Digital panel meter for thermocouples and pt100 (28 pages)
Summary of Contents for Erma Electronic SSI 9006
Page 1
SSI 9006 Di gi tal Pa nel Me ter for Ab so lu te En co ders with Syn chron-Se ri al-In ter fa ce In struc ti on Manual...
Page 2
War ran ty For de li ver ed pro ducts our "All ge mei ne Lie fe rungs- und Zah lungs be din gun gen" are ef fec ti ve. In no event we or our supp liers shall be li ab le for any ot her da ma ges what soe ver (in clu ding, wit hout li mi ta tion, da ma - ges for loss of bu si ness pro fits, bu si ness in ter rup ti on or ot her pe cu nia ry loss) ari sing out of or ina bi li ty to use this pro duct.
Description The di gi tal con ver ter Mo del SSI 9006 is an in stru ment to con vert da tas of ab so lu te en co ders with Syn chro nous- Se rial- In ter face (SSI) in an ana log out put si gnal. Si - mul ta ne ous, it can car ried out an alarm point con trolling.
2. Safety instructions Safety instructions This in stru ment is pro du ced in ac cor dan ce with Class II of IEC 348 and VDE 0411. When de li vered the in stru ment has been te sted to meet all func ti ons descri bed. Be fo - re in stal ling the in stru ment plea se read the moun ting and ser vicing in struc ti ons.
3. Mounting Mounting 3.1. Place of operation At ten ti on must be payed to the pro tec tion against hu mi di ty, dust and high tem pe ra tu - res at the place of ope ra ti on. 3.2.
4. Electrical connections Electrical connections 4.1. General instructions • It is for bid den to plug or un plug con nec tors with vol ta ge applied • At tach in put and out put wi res to the con nec tors only wi thout vol ta ges applied •...
4. Electrical connections 4.3. Connection and pin assignment All in puts and out puts are con nec tors, de signed as plug- in screw ter mi nals. n.c. signal input digital inputs LED1 LED2 LED3 ERMA-METER 11 11 12 RS 485 alarm4 alarm3 alarm1 alarm2 Pin as signment: Power supply DC (+)
4. Electrical connections 4.4. Connection of absolute encoder Encoder 4.5. Connection of digital user inputs Di gi tal in put 1 • ac ti ve => Con nec ting Screw Ter mi nal 24 to 26 • Con nec ting to Ground, low ac ti ve Di gi tal in put 2 •...
5. Startup procedure 4.7. Con nec ti on of RS 485 in ter fa ce 11 11 12 A(+) B(-) 4.8. Connection of power supply voltage 4.8.1. Supply voltage 18 ... 36 V DC Startup procedure At ten ti on must be paid that the po wer supply vol ta ge applied will agree with the vol ta ge no ti ced at the name pla te.
6. Pushbuttons- and LED-functions Pushbuttons- and LED-functions The re are four push but tons in the front. The se push but tons can have dif fe rent func ti - ons. The func ti ons of the push but tons can be used for pro gram ming and for ser vice. LED1 6 decades display LED2...
7. Modes Modes The ope ra ti on and the pro gram ming of the pa nel me ter is or ga nized in se veral sta tes: • Ope ra ti on level • Ac cess- code level • Pro gramm level 7.1.
7. Modes Parameter 0-14 Function of pushbutton “-” By pressing Pressing during 3 sec. No function Display value of encoder Display MAX value Display MIN value Display hold value Display alarm point 1 Change alarm point 1 Display alarm point 2 Change alarm point 2 Parameter 0-15 Function of pushbutton “+”...
7. Modes 7.3. Programming level The sta te “pro gramm level” be co mes ac ti ve by en te ring the right ac cess- code. The ac cess- code must be con firm by pres sing the push but ton .
8. Procedure of programming Procedure of programming The pro ce du re of pro gram ming is or ga nized in se veral dif fe rent steps. Ac cess to the se lec tion of the pro gram ming levels •...
8. Procedure of programming Lea ving the pro gram ming level • Pres sing the push but ton un til the dis play shows “xEnd” For ex amp le: “0End” => lea ving pro gram ming level 0 For ex amp le: “2End” => lea ving pro gram ming level 2 •...
