Advertisement

Quick Links

PSP SERIES
USER MANUAL
CONTENTS
1. Product Introduction............................................................ 1
2. Safety Information..................................................... 3
3. Technical Specification................................................ 7
4. Panel Controls and Indicator........................................ 9
6. Operating Instruction with Keypad Input............................... 13
7. Disposal.................................................................... 17
8. Rectification of Faults................................................. 18
9. Maintenance............................................................... 19
via RS232 Interface..................................................................... 21
i
PAGE
PSP SERIES
USER MANUAL
Declaration of Conformity
We
GOOD WILL INSTRUMENT CO., LTD.
No. 7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan.
declares that the below mentioned product
PSP-603, PSP-405, PSP-2010
Are herewith confirmed to comply with the requirements set out in the Council
Directive on the Approximation of the Law of Member States relating to
Electromagnetic Compatibility (89/336/EEC, 92/31/EEC, 93/68/EEC) and Low
Voltage Equipment Directive (73/23/EEC, 93/68/EEC). For the evaluation regarding
the Electromagnetic Compatibility and Low Voltage Equipment Directive, the
following standards were applied:
◎ EMC
EN 61326-1:
Electrical equipment for measurement, control and laboratory use --
EMC requirements (1997+A1: 1998)
Conducted and Radiated Emissions
EN 55011: 1998
Current Harmonic
EN 61000-3-2: 1995+A1: 1998+A2: 1998
Voltage Fluctuation
EN 61000-3-3: 1995
-------------------------
-------------------------
-------------------------
-------------------------
◎ Safety
Low Voltage Equipment Directive 73/23/EEC & amended by 93/68/EEC
IEC/EN 61010-1: 2001
EN 60950 :1992+A1:1993+A2 :1993+A3 :1995+A4 : 1997+A11: 1997
IEC 60950:1991+A1:1992+A2 :1993+A3 :1995+A4 : 1996
Electrostatic Discharge
EN 61000-4-2: 1995+A1:1998
Radiated Immunity
EN 61000-4-3: 1996
Electrical Fast Transients
EN 61000-4-4: 1995
Surge Immunity
EN 61000-4-5: 1995
Conducted Susceptibility
EN 61000-4-6: 1996
P.F.Magnetic Field
EN 61000-4-8: 1993
Voltage Dips/ Interrupts
EN 61000-4-11: 1994
ii

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSP-603 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tequipment PSP-603

  • Page 1: Table Of Contents

    No. 7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan. declares that the below mentioned product 5. Functional Description of Operation Element……...……….. 12 PSP-603, PSP-405, PSP-2010 6. Operating Instruction with Keypad Input....... 13 Are herewith confirmed to comply with the requirements set out in the Council 7.
  • Page 2 PSP SERIES PSP SERIES USER MANUAL USER MANUAL SAFETY TERMS AND SYMBOLS FOR UNITED KINGDOM ONLY These terms may appear in this manual or on the product: NOTE: This lead/appliance must only be wired by competent persons WARNING. Warning statements identify condition or WARNING: THIS APPLIANCE MUST BE EARTHED practices that could result in injury or loss of life.
  • Page 3: Product Introduction

    PSP SERIES PSP SERIES USER MANUAL USER MANUAL 1. Product Introduction The wire which is coloured Brown must be connected to the The PSP series is a programmable switching power supply with backlit terminal marked with the letter L or P or coloured Brown or Red. liquid crystal display built to the latest technological standards.
  • Page 4: Safety Information

    PSP SERIES PSP SERIES USER MANUAL USER MANUAL -Thunderstorms or storm conditions such as strong electrostatic fields, 2. Safety Information etc. Note: Damage caused by failure to observe the operating Any use other than above description may leads to damage to the unit; instructions voids the guarantee.
  • Page 5 PSP SERIES PSP SERIES USER MANUAL USER MANUAL are contained in this user manual. While proceeding the operation of power supplies, the wearing of The instrument is constructed to Protection Class I. It is equipped with metal or other conducting jewelry such as chains, bracelets, rings, etc. a VDE-approved power supply with safety cable and may only be used is not recommended.
  • Page 6: Technical Specification

    USER MANUAL The power supply outputs and connecting leads, sockets and terminals 3. Technical Specifications must be protected from being touched directly. In addition, the leads PSP-603 PSP-405 PSP-2010 Model used must be sufficiently insulated and voltage-proof and the contact Operating voltage 115/230 VAC ±15%...
  • Page 7: Panel Controls And Indicator

    PSP SERIES PSP SERIES USER MANUAL USER MANUAL 4. Panel Controls & Indicator Environmental Conditions Front Panel Indoor use, altitude up to 2000m. Operating Ambient Temperature 0℃ to 40℃. Environment 1) 4 mm safety sockets: 1a negative connection "-", 1b positive Relative Humidity 80%(Maximum).
  • Page 8 PSP SERIES PSP SERIES USER MANUAL USER MANUAL Front Panel Rear Panel Figure 4-1 Figure 4-2...
  • Page 9: Functional Description Of Operation Element

    PSP SERIES PSP SERIES USER MANUAL USER MANUAL 6. Operating Instructions with keypad input 5. Functional Description of Operating Elements With its continuously adjustable voltage and current settings, this A) Basic setting power supply can be used universally in school, work, hobby, and other a) Connect the AC power cable to the AC power socket and ensure applications.
  • Page 10 PSP SERIES PSP SERIES USER MANUAL USER MANUAL power upper limit will again be set at "200 W". To the "V LIMIT " key is now pressed for longer than 2s, complete the input, press the "ENTER" key. An the voltage upper limit will again be set at "rating inadvertently wrong-set limit setting can be erased/reset voltage".
  • Page 11: Disposal

