wagner solar Sungo 200 Manual
Hide thumbs Also See for Sungo 200:

Advertisement

Mounting
Connection
Operation
Troubleshooting
Application examples
Safety advice
Instructions
Information about the product
Proper usage
CE Declaration of conformity
Note
Subject to technical change. Errors excepted.
2
Target group
Description of symbols
WARNING!
They contain information on how to avoid the danger
described.
-
WARNING
ATTENTION
Note
-
Disposal
-

Advertisement

Table of Contents
loading

Summary of Contents for wagner solar Sungo 200

  • Page 1 Mounting Connection Operation Troubleshooting Application examples Safety advice Target group Instructions Description of symbols Information about the product WARNING! They contain information on how to avoid the danger Proper usage described. WARNING ATTENTION CE Declaration of conformity Note Note Disposal Subject to technical change.
  • Page 2: Table Of Contents

    Contents Overview ....................4 Solar ..................... 39 Installation .................... 5 Arrangement ..................55 Step-by-step parameterisation ............9 10 Heating ....................65 Operation and function ..............10 4.5 Output selection submenu ..............16 11 HQM ....................81 Commissioning ................... 19 12 Basic settings ..................82 13 SD card ....................
  • Page 3: Installation

    Optional functions Installation Arrangement Heating Mounting Solar WARNING! Electric shock! Always disconnect the device from power supply before opening the housing! Note Chap. 2.2...
  • Page 4 Electrical connection Do not use the device if it is visibly damaged! relays WARNING! Electric shock! Always disconnect the device from power supply before opening the housing! ATTENTION! ESD damage! Take care to discharge properly before touching The temperature sensors the inside of the device! To do so, touch a grounded surface such as a radiator or tap! The V40...
  • Page 5: Step-By-Step Parameterisation

    Step-by-step parameterisation 4. Activating optional arrangement functions 5. Adjusting heating circuits and activating optional heating functions 1. Running the commissioning menu 2. Registering sensors Inputs / Modules 3. Activating solar optional functions Selecting menu points and adjusting values Operation and function Buttons »...
  • Page 6 Adjusting the timer Timer In the Day selection Save Continue Adding a time frame: New time frame Start Stop...
  • Page 7 Copying a time frame: Changing a time frame: Copy from Save Removing a time frame: Delete with Yes Adjusting optional functions Resetting the timer: In the Optional functions Add new function Reset with Yes Reset with Yes Output Optional func- tions Add new function...
  • Page 8: Output Selection Submenu

    Function Status Switch Switch in the Inputs / Modules Switch Sensor Function Save function Delete function new function Output selection submenu The Output selection Settings Result...
  • Page 9 Speed control In the Speed Min. Max. Adapter In the Min. In the Max. ® Adapter ® 10,0 10,2 10,4 10,6 10,8 11,2 11,4 11,6 11,8 Relay option Blocking protection Relay 0-10 V option Blocking protection Basic setting / Blocking protection 0-10 V Manual mode In the Signal...
  • Page 10: Commissioning

    Commissioning 1. Language: 2. Units: Commissioning menu 3. Daylight savings time adjustment: Button navigation 4. Time: 5. Date: 6. Selection: System or Scheme Basic systems 7a. Scheme (if 6. = Scheme): 7b. Selection of the solar system Note (if 6. = System): 8.
  • Page 11 Overview of relay and sensor allocation System 1.2.1 System 1.1.1 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 R1; A R1; A System 1.2.3 System 1.2.2 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 R1; A R1; A R2; B...
  • Page 12 System 1.3.1 System 1.3.2 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 R1; A R1; A R2; B R3; C System 1.3.3 System 1.4.1 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 R1; A R1; A...
  • Page 13 System 1.4.2 System 1.4.3 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 R1; A R1; A R2; B R3; C R4; D System 2.1.1 System 2.1.2 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 S1 S6...
  • Page 14 System 2.2.1 System 2.2.2 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 S1 S6 S1 S6 R2; B R2; B R1; A R1; A System 2.2.3 System 2.2.4 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 S1 S6 S1 S6 R3; A R3; A R4;...
  • Page 15 System 2.2.5 System 2.3.1 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 S1 S6 R1; A R2; B R3; A System 2.3.2 System 2.3.3 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 S1 S6 R3; A R1; A R2; B R3; C...
  • Page 16 System 2.3.4 System 2.3.5 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 S1 S6 R1; A R2; B R3; A System 3.1.1 System 3.1.2 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10...
  • Page 17 System 3.2.2 System 3.2.1 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10 System 3.2.3 System 3.2.4 Sensors Relays; PWM/0-10 Sensors Relays; PWM/0-10...
  • Page 18: Main Menu

