Bolide BC2036-PTC User Manual

Human body temperature rapid screening device

Advertisement

Quick Links

BC2036-PTC
Human Body Temperature
Rapid Screening Device
User Manual V1.0
BC2036-PTC
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BC2036-PTC and is the answer not in the manual?

Questions and answers

Summary of Contents for Bolide BC2036-PTC

  • Page 1 BC2036-PTC Human Body Temperature Rapid Screening Device User Manual V1.0 BC2036-PTC User Manual...
  • Page 2: Warning, Caution & Note

    After utilization, please cover the lens cap. Caution -To prevent the potential danger of data loss, please copy (backup) the data into computer frequently. Note -Before accurate reading of the data, the thermal imager may need a 3-5 minutes preheating process. BC2036-PTC User Manual...
  • Page 3 -Each thermal imager has been calibrated before delivery. It is suggested to carry out temperature correction annually. Caution -Do not open the enclosure or modify without permission. The maintenance can only be carried out by the personnel authorized by the company. BC2036-PTC User Manual...
  • Page 4: Table Of Contents

    Preview ......................19 Setting......................20 4.6.1 General Setting ..................20 4.6.2 Temperature Measuring Setting ..............24 4.6.3 Temperature Measurement Correction ............. 25 4.6.4 Image Setting ................... 26 4.6.5 TF Card Management ................30 4.6.6 Photo Setting ................... 32 BC2036-PTC User Manual...
  • Page 5 4.6.7 System Setting ..................4.7File Management .................... 4.7.1 Playback ....................4.7.2 Deletion 38 5 Technical Specifications ..................6 In Vivo & Shell Temperature Conversion Table ............7 Common Failure Countermeasures ..............BC2036-PTC User Manual...
  • Page 6: Introduction

    1 Introduction Thank you for choosing the human body temperature rapid screening device. 1.1 Model Identification BC2036-PTC thermal device adopts 25um 160×120 detector with a temperature scope of 20°C~50°C. TE-W400H thermal device adopts 25um 384×288 detector with a temperature scope of 20°C~50°C.
  • Page 7: Standard Configuration

    Alarm image capture Alarm video Isothermal function Temperature measuring setting Common Built-in Materials Emissivity Option List CMOS visible image and saving 2 LED fill lights Infrared and visible image fusion Fusion for High and Low Temperatures 1.3 Standard Configuration Thermal imager (hand strap) Carrying case Lithium battery Lens cap...
  • Page 8: Brief Introduction Of Thermal Imager

    2 Brief Introduction of Thermal Imager 2.1 Function Buttons...
  • Page 9 [1] Power Switch To turn on/off the thermal imager Press this button for more than 3 seconds to turn on/turn off the thermal imager. ! Note: After shutdown, wait at least 10 seconds after re-starting, to ensure the safety of the thermal imager. [2] Select / Auto Button (Tag A) The button with tag A has the three functions below.
  • Page 10 In menu mode, it is for menu selection, and up and down buttons for menu operation of the same level. When there is no sub-menu, adopt the left and right buttons to switch options; when there is a sub-menu, adopt the right button to enter into the next level of menu operation.
  • Page 11: Interface

    2.2 Interface...
  • Page 12: Basic Operation

    [1] USB Interface The interface is for internal debugging. [2] TF Card Slot Adopt standard TF card, e.g. 8G TF card configured at random, for device upgrading and image saving. [3] Video Output For video and audio output. [4] Power Interface External power input interface.
  • Page 13 When inserting the battery, please note that the end with contact spot should be inserted into the battery compartment first. Close the battery cover. and use the device after hearing a "snap".
  • Page 14: Battery Replacement

    ! Note: The device should adopt standard batteries, otherwise the mechanical or electrical performance of the device may be damaged due to incorrect battery size or voltage. 3.1.2 Battery Replacement When showing empty battery and blinking for about 1 minute and 50 seconds, the device displays battery low prompt message, and will automatically shut down after about 10 seconds.
  • Page 15: General Instructions On Safe Battery Use

    3.2 General Instructions on Safe Battery Use ➢ The battery should be stored in the environment at a temperature between -20℃ - 20℃, due to slight self discharge phenomenon during storage of battery, to avoid over discharge that may occur during storage and affect the battery capacity, the battery should be fully charged for storage and charged regularly.
  • Page 16: Monitoring Point Setting

    seconds, the device is initialized and enters the working status. Open the lens cap, aim at the black body from 2 meters away, and adjust the focal length of the lens of the thermal imager, to make the target image clear. Press "A"...
  • Page 17: Thermal Image Saving

    the middle OK button to set the shielding area, and adopt the up, down, left and right direction buttons to move the red box to the position requiring temperature shielding. Press the middle OK button after selection. The system can provide three shielding areas in total.
  • Page 18: Export Of Saved Information

    temperature measurement status. 3.3.5 Export of Saved Information Handle the contents saved in TF card with a card reader, including image export, deletion, format and other operations. ! Note: It is recommended to adopt the formatting function in the firmware software of the thermal imager to format the TF card.
  • Page 19: Operation Guidance