    PSP SERIES PSP SERIES USER MANUAL USER MANUAL the saved multiple value. from the display. If the " F " key is pressed, the symbol "fine" For example: appears on the display. Set the output voltage as 10.00V, the save value of +% is 105, LOCK Pressing the "LOCK"...
  • Page 12: Rectification Of Faults

    PSP SERIES PSP SERIES USER MANUAL USER MANUAL 8. Rectification of faults 9. Maintenance With the PSP series power supply you have acquired a new generation The following instructions are executed by qualified personnel only. To avoid measuring instrument constructed to the latest technological standards. electrical shock, do not perform any servicing other than the operating instructions However, faults can occur.
  • Page 13: Appendix: Connecting The Programmable Power Supply Via Rs232 Interface

    Ensure that the chassis ground of the equipment is connected to PSP-405 2.10A±50mA 1.80A±50mA Off the chassis ground of the external device. PSP-603 1.40A±50mA 1.20A±50mA Off Do not use more than 15m of cable to connect devices to a PC. 2.10A±50mA 1.80A±50mA Off...
  • Page 14 PSP SERIES PSP SERIES USER MANUAL USER MANUAL RS232 message terminator No connection Receive Data(RxD) (input) The power supply has 25 commands available. Every command is end Transmit Data(TxD) (output) up with <cr> (ASCII 0Dh or ACSCII 0D 0A acceptable). The return +12V Input(*) (input) message <cr>of the power supply is CR/LF (ASCII 0D 0A).
  • Page 15 PSP SERIES PSP SERIES USER MANUAL USER MANUAL ffffff = The status of power supply at present. F101000 f = the relay status 0: OFF 1:ON f = the temperature status 0: Normal 1: Overheat Not yet getting into Lock mode. f = the wheel knob status 0: Normal 1: Fine Not yet getting into Remote mode.
  • Page 16 PSP SERIES PSP SERIES USER MANUAL USER MANUAL Function: Function: The present output current, the unit is A. The maximum voltage limit at present, the unit is V. Syntax: Syntax: A<cr> HEX = 41 0D U<cr> HEX = 55 0D Explain: Explain: When the message of A<cr>is sent to the power supply from computer,...
  • Page 17 PSP SERIES PSP SERIES USER MANUAL USER MANUAL The contents consist of the uppercase I, the numeral from 0 to 9 and Syntax: decimal. Further details is described as follows: HEX = 46 0D F<cr> Explain: i.ii = The maximum current limit at present, the unit: A When the message of F<cr>...
  • Page 18 PSP SERIES PSP SERIES USER MANUAL USER MANUAL Example: Example: The present output voltage is at 20.00V, and the wheel knob status is The present voltage limit is at 30V, and the wheel knob status is at at normal, the SV+<cr> message is sent to the power supply, the normal, the SV+<cr>...
  • Page 19 PSP SERIES PSP SERIES USER MANUAL USER MANUAL Example: Example: The present voltage limit is at 30V, and the wheel knob status is at The present current limit is at 3.00A, and the wheel knob status is at normal, the SU-<cr> message is sent to the power supply, the voltage normal, the SI-<cr>...
  • Page 20 PSP SERIES PSP SERIES USER MANUAL USER MANUAL Example: Example: The present current limit is at 2.50A, the SIM<cr> message is sent to The present load limit is at 100W, and the wheel knob status is at the power supply, the current limit of which will become 5.00A. normal, the SP-<cr>...
  • Page 21 PSP SERIES PSP SERIES USER MANUAL USER MANUAL sent to the power supply, the wheel knob status will become Fine. *KOE Function: Set the Relay status to ON. Function: Syntax: Set the wheel knob to Normal status. HEX = 4B 4F 45 0D KOE<cr>...
  • Page 22 PSP SERIES PSP SERIES USER MANUAL USER MANUAL Explain: Function: To obtain +% value. When the message of D<cr> is sent to the power supply from computer, the power supply will return the following message Syntax: immediately HEX = 42 0D B<cr>...
  • Page 23 PSP SERIES PSP SERIES USER MANUAL USER MANUAL The contents consist of the uppercase B, and the numeral 0 or 1. Explain: Further details is described as follows: Whether the first q is at % mode? 0: No 1:Yes When the message of SD-<cr> is sent to the power supply from computer, the power supply will decrease one unit from the present Whether the second q is at +% mode? 0: No 1: Yes...
  • Page 24 PSP SERIES PSP SERIES USER MANUAL USER MANUAL Example: *SD- SV 12.34 Function: Set output voltage to 12.34V To decrease one unit from the present setting of -%. Syntax: HEX = 53 44 2D 0D SD-<cr> Function: Explain: Set voltage limit. When the message of SD-<cr>...
  • Page 25 PSP SERIES USER MANUAL Explain: The power supply will set desired up-limit value of the current when the command is received. Example: SU 1.25 Set current limit to 1.25A Function: Set power limit. Syntax: SP xxx<cr> x is a number between 0 and 9. Explain: The power supply will set desired up-limit value of the power when the command is received.

This manual is also suitable for:

Psp-405Psp-2010

Table of Contents