Parascope Mini-Bubbler Finish Kit
Item
Part Number
1
**
2
**
3
**
4
**
5
**
6
**
7
**
8
004-627-5452-00
1.
Choose location for the Fountains. NOTE: Maximum
water depth that it can be installed is 18", and the
fountain can be plumbed no closer than 6" from the
front edge of the step or shelf area or 8" from the
back or side of the step or shelf area. Figure 1
2.
Dig trenches for 1½" Sch. 40 plumbing to the location
of the Fountain allowing for the top of a 2" 90 to be
22" for 18" water depth to 12" for 8" water depth below
top of finished gunite level.
3.
Glue the 2" Fountain Housing Shaft to a 90 on the
bottom and a slip cap on top.
4.
At the location of the fountain dig a vertical shaft deep
enough and trench to accommodate the Fountain
Housing Assembly.
5.
Each Fountain must be fed by a separate 1½" Sch.
40 pipe and gate valve to allow each to be adjusted
separately (Figure 2A, 2B, 2C on page 3). Glue the
Fountain Housing to the feed pipe so that it is plumb.
6.
Pressure-test the Fountain Housing to code (pressure
to remain on system until plaster).
295 East Corporate Place • Suite 100 • Chandler, AZ 85225
Toll Free: 1.800.621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397
Paramount@1Paramount.com • www.1Paramount.com
004-027-8808-00 REV 111213
PARASCOPE MINI-BUBBLER WATER FEATURE
Description
Bubbler Nozzle
Retainer
Body
Plaster Cap
Bubbler Shaft 20"
Housing Shaft 24" x 2"
Plastic Stop
Fountain Tool
PLUMBING FOR POOLS
INSTALLATION MANUAL
1
2
3
4
7.
Backfill the plumbing trenches with dirt to maintain
its vertical alignment. If there is a vertical trench in the
side wall of the pool, pack dirt around the bottom end
of the Fountain Housing to hold it plumb and stabilize
it. NOTE: If the Fountain Housing is not plumbed
vertically it will not retract properly.
8.
DO NOT HEAT BEND OR ANGLE the riser for the
Fountain when installing on a sloped surface, such as
a beach entry. Doing so will not allow you to install the
fountain or may cause the Fountain Shaft to bind and
not raise or lower.
FIG. 1
1 1/2" LINE
FROM PUMP
5
6
7
8
WATERLINE
MINIMUM OF 8" FROM
BACK WALL OF LEDGE
CAP
PARAMOUNT RISER
TOP OF 90 SHOULD
BE NO LESS THAN 8"
BELOW TOP OF
FINISHED GUNITE
MINIMUM OF 6" FROM
FRONT EDGE OF LEDGE