Advertisement

Quick Links

Portable H2 Server
W
henever,
H2 Water
User's Manual / Warranty
YWH-070
W
herever
with
10
11
2
3
4
4
5
7
9

Advertisement

Table of Contents
loading

Summary of Contents for Youngwoo Waterline Portable H2 Server

  • Page 1: Table Of Contents

    YWH-070 Portable H2 Server henever, herever with H2 Water User’s Manual / Warranty Precautions In Use Parts Identification and Functions How to Recharge Must-Read Before Use How to Use How to Maintain How to Store Troubleshooting Product Specification...
  • Page 2: Precautions In Use

    Precautions In Use 주의 Please remove the charging cable while using the device. The charging cable may be broken. Do not put any materials into the device except water. Do not apply an excessive power to the body or accessories. Check there is no water leaking while operation.
  • Page 3: Parts Identification And Functions

    Parts Identification and Functions Please check that there are all accessories in the package. Body DC Adaptor Front View Top Cover to protect the body while not used. DC Adaptor Tip Bottle Stopper Silicon Gasket Silicon Gasket Rear View Plug-End Power Button...
  • Page 4: How To Recharge

    How to Recharge The battery must be fully charged before use. (Charging hour : approx. 90~120min.) This device contains built-in rechargeable battery, so you can use it as portable. The fully charged battery lead to use 20 times X 5min for hydrogen creating.
  • Page 5: How To Use

    How to Use Remove the Top Cover. Top Cover Drain out the liquid inside and wash it several times. Remove the Cap of 500ml water to connect. Hold tightly the bottle and connect the device on it clockwise direction. Notice Do not use a plastic bottle which size is bigger than 500ml and all of glass bottle.
  • Page 6 Press the Power Button to operate. While the device is operated, the bottle stopper will blink in blue LED light. The operation will be automatically stopped after 5 minutes. Once of operation is enough to reach a high concentrated hydrogen. ●...
  • Page 7: How To Maintain

    How to Maintain General Maintenance(after use) Inside of the body Open the Top Cover, and wash out the water inside the Electrolysis Chamber. Keep some amount of fresh water stayed in electrolysis chamber be in always wet condition, and cover with Top Cover. Do not use neutral detergent, chlorine bleach, scouring pad.
  • Page 8 Press the Power Button to operate the device. After used, wash out the device several times. Few drops of vinegar or Some amount of Citric acid Fully fill warm water into electrolysis Warm water chamber with few 50~60℃ drops of vinegar, or some amount of citric acid.
  • Page 9: How To Store

    How to Store General method for storing the device. Use the Top Cover and disconnect the Power Plug. Place the device in a well-ventilated place. Long-time unused If you don’t use the device for more than weeks, fill inside of the Electrolysis Chamber with a bit of water, then seal it with Top Cover.
  • Page 10: Troubleshooting

    Troubleshooting PROBLEM CAUSE TROUBLE SHOOT Power failure Lack of battery power. Recharging is required. The bottle stopper blinks amber if the battery is low. Water leakage The bottle is not Getting proper fixing. properly fixed to the body. The size of bottle neck Get proper bottle neck thread is different.
  • Page 11: Product Specification

    Product Specification Product Portable Hydrogen Water SERVER Model name YWH-070 INPUT:AC100-240V, 50/60Hz, 0.3A Rated voltage OUTPUT:DC5V, 2A Power consumption Weight 196g Size Ø69mm Height 103mm Hydrogen dissolving methods Electrolysis Concentration of 5min – Approx. 900ppb, 10min (5min x 2) – Approx. 1100ppb dissolved hydrogen Operation time 5min in operation...