Error Messages - Newco AKPA-3 DB-T HW Installation And Operation Manual

Tea brewer & hot water faucet machine
Table of Contents

Advertisement

PROGRAMMING
SEQUENCE OF PROGRAMMING STEPS FOR THE DIGI-BREW CONTROLLER
∗ Depress and hold QUALITY button until display lights up (Approx. 10 seconds).
∗ You are now in the Program Mode. Functions to be programmed appear in the order in which they are shown in the following
table.
∗ Use the QUALITY button to cycle through the functions to find the one you wish to change.
∗ Use the TEA1/2 button to lower the displayed value and the TEA 1 button to raise the value. Press QUALITY
button to store the changed value and advance to next function.
∗ If the Brewer detects no activity for approx. 60 seconds it will exit the Program Mode, except as noted below.
CODE
FUNCTION TO SET
1A
Brew 1 volume (Left Button)
1b
Brew 2 volume (Right Button)
2
Visa-brew time
3
Water Temperature *1
4
Auto Arm
5A
Pre-infusion 1 mode
5b
Pre-infusion 2 mode
6
Pulse brew mode
6A
Pulse brew 1 time *2
6b
Pulse brew 2 time *3
7A
Audible alert mode
7b
Audible alert no. of beeps
9A
Filtering flow rate
9b
Filter capacity *4
10
Number of Brews
11A
Auto Warmer Shutoff
11b
Time Interval before shutoff
12A
Power mode
12b
Power shutdown time *5
End
None *6
*1
Brewer will remain in this sequence indefinitely until CANCEL button is pressed.
*2
Hidden if pulse brew mode is OFF or brew 1 time is OFF.
*3
Hidden if pulse brew mode is OFF or brew 2 time is OFF.
*4
Hidden if filter flow rate is OFF.
*5
Hidden when power save mode is normal.
*6
Program mode will time out in 15 seconds at end of programming sequence.

ERROR MESSAGES

The following table explains the error messages which may be encountered on the brewer. The error messages may be cleared by going
into the program mode, using the brew buttons to display "Clr" and then pressing the cancel button.
ERRORMESSAGE
DESCRIPTION
Er1
Fill run error
Er2
Heater run error
Er3
Shorted probe
Er4
Open probe
Ful
Filter limit reached
SET VALUE OPTIONS
OFF, 30 – 255 ounces
OFF, 30 – 255 ounces
OFF, 30 seconds – 2 ½ minutes
170 °F – 205° F
ON or OFF
ON or OFF
ON or OFF
ON or OFF
ON or OFF
ON,OFF, 1 – 9
OFF, 0.25 – 1.00 gal. / min
OFF, 0.50 – 2.50 gal. X 100 2000
ON or OFF, Clr
ON or OFF
0-4:15
Normal, Power Save, Power Down
30 minutes – 4 hours
N/A
The fill solenoid has either run for more than six minutes on the initial tank fill or 3 minutes
in normal operation.
The tank heater has run for more than 30 consecutive minutes.
Short in the thermistor circuit.
Break in the thermistor circuit.
The selected filtering capacity of the filter has been reached
10
Issued August 2013
TEA BREWER
30 ounces
60 ounces
203 Degrees F
On(Continuous)
.25 GPM
gallons
Normal
CAUSE
1:45
On
Off
Off
On
1:15
3:15
On
N/A
Off
N/A
N/A
N/A