Advertisement

Quick Links

6
EQUATOR
COMBI OVENS
PRECISIO
BUILDER'S SPECIFICATIONS
Part C: Maintenance manual
- WARRANTY -
In order to guarantee this equipment, we recommend that you comply with the
MANUFACTURER'S INSTRUCTIONS in this manual.
However if you can not undertake the required maintenance operations, our installation and
service network is available to provide you with a personalized contract.
- WARNING -
The product delivered to you complies with current standards. If any modifications are made
the manufacturer cannot accept any responsibility whatsoever. The manufacturer can not be
held responsible in the event of an incorrect use of the appliance.
Keep your manuals.
3BE390692NM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Precisio Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bonnet Precisio Series

  • Page 1 EQUATOR COMBI OVENS PRECISIO BUILDER’S SPECIFICATIONS Part C: Maintenance manual - WARRANTY - In order to guarantee this equipment, we recommend that you comply with the MANUFACTURER’S INSTRUCTIONS in this manual. However if you can not undertake the required maintenance operations, our installation and service network is available to provide you with a personalized contract.
  • Page 2: Table Of Contents

    PARAMETER SETTING / MAINTENANCE PROGRAMME............... 24 11.1 06 MAINTENANCE .............................24 11.2 061 MAINTENANCE: Usual maintenance......................25 11.3 0611 MAINTENANCE: Technical assistance .....................26 11.4 06111 MAINTENANCE: Technical assistance ....................27 BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 3: Presentation Of The Screen Drop-Down Menus

    STOP: It stops the cycle in progress after RETURN: Comes back to the inlet confirmation and turns back to the inlet menu menu BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 4: Functioning And Marking Of The Maxi Relay Card

    Motor supply gas Precision oven, inlet remove the resistance and connect the boiler Fuse: This only temperature sensor. protects against a capacity ventilator failure BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 5: Parameter Setting Of The Uc Relay Card

    * Set the new card in place. * Check the configuration key. - Without keeping the customer parameters: * Change the whole card. * Programme the configuration key. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 6: Parameter Setting Of The Configuration Key

    EQ4+202/1.PC.G Gas Précisio oven 20 GN2/1 Push the switch of the UC relay card on ON (towards the left) Close the facia board. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 7: Parameter Setting Of The Facia Board (In Case The Whole Card Has Been Changed)

    FREE mode to the INTER and LOCK modes, limiting the possibility of CONTRAST: modification of personalised recipes. BUZZER VOLUME: RETURN BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 8: Operating Failures

    - E52: Set duration or core temperature at 0. - E53: Ventilation: failure to operate. - E67: Activated gas safety inlet. - E68: Capacity temperature at + 290° C. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 9: Changing The Equipment From One Gas To Another

    G30 / G31 28-30 / 37 37 and 50 Belgium G20 / G25 20 / 25 2E(s)B G30 / G31 28-30 / 37 BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 10: Change Over From One Gas To Another

    2E(s)B 28-30 * The category change is only to be carried out under the responsibility of the Company T.G.C.P. or our local agent. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 11 2E(s)B 28-30 * The category change is only to be carried out under the responsibility of the Company T.G.C.P. or our local agent. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 12: Gas Flow-Rates And Powers

    Code: 368 551 Ø = 5.7 mm Code: 368 550 1 groove on injectors Ø 5.7 Code 368 603 368 604 368 605 368 606 BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 13 Identification of nozzles 3 grooves on the nozzle Ø 4.1 1 groove on the nozzle Ø 8.5 2 grooves on the nozzle Ø 3.75 BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 14 Page 13 3BE390692NM – 10/10 Positioning of the nozzle and the air distancing ring Air distancing ring Nozzle Regulating valve BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 15: Maintenance

    - Check the hydraulic circuit and condenser. 6.1 SERVICING THE CONDENSER The water injection nozzle and the temperature sensor are to be checked and cleaned regularly. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 16: Verification Of Temperature Sensors

    175.84 176.21 176.57 176.94 177.31 177.68 178.04 178.41 178.78 179.14 179.51 179.88 180.24 180.61 180.97 181.34 181.71 182.07 182.44 182.80 183.17 183.53 183.90 184.26 184.63 184.99 185.36 185.72 186.09 186.45 BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans...
  • Page 17 Check the sensor insulation between one of the leads and the metal part with the ohmmeter gauged at 20 megohms (a value over 15 megohms). Check the continuity between the screen and the metal part of the sensor. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans...
  • Page 18: Door Adjustment And Closing

    At this stage, if the procedure has been properly executed, the door should be at the same height as the oven top. If not, readjust before the next step BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans...
  • Page 19: Level Ovens

    - Make sure that the oven is properly secured to the floor. Level the oven. - Door closed. Level the door by unscrewing both fixation screws of the upper hinge on the oven. Screws BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans...
  • Page 20 - Bring the upper distance between the door and the capacity to the lower part of the door by loosening the fixation screws of the lower hinge. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans...
  • Page 21: Renewal Of The Driving Shaft Gasket

    - Install the hub puller (3 points with flat tips) and extract the turbine Turbine Hub puller Driving shaft gasket - Remove the gasket BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 22 - Run the motors (before reassembling the turbines) to check proper positioning of the ring and the gasket (they must not rotate together with the driving shaft). - Reassembly : carry out the procedure in reverse order. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans...
  • Page 23: Front Line Parts

    Lighting transformer BT 230V 50HZ 12V 308479 1A fast acting fuse 309335 Fuse 3.15 Amps 309407 Ribbon 309417 Fuse 6.3 x 32 T10 Amps SCHURTER 309506 BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 24 10.2 x 15 diameter 2 mm thick metal-asbestos plastic gasket 318033 Heating resistance capacity + immersion heater gasket 366461 Lighting glass sheet gasket 366557 Door stop 366572 Synthetic filter 386087 BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 25: Parameter Setting / Maintenance Programme

    0847 RETURN For access to the INSTAL – ASS menu, enter the BASS (Bonnet ASS) code. - Bring the « vertical lift » to the same level (lower knurl). - Validate with the upper knurl: the cursor (a dash underlining the letter) appears under the first letter.
  • Page 26: 061 Maintenance: Usual Maintenance

    - Cleanliness of air inlet and discharge apertures. - That aspiration is with fresh cool air. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans 77292 MITRY MORY Cedex...
  • Page 27: 0611 Maintenance: Technical Assistance

    A first actuation of the right knurl causes the activation (maintained) of the outlet for one minute. In case of a second action before one minute has elapsed drop out results. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans...
  • Page 28: 06111 Maintenance: Technical Assistance

    Notes E8 and E9: The operation of the corresponding outlet in the outlet menu enables the operation of corresponding inlets with display of 0 and 1 to be checked. BONNET GRANDE CUISINE Registered Office: Rue des Frères Lumière - Z.I Mitry Compans...

This manual is also suitable for:

Equator 6