Eldom Invest HPWH 120 Technical Description, Installation, Operating And Maintenance Instructions

Heat pump water heater 120 and 150 intended for wall mounting

Advertisement

Quick Links

HEAT PUMP WATER HEATER
120 and 150
intended for wall mounting
TECHNICAL DESCRIPTION
INSTALLATION, USE AND MAINTENANCE INSTRUCTIONS
v20190723

Advertisement

loading
Need help?

Need help?

Do you have a question about the HPWH 120 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eldom Invest HPWH 120

  • Page 1 HEAT PUMP WATER HEATER 120 and 150 intended for wall mounting TECHNICAL DESCRIPTION INSTALLATION, USE AND MAINTENANCE INSTRUCTIONS v20190723...
  • Page 2: Environment Protection

    WARNING! Read carefully these instructions before installation and use! SAFETY, MAIN REQUIREMENTS Before proceeding with the installation and commissioning of the water heater, it is essential to read the full text of this booklet. It is intended to familiarize you with the water heater, the rules for proper and safe use, with the minimum necessary maintenance and servicing activities.
  • Page 3: Technical Description

    appliance, contact your local city government, your household waste disposal service or the shop where you purchased the appliance TECHNICAL DESCRIPTION The heat pump water heaters are intended for domestic use, in households and can provide heated water from the common plumbing system at the same time for several consuming points - kitchen, bathroom etc.
  • Page 4 Table 1 HPWH 120(I) 120(I)S 150(I) 150(I)S Model Capacity group Nominal heat output of the heat 1500 W pump Nominal power of the electric 2000 W heater Nominal electric power of the heat 500 W pump Maximum electrical power of the 850 W heat pump Nominal voltage...
  • Page 5 „I“ - the water tank of the indoor unit is made of chromium-nickel alloy steel. “S” – the water heater has a heat exchanger The maximum allowable refrigerant system pressure in the heat pump water heaters is 2.7 MPa. They are tested and designed to operate at pressures lower than 2.7 MPa. For this purpose, a valve is installed in their construction to prevent pressure exceeding the maximum permissible Heat pump water heaters are designed to heat water, except through a heat pump system, also with a 2000 W electric heater.
  • Page 6 Fig.2 WARNING! Failure to comply with the requirements for fastening to the wall of the premise may cause damage to the appliance, to other appliances and to the premise in which the appliance is placed, corrosion of the casing or heavier damage and harms. In such cases, any damages and harms are not subject to the warranty obligations and are at the expense of the person who failed to observe the requirements of this instruction.
  • Page 7 Fig.3 PREPARATION OF REFRIGERANT PIPES ATTENTION! Before installation, check the following: а) Copper pipes intended for installation of air-conditioning systems are used. Outer pipe diameter: 1/4 "and 3/8" with adequate insulation (at least 8 mm thick) Fig. 4, suitable for use with refrigerant R134a Fig.4 b) Never use pipes with a wall thickness of less than 0.8 mm;...
  • Page 8 Description Outer diameter [mm] Thickness [mm] 1/4“ 6,35 3/8“ 9,52 b) Remove the protection nuts of the refrigerant nipples on the indoor unit (make sure there are no dirt and moisture); c) Cut the pipes longitudinally with a suitable tool, avoiding the formation of a seam and damages. The cut must be perpendicular to the axis of the pipe (Fig.
  • Page 9 h) Connect the pipes to the refrigerant nipples on the indoor unit by screwing the nuts with appropriate torque. When installing, make sure that the pipes are properly leveled to avoid damage. If the torque is insufficient, there will be a refrigerant leak. It is advisable to use a torque wrench, in this case, use the data in the table: 6,35 mm (1/4") Approximately 150-200 kgcm (15-20 Nm)
  • Page 10 a) Remove the plugs of the two-way, three-way valve on the outdoor unit and the service valve. Check that both of the outdoor unit valves are closed; b) Connect a vacuum pump to the service valve. c) After opening the pump valve, turn it on and let it run. Create a vacuum for about 40-45 minutes. d) Check that the arrow on the pressure gauge shows pressure equal to 1 bar (or -76 cm Hg);...
  • Page 11 than 0.5 MPa, the installation of a pressure reducing valve (reducing valve) is mandatory. In case local regulations require the use of additional devices that are not included in the kit and are not included in the package, they must be purchased and installed as prescribed. The indoor unit is complete with a combined non-return safety valve.
  • Page 12 The safety valve, if necessary, also serves to drain water from the water tank. This is done as follows: The indoor unit is switched off from the electric grid by means of the auxiliary device and, for  safety reasons, the electric fuse in the phase circuit to the water heater is switched off. Cold water supply to the appliance is stopped - close the crane (4 of Figure 12).
  • Page 13 WARNING! It is obligatory to install such device in the power supply circuit of the appliance which, in the conditions of category III overvoltage, ensures complete disconnection of all poles. The conductors of the circuit between the device and the input electrical terminals of the appliance must not be interrupted by another breaker or fuse.
  • Page 14 Fig.13 1-Outdoor unit; 2-Fan; 3-Compressor; 4- Four-way valve; 5- Terminals outdoor unit; 6-Pressure switch high pressure ; 7-Electronic thermo-regulating valve; 8- Ambient temperature; 9- Compressor inlet; 10- Evaporator Inlet; 11- Compressor outlet; 12- Temperature sensors; 13- Sensor 1 lower; 14- Sensor 2 upper;...
  • Page 15 Depending on their intended use, use the following types of cables Purpose Cable Type Power supply to the appliance 3G 2.5mm Power supply to the outdoor unit 3G 1.5mm H05RN-F Communication 3G (0,5-0.75)mm H05RN-F All cables need to be secured against shifting using cable clamps. After connecting and fastening the cables, the plastic covers of the indoor and outdoor unit are placed in their places and secured with the screws, taking care to free placing of the cables, sensors and capillary tube of the thermal switch.
  • Page 16 WARNING! For the correct functioning of the electronic control and the operation of the water heater it is necessary to use only the temperature sensors supplied in the set. If the sensors are not installed or incorrectly installed, some of the mode menus will not be displayed on the screen.
  • Page 17: Displayed Information