Page 19
8. Procedure of programming Default Param. Description Setting range value Function of digital user input 1 0 -> No function 1 -> Reset MIN/MAX value 0-11 0 .. 11 2 -> Taring of encoder 3 -> Clear tara value of encoder 4 ->...
8. Procedure of programming Default Param. Description Setting range value Function of pushbutton “+” 0 -> No function 1 -> Display value of encoder 2 -> Display MAX value 0-15 0 .. 6 3 -> Display MIN value 4 -> Display hold value 5 ->...
8. Procedure of programming 8.4. Programming level of alarms P-02 Default Param. Description Setting range value Alarm output 1, data source 0 -> Alarm 1 off 1 -> Alarm 1 to value of encoder 2-00 0 .. 4 2 -> Alarm 1 to maximum value 3 ->...
Page 22
8. Procedure of programming Default Param. Description Setting range value Alarm output 3, high or low 0 -> Contact closed by low limit 2-13 0 .. 3 1 -> Contact closed by high limit 2 -> Contact open by low limit 3 ->...
8. Procedure of programming 8.4.1. Alarm output functions Data sour ces of the alarms: • Va lue of the en co der • Ma xi mum va lue • Mi ni mum va lue • Hold va lue In di ca ti on of alarms •...
8. Procedure of programming 8.4.2. Alarm high setpoint normally closed to high limit normally opened to high limit alarm value alarm value- hysteresis alarm watched signal operate delay time release delay time 8.4.3. Alarm low setpoint normally closed to low limit normally opened to low limit alarm value +...
8. Procedure of programming 8.5. Programming level of serial interface P-04 The pa ra me ters of the pro gram ming level P-04 exists anly by pa nel me ters with the op ti on se ri al in ter face. The in ter face mo duls are bi di rec tio nal and works at the sla ve mode.
9. Software functions Software functions 9.1. Master/Slave-Mode Ma ster- Mo de Pa ra me ter 0-02 have to be pro gram med to 0 For rea ding the va lue of the en co der the clock is ge ner ated by the in stru ment. The clock fre quen cy can be pro gram med to 1 MHz, 500 kHz, 200 kHz or 100 kHz.
9. Software functions Dis play ran ge with chan ging of the zero point The push but ton have been pressed by a dis play of 2048 2048 1024 -1024 2. Zero point ad just ment wi thout sign: Pa ra me ter 0-04 have to be pro gram med to 0 Ex amp le: Ab so lu te En co der SSI- En co der, sin gle turn...
9. Software functions 9.3. Incremental measurement A re la ti ve mea su re ment can be made by using the in cre men tal mea su re ment func - tion. Ac ti vating the in cre men tal mea su re ment func tion will hap pen, that a in cre men - tal mea su re ment va lue will be sto red to a non- vo la ti le EE PROM even af ter swit ching of the in stru ment.
9. Software functions Dis play the mi ni mum and ma xi mum va lue • By pro gram ming as data sour ce of the dis play (pa ra me ter 0-09) • By ac ti vating the di gi tal in put 1 or 2 (pa ra me ter 0-11 and 0-12) •...
Page 32
The data from the en co der shall also be sent to a com - pu ter which pro ces ses both the sta tus bits as well as the po si ti on data. The SSI 9006 shall only pro cess the po si ti on data.
10. Error codes 9.8. Display test When ac ti vating the dis play test all seg ments of the dis play are light on. The dis play shows “8.8.8.8.8.8.” Ac ti vating the dis play test by: • Di gi tal in put 1 (pa ra me ter 0-11) •...
Field of application : class 2 : overvoltage protection II : in conform with 89/336/EWG : NSR 73/23/EWG 12. Ordering Information SSI 9006 - Reserve Front design No logo Power supply 5 V DC, ± 10%, isolated 12 V DC, ± 10%, isolated 18 ..
Page 40
ERMA - Elec tro nic GmbH Max-Eyth-Str. 8 D-78194 Im men din gen Te le fon (+49 7462) 2000-0 (+49 7462) 2000-29 email info@erma-elec tro nic.com www.erma-elec tro nic.com...
Need help?
Do you have a question about the SSI 9006 and is the answer not in the manual?