4. DETECTOR PROCEDURE

4-1 RF detector operation

1) Connect the antenna( 3-5, Fig. 1 ) to the RF detector.
2) Turn on the RF detector by Turning the " rotary switch "
( 3-6, Fig. 1 ), ti the in position, the power (RED) led
indicator will be lit.
Turn off the RF detector by Turning the " rotary switch "
( 3-6, Fig. 1 ) to off position, the power LED indicator will no
longer be lit.
3) When the RF meter is turned on it is in ready mode.

4-2 How to use the rotary switch to adjust sensitivity

Turning the rotary switch to find the target device.
Turn the rotary switch clockwise to maximum, goto standby
mode, if receiving stronger environmental then adjust the
rotary switch back, until no more than the first LED is lit.
When all 10 LEDs are lit, it means the meter is closer to the
target, we can change the detector direction, adjusting the
rotary switch back when the signal is strong, in this way, we
can find the target easily.
NOTE:
The FC-2601 is a wireless detector, for any emission
and receiving devices, so when using this meter, it is
recommended to turn off any known signal sources nearby,
for example mobile phones, wireless sharing devices,
radios, modems etc. to ensure the accuracy of detection.

4-3 Buzzer ON/OFF

Press the Buzzer ON/OFF Button once. to select Buzzer ON or
OFF ,when Buzzer sound select to ON and detector signal
more than the 6 led bar, the beep will be sound.