PerfomancePro Artesian Pro Series Owner's Manual

Low rpm pumps

Advertisement

Quick Links

PUMP MODEL: ________________________
SERIAL #: ____________________________
DATE PURCHASED: ___________________
Retain this information for future reference.
For questions regarding installation, operation or maintenance
5976 SE Alexander St., Ste F, Hillsboro, OR 97123
P (503) 356-5888 F (503) 356-1660 E sales@performancepropumps.com
WWW.PERFORMANCEPROPUMPS.COM
call (503) 356-5888
OWNER'S MANUAL
ARTESIAN PRO
LOW RPM PUMPS

Advertisement

Table of Contents
loading

Summary of Contents for PerfomancePro Artesian Pro Series

  • Page 1 OWNER’S MANUAL ARTESIAN PRO LOW RPM PUMPS PUMP MODEL: ________________________ SERIAL #: ____________________________ DATE PURCHASED: ___________________ Retain this information for future reference. For questions regarding installation, operation or maintenance call (503) 356-5888 5976 SE Alexander St., Ste F, Hillsboro, OR 97123 P (503) 356-5888 F (503) 356-1660 E sales@performancepropumps.com WWW.PERFORMANCEPROPUMPS.COM...
  • Page 2: Important Safety Instructions

    Important Safety Instructions Please read all instructions completely before installing or operating the pump. Save this manual for future reference regarding installation, operation, maintenance and troubleshooting of this pump. Please note the safety warning symbols as noted below: This warning symbol indicates the potential for personal injury or damage to the pump! Please be cautious! This symbol indicates a hazard which if not avoided could result WARNING...
  • Page 3 Understanding priming and pump operation The Basics Your pump is powered by an electric motor that directly a ects your water ow rate. When the electric motor is turned on it utilizes centrifugal force to generate velocity of the water. The water then ows into the strainer pot from the water source, ltering out debris.
  • Page 4 Ensure the vault is properly ventilated. 6. The pump ports are 3” slip on both the inlet and discharge ports. The Artesian Pro series o ers 2” or 3” tting sizes.
  • Page 5: Installation

    Installation After thorough inspection, carefully remove the pump from the box. Secure the pump on a solid, at foundation. A covered location is always best and care should be taken to ensure adequate ventilation. See installation tips for bene cial tips. Install a ball or swing type check valve as needed to facilitate pump disconnection, ow control and servicing.
  • Page 6 Electrical Before wiring any part of the motor be sure the power is disconnected. It is recommended that wiring be performed by a licensed electrician or professional serviceperson. WARNING If pump has a factory preinstalled cord, wiring has already been set and this step is not needed; unless voltage change is required in which case the cord will need to be removed and steps followed below.
  • Page 7: Maintenance

    Maintenance Cleaning the basket: The strainer basket in the priming pot should be inspected and cleaned at least one (1) time per week, more often if excessive debris is present in the operating environment. Turn o your pump and disconnect from the electrical source by unplugging or turning o the breaker.
  • Page 8: Pump Disassembly

    Pump Disassembly All moving parts are located in the rear sub-assembly of this pump. Tools required: 1. 3/32 inch Allen wrench 2. 7/16 inch open end wrench 3. 9/16 inch open end wrench 4. Small and large athead screwdrivers 5. #3 Phillips screw driver Rear Sub-assembly 7/8”...
  • Page 9 Parts Replacement and Pump Assembly 7/8” Hex Bolts (4) Union 1 1/8” Hex Bolts (6) Assembly Bracket Bracket o-ring Diffuser Quick Clamp Set Screws Mechanical Seal Union Assembly Slinger Motor Lid o-ring Bracket Impeller Bore o-ring Set Screw Diffuser Motor Base with Gasket Diffuser o-ring Drain Plug...
  • Page 10 Winterization Winterizing your pump is necessary if freezing temperatures occur in your geographic area for extended periods of time. If freezing tempuratures are not common but may on occassion drop below freezing, it is advised to follow winterization procedure to protect your pump. Freezing tempuratures cause water to expand and may result in damage to the pump, plumbing, and other connected components resulting in costly repairs.
  • Page 11: Troubleshooting

    Troubleshooting The following troubleshooting tips support the most common issues. For additional assistance, please contact techhelp@performancepropumps.com or 503-356-5888. PROBLEM KNOWN ISSUE TRY THIS Pump is not priming No water in strainer pot Fill strainer pot with water and close lid. Ensure plumbing valves are open.
  • Page 12 Parts 7/8” Hex Bolts (4) Union 1 1/8” Hex Bolts (6) Assembly Bracket Bracket o-ring Diffuser Quick Clamp Set Screws Mechanical Seal Union Assembly Slinger Motor Lid o-ring Bracket Impeller Bore o-ring Set Screw Diffuser Motor Base with Gasket Diffuser o-ring Drain Plug Volute with Gasket...
  • Page 13 Parts 7/8” Hex Bolts (4) Union 1 1/8” Hex Bolts (6) Assembly Bracket Bracket o-ring Diffuser Quick Clamp Set Screws Mechanical Seal Union Assembly Slinger Motor Lid o-ring Bracket Impeller Bore o-ring Set Screw Diffuser Motor Base with Gasket Diffuser o-ring Drain Plug Volute with Gasket...
  • Page 14: Performance Data

    Performance Data...
  • Page 15: Warranty

    Limited Warranty This Artesian Pro series product is warranted to the Purchaser (defined herein as the original end user) to be free of defects in construction and workmanship at the time of purchase. In the event this product malfunctions within three years (for fresh water use) or one year (for use with salt water...
  • Page 16: Protect Your Investment

    PROTECT YOUR INVESTMENT! Exposure to the elements can result in corrosion and reduced service life of your pump. Protect your pump motor from the elements today! * Excellent weather protection * Noise abatement * Easy to assemble * Customizable precut knockout sections * Sturdy construction * Fits Artesian, Artesian 2, ArtesianPro and Cascade series 15”...