    4 Operation Guidance 4.1 Operation Interface Description 4.1.1 Graphic Interface of Working Status Screen of Thermal Imager Graphic Interface of Working Status Screen of Thermal Imager [1] Power Icon: function icon. [2] Emissivity: Default emissivity set. : Fixed temperature measurement for [3] Reference Temperature Measurement reference.
  • Page 20 [7] Minimum Temperature: The minimum temperature value of the color code. [8] Auto-Enhance: Select auto enhance mode. [9] Manual Enhance: Select manual mode. [10] Color Code: Color code bar. Press up and down buttons to switch the color code bar. [11] Bluetooth: enable Bluetooth function.
  • Page 21: Floating Bar Interface

    4.1.2 Floating Bar Interface Floating Bar Interface Floating bar interface: add, record, take photos, preview and set the temperature measurement target from left to right. 4.1.3 Main Menu Interface Main Menu Interface Main menu item: display the main menu items, including 8 items, i.e. file management, temperature measurement setting, image setting, photo setting, general setting, network setting, TF card management and system setting.
  • Page 22: Sub-Menu Interface

    4.1.4 Sub-menu Interface Sub-menu Interface [1] Dialog Box Name: display the name of dialog box. The name of the dialog box as shown in the example is "Temperature Measurement Setting". [2] Item Title: a dialog box may contain multiple items. As shown in the figure, "Gear", etc.
  • Page 23: Video Recording

    Adding Temperature Measurement Object Menu If " " is selected, press OK button to delete all the temperature measurement objects. ! Note: For deletion of a single temperature measurement object, directly press "A" button to select the temperature measurement object, and then press "C" button to delete. 4.3 Video Recording This function is adopted to save the video in MP4 format.
  • Page 24: Preview

    photos, as shown in the figure below. Photo Taking Audio Recording Prompt If continuous shooting is set in the photographing setting, the continuous shooting icon will be displayed on the status bar when taking photos. 4.5 Preview This function is adopted to preview the files saved. Press OK button to pop out the floating menu, select Preview and press OK button, as shown in the figure below.
  • Page 25: Setting

    4.6 Setting Main Menu Interface 4.6.1 General Setting General Setting Dialog Box Press OK button to pop out the floating panel, select "Setting" option to activate the main menu, select "General Setting" item in the menu, and press OK button to pop out the general setting dialog box.
  • Page 26 Automatic zeroing adjustment interval: set the automatic correction interval, to obtain favorable thermal image and improve the temperature measurement accuracy. The time unit is second. Automatic Zeroing Selection Menu Shortcut button definition: user may customize the functions of setting shortcuts. The system offers options including video recording, image capture, zoom in, zoom out, LCD brightness increasing, LCD brightness decreasing, lighting, addition or deletion of temperature measurement point 1, addition or deletion of temperature measurement...
  • Page 27 Shortcut Button Customize Menu Bluetooth: when Bluetooth is "ON", the scanning and searching device below is in scannable status; when it is "OFF", it is in gray and unselectable status. Select "Scan and Search Device" button to start scanning the Bluetooth device, and display the type and name of the scanned Bluetooth device in the display box.
  • Page 28 Power off duration: when there is no operation within the set time, the thermal imager will automatically turn off the main power to save battery power. The option set as "00 minute" indicates that this function is not enabled. Dialog Box of Power Saving Mode LCD brightness adjustment: adjust the current LCD brightness, and is effective all the time.
  • Page 29: Temperature Measuring Setting

    4.6.2 Temperature Measuring Setting Temperature Measuring Setting Press OK button to pop out the floating panel, select "Setting" option to activate the main menu, select "Temperature Measurement Setting" item in the menu, and press OK button to pop out the temperature measurement setting dialog box. User may set gear, Balow lens, ambient...
  • Page 30: Temperature Measurement Correction

    Reference Temperature Measurement Menu 4.6.3 Temperature Measurement Correction Temperature Measurement Correction Menu For Temperature Measurement Correction item in Temperature Measurement Setting menu, press OK button to pop out temperature measurement correction dialog box. User may set emissivity factor, corrected temperature, distance, humidity and other items.
  • Page 31: Image Setting

