WARNING

TECHNICAL CHARACTERISTICS AND SPECIFICATIONS

ELECTRICAL CONNECTIONS

Power supply
Input
Fuse

HYDRAULIC CIRCUIT

Maximum supply water temperature
Minimum supply water temperature
Minimum supply water flow rate
Maximum supply water pressure
Maximum priming depth
PERFORMANCE
Maximum flow rate
Nominal flow rate
Maximum pressure
Nominal pressure
Maximum water outlet temperature
Maximum reaction force on the spray gun
Sound pressure level - Uncertainty
Sound power level
Operator hand-arm vibration - Uncertainty
PUMP OIL
WEIGHT AND DIMENSIONS
Length x width x height
Weight
Diesel tank
Detergent bottle capacity
(1)
Measurements in agreement with 60335-2-79.
(2)
Also see the corresponding oils table.
The characteristics and specifications are guidelines only. The manufacturer reserves the right to make all modifications to the equipment deemed necessary.
20
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
Read and keep in mind that indicated in the INSTRUCTION
MANUAL - SAFETY WARNINGS.
(W)
(°C - °F)
(°C - °F)
(l/min - USgpm)
(bar - psi)
(m - ft)
(l/min - USgpm)
(l/min - USgpm)
(bar - psi)
(bar - psi)
(°C - °F)
(N)
(dB(A))
(dB(A))
(m/s
)
2
(mm - in)
(kg - lb)
(l - USgal)
(l - USgal)
PW 250 HC - IP 2500 HS
230 V
1~ 50 Hz
2300
16 A
40 - 104
5 - 41
12 - 3,2
8 - 116
0 - 0
8 - 2,1
6,6 - 1,7
150 - 2175
110 - 1595
90 - 194
16,5
  (1)
80 - 0,7
  (1)
96
  (1)
1,73 - 0,24
(2)
ENI MULTITECH THT
580 x 440 x 930 - 22,8 x 17,3 x 36,6
43 - 95
4 - 1,06
0,35 - 0,09