  • Page 1 R32 Full-inverter Dehumidifier INSTALLATION & USER MANUAL...
  • Page 3: Table Of Contents

    SUMMARY For users …………………………………………………………………. P.1-P.6 1. GENERAL INFORMATION 1. 1. Name of Parts 1.2. Spare Part Lists 1.3. Dimension 2. OPERATION 2.1.Instruction for Controller 3. TECHNICAL SPECIFICATION For installers and professionals …………………………………… P.7-P.17 1. Installation and Maintenance 1.1.Notice before installation 1.2 Instruction 1.3 Trail after Installation 1.4.Daily Maintenance Notice...
  • Page 4 Warning: a. Please read the following tips before installation, use and maintenance. b. Installation, removal and maintenance must be carried out by Professionals in accordance with the instructions. c. Gas leakage test must be done before and after installation. 1.Use a.
  • Page 5 d. Installation must be stopped if any R32 gas leakage, and the unit must be returned to professional maintenance center. 3.Transportation& Storage a. Sealing is not allowed during transportation b. Transporting goods at a constant speed is needed to avoid sudden acceleration or sudden braking, so as to reduce the collision of goods.
  • Page 6: General Information

    FOR USER 1. GENERAL INFORMATION 1. 1. Name of Parts Name Controller Feet Air Outlet Air Inlet(on the bottom) Hanging Strip on Wall...
  • Page 7: Spare Part Lists

    FOR USER 1.2. Spare Part Lists Padx3,Feetx4,Drain-pipe x1(2m),Hanging Stripx1,Manual 1.3. Dimension Size(mm) Name Model 7300727 1120 1054 7300728 1220 1154 7300729...
  • Page 8: Operation

    FOR USER 2. OPERATION 2.1.Instruction for Controller SYMBOL DESIGNATION FUNCTION ON/OFF Press to power on or off the dehumidifier 1. For dehumidifier with dehumidifying function only, press “ ” to select Smart /Silence mode. 2. For dehumidifier both with dehumidifying and heating functions (dehumidifier with Mode optional electric heater), press the "...
  • Page 9 FOR USER (2) Both Dehumidifying and Heating Function: Press for 3 seconds, the will flash, before it stops flashing, press to choose circularly, which means “Heating”“Dehumidifying”“Heating + Dehumidifying” A.Dehumidifying Function: Press one time,it can transfer the mode between Default is mode B.
  • Page 10 FOR USER 5. Timer Setting (1) Timer ON setting: When the dehumidifier is on or off, press the “ ” to enter the timer setting; Meanwhile, the symbol light and the are flashing to enter the Timer ON setting. Press the to adjust Timer ON hour setting, then press , you can adjust the minute setting by pressing...
  • Page 11: Technical Specification

    FOR USER 3. TECHNICAL SPECIFICATION Model 7300727 7300728 7300729 Advised pool surface (㎡) * ≤25 ≤40 ≤50 Advised room size (㎡) * Operating air temperature (℃) 10~38 Capacity (l/h) (Air 30℃,RH 80% ) * DER (l/h.kW) (Air 30℃,RH 80% ) * 4.00~3.40 4.53~4.05 4.50~3.68...
  • Page 12: For Installers And Professionals

    FOR INSTALLERS AND PROFESSIONALS 1. Installation and Maintenance This product must be installed by a professional team. The users are not qualified to install by themselves, otherwise the dehumidifier might be damaged and risky for users’ safety. 1.1.Notice before installation The product is only used for dehumidification of the swimming pool and must ensure sufficient air circulation, otherwise the dehumidification function will be ineffective or have little effect.
  • Page 13 FOR INSTALLERS AND PROFESSIONALS 1.1.6. It is strictly forbidden to use or store flammable gases or liquids such as hair spray, paint, gasoline, etc. near the dehumidifier, otherwise a fire may occur. 1.1.7. If any abnormal conditions such as abnormal noise, odor, smoke, leakage, etc., are found, the power should be cut off immediately and contact the local dealer, and do not repair the equipment yourself.
  • Page 14 FOR INSTALLERS AND PROFESSIONALS 1.1.9. In thunderstorms, disconnect the main power switch, otherwise the lightening might damage the unit 1.1.10. Do not wash the equipment directly with water. 1.1.11. Do not use for special purposes such as the preservation of fine arts or academic materials (Otherwise, the quality of the preservation may be reduced).
  • Page 15: Instruction

    FOR INSTALLERS AND PROFESSIONALS 1.2 Instruction This product should be installed in a well-ventilated place 1.2.1.Installation 1.The dehumidifier may be placed on the ground or installed on the wall; 2. When installing on the wall, be sure to use M6 pull-out screws to fix the bracket, the concrete foundation of the selected wall should be firm and strong, and the bracket should be strong enough and rust-proof;...
  • Page 16 FOR INSTALLERS AND PROFESSIONALS Steps to install the foot and place it on the ground: 1. Align the foot to the mounting hole of the dehumidifier chassis and screw it in the clockwise direction (do not flip the equipment to install!). A:Power Cord;B:Drain Outlet(Connected with drain pipes) 2.
  • Page 17 FOR INSTALLERS AND PROFESSIONALS 2. Place the pad on the wall-mounting platform behind the equipment 3. Hang the hanging strip on the back of the equipment on the bracket.
  • Page 18 FOR INSTALLERS AND PROFESSIONALS After hanging the bracket, gently put the equipment until the pad of the bottom rests against the wall. 4. Connect the drain pipe, and connect the power cord according to the wiring diagram A: Power cord; B: Drain outlet( connect the drain pipes)
  • Page 19 FOR INSTALLERS AND PROFESSIONALS 1.2.2. Electrical installation wiring Connect to appropriate power supply, the voltage should comply with the rated voltage 1) of the products. Dehumidifier must be well grounded. 2) Wiring must be connected by professional technician according to the circuit diagram. 3)...
  • Page 20: Trail After Installation

    FOR INSTALLERS AND PROFESSIONALS 1.3 Trail after Installation Please check all the wirings carefully before turning on the dehumidifier. 1.3.1. Inspection before use 1. Check if the dehumidifier is vertically or horizontally placed on the ground or hung on the wall, connected with drain pipe;...
  • Page 21: Trouble Shotting For Common Faults

    FOR INSTALLERS AND PROFESSIONALS 2.TROUBLE SHOTTING FOR COMMON FAULTS Failure Reason Solution No power Wait until the power recovers Dehumidifier doesn’t Power switch is off Switch on the power Fuse burned Check and change the fuse The breaker is off Check and turn on the breaker Evaporator blocked Remove the obstacles...
  • Page 22: Failure Code

    FOR INSTALLERS AND PROFESSIONALS 3.FAILURE CODE Failure Code High pressure protection Low pressure protection Abnormal power supply voltage protection Electric heating overheating protection (manual reset thermostat) Exhaust high temp protection Air out high temp protection Environmental low temp protection Controller failure Air inlet temperature sensor failure Air outlet temperature sensor failure Exhaust gas temp sensor failure...
  • Page 24 Version:C67IDr32...