    Main menu Note Menu structure Main menu Solar Basic setting Arrangement Optional functions Parallel relay Heating Basic settings Note Inputs / Modules...
  • Page 19: Status

    Status Arrangement The Status / Arrangement Heating In the Status / Heating In the Status / HQM Adjustment values Messages Adjustment values In the Status / Messages Everything OK Measured / Balance values In the Status / Meas. / Balance values Restarts Solar The Status / Solar...
  • Page 20 Store (1 / 2 / 3 / 4) Solar / Basic setting / Store (1 / 2 / 3 / 4) Solar / Basic setting Collector (1 / 2 / 3) Solar / Basic setting / Collector (1 / 2 / 3) tMin Collector Store 1...
  • Page 21 Successive loading Minimum runtime Optional functions Spreaded loading option Spread temperature difference between the Relay Note Solar / Basic setting / Relay Bypass The Bypass Type pump Type valve (inverted) Type valve Type Type pump Bypass Bypass switch-on temperature difference Solar / Opt.
  • Page 22 CS bypass External heat exchanger Solar / Opt. functions / Add new function / CS bypass Solar / Opt. functions / Add new function / Ext. HX The CS bypass function Note Output Reference sensor external heat exchanger Switch-on suppression The Reference sensor external heat exchanger Note Note...
  • Page 23 2- and 3-collector systems Antifreeze Target temperature Solar / Opt. functions / Add new function / Antifreeze Solar / Opt. functions / Add new function / Target temp. The Antifreeze Antifreeze switch-on temperature Antifreeze switch-off temperature Target temperature Note External heat exchanger Target temperature Note Backup heating suppression...
  • Page 24 Cooling mode Type system cooling Switch-on temperature difference Switch-off temperature difference Type collector cooling Solar / Opt. functions / Add new function / Cooling mode Collector maximum temperature Emergency shut- down temperature Store cooling option Store cooling option In the Cooling mode System cooling Collector cooling...
  • Page 25 Twin pump Output Runtime Reference relay Flow rate monitoring Solar / Opt. functions / Add new function / Twin pump Flow rate sensor Delay time The Twin pump Heat dump The Heat dump Type Type pump Solar / Opt. functions / Add new function / Heat dump Collector overtem- perature Type valve...
  • Page 26 Flow rate monitoring Pressure monitoring Solar / Opt. functions / Add new function / Flow rate mon. Note Solar / Opt. functions / Add new function / Pressure monit. The Flow rate monitoring Reference relay Store Reference relay The Pressure monitoring Status / Messages Status / Solar / Flow rate monitoring Sta-...
  • Page 27: Arrangement

    Flow and return interchanged Solar / Holiday function FL / RE interchanged Note Flow and return interchanged 0031 !FL/RE interchanged! Flow and return interchanged Maximum store temperature In the Store Type system cooling Holiday function Type collector cooling Solar / Expert Store cooling option Store cooling option The Expert...
  • Page 28 Optional functions Reference relay Overrun Output Overrun time Reference relay Delay Output Duration Reference relay Note Mixer Note Parallel relay Arrangement / Opt. functions / Add new function / Mixer Arrangement / Opt. functions / Add new function / Parallel relay The Mixer Mixer target temperature Interval.
  • Page 29 Heat exchange Arrangement / Opt. functions / Add new function / Heat exchange The Heat exchange Output temperature difference Timer TMin Note Solid fuel boiler Arrangement / Opt. functions / Add new function / Solid fuel boiler The Solid fuel boiler Output Set temperature difference Target temperature...
  • Page 30 Circulation The Circulation Arrangement / Opt. functions / Add new function / Circulation Thermal Timer Thermal + Timer Demand Demand + Timer Timer Therm. + Timer Demand + Timer Note Note Return preheating Arrangement / Opt. functions / Add new function / Ret. preheat. The Return preheating...
  • Page 31 Function block Arrangement / Opt. functions / Add new function / Function block Thermostat function Sensor T function Note Note Reference output Mode OR mode NOR mode AND mode NAND mode...
  • Page 32: Heating

