fold handle down. Ensure that the pump feet are fully seated. Push pump outlet hose back on and retighten hose clamp. Replace pump retention bracket. Push excess power cord back through cord grip and retighten cord grip.

Table of Contents