    Corrected temperature: it is adopted to modify the temperature measurement value of the temperature measurement object. Distance: set the distance between the thermal imager and the temperature measurement target, to facilitate the accuracy of the temperature measurement. When the distance is less than 10m, adopt the actual distance (to the accuracy of 0.5m) as much as possible.
  • Page 32 favorable image of treatment effect by adjusting the corresponding relationship between temperature and color,to achieve the goal of convenient searching and analysis of thermal failure. When the Auto Enhance mode is activated, you can switch between the AutoEnhance mode and the manual mode. Switch to the maximum and minimum limit of the color bar by pressing "A"...
  • Page 33 Alarm Setting Menu Alarm type: This setting is only valid for temperature measurement. It is divided into OFF, high temperature alarm and low temperature alarm. When the corresponding option is set, the device will give alarm when the temperature of the temperature measurement object is higher or lower than the alarm temperature set.
  • Page 34 Isothermal Setting Menu Isothermal color: display the image display colors within a certain temperature range by the isothermal colors set. Isothermal color: The system provides 9 optional colors. When the isothermal color is set as "Colorless", it indicates that the original color of the screen will not be changed.
  • Page 35: Tf Card Management

    temperature set, the infrared part of the fusion will be displayed as visible light; When selecting fusion for low temperature, and the actual temperature is lower than the fusion temperature set, the infrared part of the fusion will be displayed as visible light. 4.6.5 TF Card Management TF card uninstall dialog box...
  • Page 36 TF card formatting dialog box TF card formatted successfully Press OK button to pop out the floating panel, select "Setting" option to activate the main menu, select "TF card management" item in Setting menu. Uninstall: Uninstall the TF card in the device. Formatting: this function is for TF card formatting.
  • Page 37: Photo Setting

    4.6.6 Photo Setting Photo Setting Menu Press OK button to pop out the floating panel, select the "Setting" option to activate the main menu, and select the "Photo Setting" option in the setting menu. Correlated image capture: this function is to save along with the CMOS visible image corresponding to the current infrared.
  • Page 38: System Setting

    Directory Settings Menu Set the save path for files. Set customize, by month or by date in the directory type column. In preview mode, set the path for file playback according to the directory type here. 4.6.7 System Setting System Setting Menu Press OK button to pop out the floating panel, select the "Setting"...
  • Page 39 Time / Date Format Menu Change the display formats of time and date. Time Setting: Time Setting Menu User can set the system date and time of the thermal imager in the time setting menu. After completing the date and time settings, the thermal imager will save the current settings.
  • Page 40 Reset without restoring any data. For detailed factory parameters of the thermal imager, please refer to the factory settings parameter list attached. Factory Reset Prompt ! Note: Factory Settings function will cancel all the user-defined parameters. Display the device model, device number, software version number and MAC address of the thermal imager.
  • Page 41: File Management

    4.7 File Management 4.7.1 Playback There are two playback modes: File Management Interface 1 、 File management mode: Press OK button to pop out the floating panel, select "Setting" option to activate the main menu, select File Management menu in Setting menu., and press the OK button to open the image saved in the thermal imager.
  • Page 42 Preview Mode Interface 2、 Preview mode: press OK button to pop out the floating panel and select "preview" option to enter the preview mode. Through left and right buttons to switch options, select and press the OK button to enter playback. Press "C" button to quit the image opened and return to the temperature measurement status.
  • Page 43: Deletion

    Image Playback Interface In the image playback interface, select the button on the play status bar by left and right buttons, press "OK" button to take effect, and press up and down buttons to display and hide the play status bar (press "up" button to display and "down" button to hide) Icon buttons from left to right are: previous (section), next (section), audio recording, audio playback, text playback.
  • Page 44: Technical Specifications

    ! Caution: before deleting, make sure the file is no longer needed or has been backed up, and the deleted image will not be restored. 5 Technical Specifications Technical Parameters Item BC2036-PTC Type Uncooled focal plane micro-heat type Pixel 160×120 384×288 25μm...
  • Page 45 Background temperature Automatic correction Atmospheric Automatic, subject to the input distance, ambient humidity and transmittance ambient temperature correction Date / time, temperature in ℃ / ℉/ K, language, contrast / Setup function brightness, LCD backlight, IP address Memory Card 8GB Micro TF card, max. supportability 32GB Manual / automatic saving;...
  • Page 46: In Vivo & Shell Temperature Conversion Table

    6 In Vivo & Shell Temperature Conversion Table In Vivo & Shell Temperature Conversion Table Temperature 10 14 15 16 18 19 20.320.8 21 21.621.822.422.923.5 24 25 26 27 28 29 30 Environment Temperature 7 Common Failure Countermeasures In case of any problem during utilization of the thermal imager, please adopt the table below for maintenance.
  • Page 47 In frozen image status → Press quit button to return to the real-time temperature measurement status. The thermal image is turned into Black and white color code is selected. → Select the normal color code. black and white status BC2036-PTC User Manual...

Table of Contents