Included Items
When you open the box, you will find the following items. Check the box for each of the following items before assembling the Ready-
Link-Rack. The quantity of each item differs depending on the number of water heaters or boilers you want to install.
If any of these items are missing or damaged, please contact our customer service center at 1-800-519-8794.
Installation Guide Post bar 64.4 in
Fixed bar 17.7 in
Base frame 32 in
1 EA
* Single kit: 2 EA
* Single kit: 2 EA
* Single kit: 2 EA
** Extension kit: 1 EA
** Extension kit: 2 EA
** Extension kit: 1 EA
Reinforcement
Tapping screw 5x12
Tapping screw 5x12
M10 bolt
plate
(washers set, stainless steel)†
(stainless steel)†
(3 in, stainless steel)
* Single kit: 4 EA
* Single kit: 20 EA
* Single kit: 2 EA
* Single kit: 22 EA
** Extension kit: 2 EA
** Extension kit: 12 EA
** Extension kit: 2 EA
** Extension kit: 14 EA
† Spare tapping screws are provided in the product package for your convenience.
† All 14 M10 bolts (3 in) of the extension kit will be used for the NFC series when installed in combination with the NPE, NCB, and NFB series.
Other configurations will have one bolt left over.
† The 5x12 tapping screws without washers are only used for installing the NPN series.
* A single kit can be used to mount up to 2 water heater or boiler units. When mounting 2 units, the back-to-back configuration can be used.
** An extension kit is used to add more water heater or boiler units to the frame.
*** These kits can be installed both indoors and outdoors.
Note
Although the floor mounting hardware is not included with this kit, you must fix the Ready-Link-Rack securely to the floor to
complete installation. Use appropriate anchor bolts (3/8 in) to fix the frame to the ground.
Ready-Link-Rack
Installation Guide(V3)
Model
NPE-A, NPE-S Series
NCB-E Series
NHB Series
NFB-175, 200
NFC-175, 200
NPN Series
WARNING
If the information in these instructions is not followed
exactly, a fire or explosion may occur and potentially cause
property damage, personal injury, or death.
Keep this manual for future reference.
Fixed bracket
Fixed bracket
Fixed bracket
(under)
(middle)
(upper)
* Single kit: 4 EA
*Single kit: 4 EA
*Single kit: 2 EA
** Extension kit: 2 EA
**Extension kit: 4 EA
**Extension kit: 2 EA
M10 bolt
5/32 in or
(2.8 in, stainless steel)
4 mm Allen wrench
* Single kit: 3 EA
1 EA
** Extension kit: 3 EA
Installation Considerations
Refer to the following information to find an adequate
installation location for the frame and prepare the appropriate
tools to assemble the frame.
Tools required
- 5/32 in or 4 mm Allen wrench
- Adjustable wrench
- Level
Dimensions
The following diagram shows the dimensions of the frame.
Install the frame in an area that allows for service and
maintenance access to utility connections, piping, filters, and
traps.
65.5 in
Unistrut mount holes
(3/8 in diameter)
20 in
20 in
32 in
1
3
2
4
Parts Diagram
The following diagram allows you to correctly identify each part for easy assembly.
B
C
A
The water heater or boiler units can be mounted using the in-
line or back-to-back setup.
Additional
hole for
In-line Setup
extra support
Depending on the number of the water heater
Note
or boiler units, assemble the extension kits to the
rack to add more installation space.
1
4
Part list
2
No.
Descriptions of parts
Fixed bar 17.7 in
1
5
2
Post bar 64.4 in
Base frame 32 in
3
4
Fixed bracket (upper)
8
5
Fixed bracket (middle)
6
6
Fixed bracket (under)
3
7
Reinforcement plate
7
8
Tapping screw (washers set, 5x12)
9
9
M10 bolts (3 in)
Back-to-back Setup

Advertisement

loading

Summary of Contents for Navien Ready-Link-Rack

  • Page 1 M10 bolts (3 in) Note Although the floor mounting hardware is not included with this kit, you must fix the Ready-Link-Rack securely to the floor to complete installation. Use appropriate anchor bolts (3/8 in) to fix the frame to the ground.
  • Page 2 Note Although the floor mounting hardware is not included with this kit, you must fix the Ready-Link-Rack securely to the floor to complete installation. Use appropriate anchor bolts (3/8 in) to fix the frame to the ground. Before fixing the frame to the ground using anchor bolts, ensure that the anchor bolts protrude above the surface of the ground by at least 2 in (50 mm).