Technical Manual
General Information
This appliance is for boiling water only and is suitable for use in mobile catering vans and trailer.
This appliance is only for professional use and shall be used by qualified people
This appliance is a manual lit LPG fuelled water boiler. It is fitted with a flame failure valve that automatically cuts the flow of gas if the flame
is extinguished.
To maintain peak performance it is recommended that the appliance be regularly serviced.
Safety
All work carried out on this appliance during installation or servicing must be performed by a qualified installer and the connection to the gas
supply must be carried out by qualified installer in accordance with the relevant regulations.
Parts which have been protected by the manufacturer shall not be adjusted by the user.
The siting of the appliance and connection to the gas supply must comply with the Gas Safety Regulation 1995; the requirements of the Fire
Precaution Act 1971; the Health and Safety at Work, etc. Act 1974. Detailed recommendations are contained in BS5440 pt.1:2000;
BS6173:2001 and BS6891:1998.
All LPG equipment consumes oxygen and emits carbon monoxide and should therefore only be used in well ventilated areas.
All connections should be checked for gas soundness. If in any doubt, turn off gas supply immediately.
The body gets very hot in use. Care should be taken not to touch any part of the body, especially near the combustion outlets. Also care should
be taken to keep combustible items (i.e. tea towels) away from combustion outlets.
This appliance is only for professional use and should only be used by qualified people.
Care should be taken when dispensing hot water. To avoid chance of scalding, the cup or teapot should not be held when filling.
Use fresh water each day.
For installation in Ireland please refer to the requirements of I.S. 820:2000 including Amd 1: 2003 for the requirements for natural or LPG
installations at pressures not exceeding 5 bar, from the point of delivery of the gas up to and including the appliance in non-domestic premises.
Installation
Please refer to the installation regulations in force in the country in which the appliance is installed.
This appliance should be located in a well ventilated area to prevent the occurrence of unacceptable concentrations of substances harmful to
health. It should be located out of reach of customers and also away from accidental contact by staff.
It should be placed on a fire resistant surface. We recommend 1.5mm stainless steel as a base.
There should be a gap of 125mm to any wall. These walls should also be fire resistant.
It is recommended that there is a gap above the urn of at least 600mm.
The feet should be fixed to the worktop by means of 4mm bolts or pop-rivets. Stability of urn should be checked before use each time.
The appliance is ready to connect to the gas supply by means of a compression fitting (supplied separately to prevent damage in transit).
On unpacking it should be checked that the thermocouple is not touching any parts of the interior between the valve and the probe.
It is suggested that the urn should be connected to the water supply via a hole in the side of the body. The lid should not be lifted for filling
whilst the urn is in use.
The installation must comply with Local Authority Regulations.
An easily accessible gas cock must be fitted in the gas supply adjacent to the appliance for use in an emergency.
At this stage, leak test the whole system. The Gas Safety Regulation requires that all connections in the gas supply line between the gas supply
and appliance be tested for leaks by means of a drop test and any joints be tested using a leak detection fluid. This must be done before
commencing to commission the appliance.
The parts protected by the manufacturer or his agent shall not be adjusted by the installer
We recommend 47Kg cylinders.
Technical information
Appliance category
Type – A1
Gas type
Supply pressure - 37mb
Setting pressure – 35mb
(These pressures are fixed and cannot be altered on the valve)
DO NOT ALLOW TO RUN DRY
I
3p
G31
Fuller LPG Counter Urns
Country of destination
Net heat input:
F20 (5 gallon)
F44 (10 gallon)
F20/P (5 gallon)
F44/P (10 gallon)
Reduced rate
Date of issue Apr 2018
GB & IE
3.7Kw
5.6Kw
3.9Kw
5.8Kw
2.5Kw