  • Page 1 Operating Instructions DC Servo Barrier Gate S10 SFMCU MicroDrive V1.0...
  • Page 2: Table Of Contents

    1.Brief Introduction Contents SUNFRE S10 DC Brushless Servo motorized barrier gate, the 1. Brief Introduction............2 newly designed, maintenance free with exclusive SFMCU 2 . Te c h n i c a l D a t a ..........2 MicroDrive unit offers 100% more torque, 100% duty, are the 3.
  • Page 3: Mechanism Structure

    high quality and maximum ease of use, and which allow the barrier in 7*24 hours non-stop usage. 3.4 SPEED ADJUSTABLE Our DC servo barrier gate allows you to set opening and closing speed according to requirements. Shorter arm, the faster speed can be set.
  • Page 4: Mechanical Part Installation And Adjustment

    6.Mechanical Part Installation and Adjustment going up, which mean the spring force is well balanced. 6.1. Installation of cabinet Controller Wiring and Instructions Please select the correct type of barrier ate according the specifications Controller interface explanations 7.1. of the place, and then fix the barrier cabinet with expansion bolts. (refer to Figure 3) Expansion Bolts Press bars...
  • Page 5: Controller Auto-Detect After Power-On Description

    toggled in before delivery, if need to change the input voltage, please This interface is used for battery, the battery can be used to keep toggle the switch cap into correct position before power on . barrier gate working normal when power off. 7.1.2.
  • Page 6: Working Codes Meanings And Error Code Solutions

    10.4.5. Warranty time is over. two screws on balance rotating arm. 10.4.6. Service items are out of our promises. 8.2 Vertical adjustment After 8.1 finished, power on(make sure arm installed), after system 11. Maintenance started, press ‘UP’ button to check the vertical position. If not, please 11.1.
  • Page 7: Appendix Ii : Remote Control Coding

    Appendix III: Wiring Diagram for R&G Light Boom Length(Meter: M) Spring Diameter Φ (mm) Suggested max Interface speed Straight Boom Link Hole Selection 2≥L≥2.5 empty 4≥L≥3 empty 4.5≥L>4 6≥L>4.5 Folding arm 2≥L≥2.5 4≥L≥3 4.5≥L>4 6≥L>4.5 2-Fence Boom 4>L≥3 Appendix IV: Wiring Diagram for up and down 4.5≥L≥4 limit output 3-Fence Boom...
  • Page 8: Procedures

    RS485 communication equipment address (barrier gate or control board) Appendix V: System Menu Setting Procedures LP04: Default DP01: Max open speed range(1-16) The highest speed when opening Power on DP02: Opening brake pulse duration(0-255) R UN 0 Note: The speed need to be controlled to achieve when opening to close position, the bigger the value, the slower the speed controlled, vice verse.
  • Page 9: Meanings

    0 is no arm detection(default), 1 is with arm detection, when no arm detected, barrier gate not working. NP07: Motor forward/Reversal(000/001) Appendix VII Digitron Display Code and Meanings digitron display meaning STAT (START) The system is starting RESU(RESUME) The gate is resetting CHAS(CHACK SENSOR) Sensor check E-PL(ERROR PULSE)