    Irradiation switch Return mixing function Arrangement / Opt. functions / Add new function / Irrad. switch Arrangement / Opt. functions / Add new function / Ret. mixing The Irradiation switch Inverted The Return mixing Heating Switch-on temperature difference Interval Tset Maximum boiler return temperature Switch-off temperature difference TMax...
  • Page 33 Activated demands will be available for selection in the output allocation channels of the backup heating in heating circuits and heating optional functions. This way, several heating circuits and optional functions can demand the same heat source. Heating / Shared rel. Relay option Relay Relay...
  • Page 34 Curve Heating curve selected Interval Heating system submenu In the Heating system Mode Curve Linear In the Linear TOutdoor 1 The Constant TFlow 1 TOutdoor 2 TFlow 2 Heating curves TFlowmax TFlowmin In the Room factor Room thermostats Room therm. (1 ... 5) Outdoor temperature in °C In the Room Day Night correction...
  • Page 35 Timer RTH(1 … 5). Sensor in the Type Correction Special operation Cooling set room temperature Correction Note Room thermostat option Room thermostat Set room temperature HC off Switch Type Sen. RTH Summer operation Day: Summer temperature day Correction timer Timer Day / Night: Daytime on Daytime off...
  • Page 36 In the Demand Standard Demand Standard Remote control Mode Fern Room control unit Mode Demand Heat- ing / Shared relays Heat- ing / Shared relays / Demand Holiday App: In the Day / Off Starting optimisation Mode Stop- ping optimisation Backup heating Backup heating In the Thermostat...
  • Page 37 The Cooling Energy saving operation In the Outdoor outdoor temperature cooling In the External switch The Energy saving operation In the both In the Cooling system the Switch-off difference Break time Runtime In the Linear Linear The Constant Heating / Heating circuits / New HC... / Internal or Module 1 … 2 TFlow Timer Dew point switch...
  • Page 38 10.3 Optional functions Note In the Demand Standard Demand Standard Demand Heating/ Shared rel. Adjustment values Heating/ Shared rel. / Demand Note Thermal disinfection Heating / Opt. functions / Add new function / Th. Disinfection One Sensor Demand Monitoring period Disinfec- tion temperature Disinfection period...
  • Page 39 Overrun time Heating / Opt. functions / Add new function / DHW heating Thermal mode Sensor 1 Zone mode Sensor 2 Timer SFB off Solar off Set temperature Set store temperature Manual heating Note BAS off DHW preheating The DHW preheating Flow rate sensor Starting speed Temperature sensor...
  • Page 40: Hqm

    10.4 Screed drying Rise time with the Heating / Screed drying Start Phase Remaining time Cancel Note Flow rate sensor Note Inputs / Modules Flow rate sensor Heating / Screed drying Flow rate Relay Fluid type Concentration Carryover Alternative unit Unit Conversion factor In the HQM...
  • Page 41: Basic Settings

    Sensor new HQM… HQM / new HQM... Function Save function Save function Delete function Unit Delete func- tion Basic settings new HQM… Function In the Basic settings Switch Switch Basic settings Firmware updates Update? Please wait Note Note Starting the logging SD card Completing the logging process Remove card...
  • Page 42: Manual Mode

    Storing controller adjustments Save adjustments In the All outputs... Please wait Done! Loading controller adjustments Load adjustments Please wait Done! Note Remove card... SD card Note Auto Manual mode Manual mode In the Manual mode User code Inputs / Modules / Modules In the User code 16.2 Inputs...
  • Page 43: Troubleshooting

    Inputs / Modules / Inputs IMP1 Note Switch Fern BAS Impulse none ATTENTION! Damage to the device! Make sure no voltage is applied! Switch Inverted CS sensor offset Type Offset Reset back Inputs Note Troubleshooting WARNING! Electric shock! Always disconnect the device from power supply be- fore opening the housing! !Sensor fault °C °F...
  • Page 45: Accessories

    Accessories DL3 Datalogger SD3 / SDFK Smart Display / GA3 Large Display ® DL2 Datalogger ® SP10 Overvoltage protection device EM Extension Module ® ® VBus / USB & VBus / LAN interface adapters TS10 Dew point switch ® ® ®...
  • Page 46 67, 71 Wagner Solar GmbH Distributed by: Industriestr. 10 35091 Cölbe www.wagner-solar.com © All contents of this document are protected by copyright.

Table of Contents