    light switch for turning on and off of the appliance on its control panel. The indoor unit can only be switched on again in working regime after full removal of any moisture The rules for checking the anode protection and replacement of the anode and the removal of lime should be observed both during and after the warranty term of the appliance.
  • Page 18 the screen. Pressing the up or down arrows will scroll the screen up or down respectively to show the next rows Main screen - appliances without heat exchanger 1-Additional features of the boiler; 2-Modem is connected to the Internet; 3-Timers are enabled; 4- Time;...
  • Page 19 On the main screen is displayed a stylized drawing of the water heater (boiler, indoor unit) with two heat exchangers, an outdoor unit and installations with solar collector. The heat exchanger connected to the outdoor unit is the condenser around the water tank and the one connected to the solar collector –...
  • Page 20: Information Screens

    ATTENTION If the image from the picture above is missing in the middle of the screen, we recommend restarting the thermal regulator by turning off the boiler power supply and then turning it on again! INFORMATION SCREENS Hourly statistics - Pressing the Enter button when the thermoregulator is in the "Main screen", switches to viewing additional information screens.
  • Page 21 1-Timer status for additional heating with electric heater. If this option is enabled, the next time the heater will be switched on or off is displayed; 2-Temperature up to which the boiler will be heated; 3- Consumption of electricity at daily tariff; 4-Sign for hot water consumption during the day; 5-Anode protector condition;...
  • Page 22 Snd/Rcv – Sent / received data packets over the Internet  Errors – Data exchange errors registered  No WiFi modem - There will be a message if there is no WiFi modem connected to the  controller, Version - Pressing the down arrow from the screen “WiFi connections” switches to the ...
  • Page 23 No heat pump There is no connection to the outdoor unit module. Check the power supply and the interface cable to the outdoor unit module Frozen boiler When the power supply is turned on, the water in the water heater has a negative temperature and may have frozen.
  • Page 24 repaired Disconnected Failure in the thermo-sensor for ambient temperature. It is disconnected or turned off. The heat pump stops working but can be switched on again after the fault has been repaired. TA short Failure in the thermo-sensor for ambient temperature. There is a short circuit. circuit The heat pump stops working but can be switched on again after the fault has been repaired...
  • Page 25 below the visible part of the screen, there will be a down arrow. If there are more rows above the visible part of the screen, there will be an arrow pointing upwards. Settings display with parameter change - After entering this screen, a blue marker frame is displayed on the first parameter.
  • Page 26 ATTENTION! The solar installation is always ready for operation. Even when the water heater is in the "Off" mode when there is heat in the solar collector, the circulation pump will be switched on to discharge the heat! To support the solar installation when there is insufficient heat, the water heater can use the heat pump and electric heater.
  • Page 27 When selecting the item Turned off, the heat pump and the electric heater will not be switched on. The solar system continues to operate normally to prevent overheating of the solar collector. The normal functioning of the protection modes also continues: protection against freezing of the water tank and solar collector and overheating protection of the solar collector by automatic activation of the mode Vacation for discharge of accumulated energy.
  • Page 28 When using the heat from the solar installation, the temperature threshold up to which the water heater will be heated is 85 ° C measured by sensor t2. After this threshold the circulation pump will be switched off in order not to transfer more heat to the water heater. When selecting the mode Vacation, only the solar installation and the protection modes will remain activated.
  • Page 29 Adjustment of timers for additional heating with Heat Pump and / or Electric Heater (Menus Timers 1 and Timers 2) - Time intervals in which additional heating is allowed by means of the heat pump and / or the electric heater. When a timer is active and the current moment is within its range, the heat pump and / or the electric heater will switch on to heat the water by using the temperature set in column "Temp"...
  • Page 30 Beginning EL Rates- Set the starting times of 2 different tariffs rates. This is important for proper information of consumpted electricity! Solar Protection (NHPC-V4-2 only) Menu for setting the solar installation protection mode. Set parameters: Auto Holiday mode – When this field is checked, it is ...
  • Page 31 point mode, which allows you to set the required parameters. Pressing the top button will exit this function without changing the status of the WiFi module Service menus The controller also has several service menus to adjust the operating parameters of the heat pump outdoor unit.
  • Page 32 Incorrect transportation;  Poor storage;  Incorrect use;  Water parameters beyond the permissible quality standards for drinking water and in  particular: chloride content is above 250 mg / l; its conductivity is below 100 μS / cm S / cm and / or the pH is outside the range of 6.5-8 for water heaters with an enamelled water container;...