ES4435.1 Current Source Load Board
User's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES4435.1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ETAS ES4435.1

  • Page 1 ES4435.1 Current Source Load Board User’s Guide...
  • Page 2 The data in this document may not be altered or amended without special noti- fication from ETAS GmbH. ETAS GmbH undertakes no further obligation in rela- tion to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license.
  • Page 3: Table Of Contents

    4 ETAS Contact Addresses ........
  • Page 4 Contents ETAS ES4435.1 Current Source Load Board - User’s Guide...
  • Page 5: Introduction

    The components, connectors and conductors of the ES4435.1 Cur- rent Source Load Board may carry dangerous voltages. These voltages may even exist if the ES4435.1 is not installed in the ES4408.1 Load Chassis or the ES4408.1 Load Chassis is powered off.
  • Page 6: Features

    ETAS Features The ES4435.1 Current Source Load Board is a 3 U plug-in board for the ES4408.1 Load Chassis and is used to simulate low current loads up to 150 mA. A total of seven boards of the type ES4434.1 Configurable Load Board and ES4435.1 Current Source Load Board can be installed in the ES4408.1 Load...
  • Page 7 ETAS Introduction Fig. 1-1 shows the block diagram of the ES4435.1 Current Source Load Board. Current Source 12 Current Source 0 Current Source 13 Current Source 1 Current Source 14 Current Source 2 Current Source 15 Current Source 3 Current Source 16...
  • Page 8: Basic Safety Instructions

    Please adhere to the safety instructions in this manuals to avoid injury to yourself and others as well as damage to the device. 1.2.1 Correct Use ETAS GmbH cannot be made liable for damage which is caused by incorrect use and not adhering to the safety instructions. 1.2.2 Labeling of Safety Instructions...
  • Page 9: Identifications On The Product

    (see "Taking the Product Back and Recycling" on page 10) 1.3.1 KC Mark With the KC mark attached to the product and its packaging, ETAS confirms that the product has been registered in accordance with the product-specific KCC guidelines of the Republic of Korea.
  • Page 10: Taking The Product Back And Recycling

    The user is obliged to collect the old devices separately and return them to the WEEE take-back system for recycling. The WEEE directive concerns all ETAS devices but not external cables or batteries. For more information on the ETAS GmbH Recycling Program, contact the ETAS sales and service locations (see "ETAS Contact Addresses"...
  • Page 11: Hardware

    • "The Load Signals at the Backplane Connectors" on page 14 Current Sources The current sources of the ES4435.1 Current Source Load Board are controlled MOSFET current sources for regulating current – the input operational amplifier is addressed via a 10-bit D/A converter with a serial input.
  • Page 12: Calibrating The Circuit

    Hardware ETAS 2.1.3 Calibrating the Circuit The current sources can be calibrated by ETAS. The order data is shown below: Order Name Short Name Order Number Calibration Service for ES4435 K_ES4435 F-00K-106-387 Configuration in LABCAR-RTC To configure the individual current sources of the ES4435.1 Current Source Load Boards used: •...
  • Page 13: Assigning "Load In Slot X" To Connector "Load N

    Please note that the connector numbering does not correspond to the slot numbering (see the following table)! Slot Connector Load 15 Load 14 Load 13 Load 12 Load 11 Load 10 Load 9 Assignment: Slot x → Connector “Load n” Tab. 2-2 ES4435.1 Current Source Load Board - User’s Guide...
  • Page 14: The Load Signals At The Backplane Connectors

    Slot n:b18 Slot n:load 11 Slot n:b14 Slot n:load 24 Slot n:c18 Slot n:load 12 Slot n:c14 GND board Slot n:c10 Slot n:load 13 Slot n:a15 Tab. 2-3 Load Signals and Backplane Connectors ES4435.1 Current Source Load Board - User’s Guide...
  • Page 15: Technical Data

    ETAS Technical Data Technical Data This section contains the technical data of the ES4435.1 Current Source Load Board Current Sources No. of channels Maximum output current 150 mA ±3 mA Overvoltage protection to 60 V Environmental Conditions Operating temperature 5 °C to 35 °C (41 °F to 95 °F)
  • Page 16 Technical Data ETAS ES4435.1 Current Source Load Board - User’s Guide...
  • Page 17: Etas Contact Addresses

    Germany WWW: www.etas.com ETAS Subsidiaries and Technical Support For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/contact.php ETAS technical support WWW: www.etas.com/en/hotlines.php...
  • Page 18 ETAS Contact Addresses ETAS ES4435.1 Current Source Load Board - User’s Guide...
  • Page 19: Index

    Current intensities 11 Current sources 11 Waste Electrical and Electronic Equip- ment 10 WEEE take-back system 10 ETAS Contact Addresses 17 Features 6 Operation mode set 12 Product Back 10 Pull-Down 11 Pull-Up 11 ES4435.1 Current Source Load Board - User’s Guide...
  • Page 20 Index ETAS ES4435.1 Current Source Load Board - User’s Guide...

Table of Contents