a) Single Line LED:
This is the standard operating mode and does not make use of
the Orange conductor. The LED is Red when the reader is idle and
flashes when a card is presented. The LED turns Green when the
Brown conductor is pulled low by the access control panel.
b) Dual Line LED:
This mode makes use of both the Brown and Orange
conductors. The Brown conductor controls the Red LED and
the Orange conductor controls the Green LED. LED states are
determined by the access control system option and capability.
WIEGAND
Wire Color
RED
BLACK
GREEN
WHITE
BROWN
ORANGE
YELLOW
BLUE
VIOLET
DRAIN
c) Read Mode:
In regards to contactless smart card credentials, the reader will
only read and output the credential's Card Serial Number (CSN)
when the Violet conductor is pulled low (connected to ground).
Otherwise, the reader will only read and output the credential's
programmed Sector data.
Unused conductors should be trimmed, isolated and taped
back to prevent unintended current flows. Apply positive
voltage only to the Red DC Conductor.
Function
DC (8 -14 VDC)
Ground
DATA 0
DATA 1
RED LED (a)
GREEN LED (b)
NOT USED
BEEPER
READ MODE (c)

SHIELD GROUND

CV-7600 SERIES - BLE BLUETOOTH CARD READER
Cable Requirements:
a)
24 AWG minimum, multi-conductor stranded with an overall
foil shield, for example Belden 9535 or similar, supporting the
five conductors comprising the physical layer of the Wiegand
interface (power, ground, data 0, data 1, and/or beeper and LED).
Alternatively, Belden 9539 or similar, for all reader functions.
Contact your access control system manufacturer for their
specific requirements. Per the SIA's Wiegand specification,
maximum cable length is 500 feet (152 m).
b) Output Formats:
Wiegand (industry standard 26-bit Wiegand and custom
Wiegand formats).
c) Grounding:
Shield (drain) continuity must run from the reader to the access
panel. Shield (drain) and reader ground must be tied together at
the access panel and connect to an earth ground at one point.
d) Power:
Reader may be powered by the access control panel. A linear
power supply is recommended for best operation. 8 to 14 VDC,
12 VDC at the reader is best.
e) Read Mode:
For sector data reads, do not connect the Violet conductor
(leave it high). For CSN reads, pull the Violet conductor low
(connect the Violet conductor to ground).
Reader Model
CV-7600
CV-7605
CV-7615
CV-7630
CREDENTIAL
Model
CV-MBT
CV-MCS
CV-MKT
IN S TA LL ATION INSTRUCTIONS
Read Range
1 foot
5 feet
15 feet
30 feet
Description
BLE Mobile Credentials
Mobile Clam Shell Cards
Mobile Key Fob, 2K memory
Page 3 of 5