  • Page 1 ™ MKII SERIES Counters Model 200C User Guide 
...
  • Page 2: Table Of Contents

    Contents Specification ..........3 General description .
  • Page 3: Specification

    Specification Display 4 decade 7-segment high brightness red LED, 14mm high Decimal point Programmable via display board Scaling Programmable via display board, retained in non-volatile memory. Signal inputs Standard (Count Up and Count Down) Standard sensitivity 180mV to 10V- protected to 100V Frequency Mode 0—100kHz maximum Impedance...
  • Page 4: General Description

    General description 200C series™ Counters are 4-decade seven segment high brightness red LED display MKII instruments based on the industry standard Intel 80C51 series microprocessor. They are built into half DIN (96 mm x 48 mm) panel mounting housings and can be supplied to operate on 115V or 230V AC or 24V DC power supplies (see Transformer connections on page 4).
  • Page 5: Safety Information For Eu Users

    Safety Information for EU Users WARNING This instrument must be earthed when powered from a mains supply (see also Mains Earth on page 6). Refer to the rating label for the pre-set voltage and ensure that the instrument voltage corresponds to the intended supply voltage. Important: The wires in the power lead fitted to mains instruments are coloured in accordance with the following code: Green...
  • Page 6: Switches And Connections

    Switches and connections ™ instruments are available only with hidden function switches that are not accessible MKII SERIES until the bezel and front panel are temporarily removed. The programming instructions in this User Guide assume that the front panel has been removed to gain access to these switches – see Fig 1 on opposite page.
  • Page 7: Rear Panel Terminals

    Rear panel terminals +10V DC (unregulated) @ 80mA Not used on standard counter Not used on standard counter Common Count Up Count Down Common Reset (the display and stored count) Stop (the count) 200C- _hb v3.1 01/2020 MKII...
  • Page 8: Programming The Instrument

    Programming the instrument Calculating a Scaling Factor The scaling factor in the ™ Counter is straightforward to calculate. For example, if for MKII SERIES each fifteen (15) pulses received you want the display to increment once, the scaling factor should be set to fifteen (15).
  • Page 9: On An Instrument That Has Been Previously Scaled

    To enter the scaling factor, simply press Switch B to alter the value for the decade that is blinking until the correct figure is displayed. To move to the next highest decade in turn just press Switch A to move from right to left. If it is necessary to enter a decimal point in the scaling factor you must use Switch A to step to the most significant decade (even if the value for the higher decades is to remain at zero) and then press Switch A once again to move on to the decimal point setting function.
  • Page 10: Operation

    Operation Counting Once a scaling factor has been set and the unit is in RUN mode the display will increment each time the requisite number of pulses are received (either up or down dependent upon which input receives the signal). The count can be reset to zero at any time by momentarily connecting the reset (RS) input on the back panel to 0V (see Fig 2...
  • Page 11: Diagrams

    Diagrams Fig.1 Front Panel Layout To access Switch A and Switch B remove the bezel and front panel Fig. 2 Rear panel layout Sensitivity Control 200C- _hb v3.1 01/2020 ! 1 1 MKII...
  • Page 12: Connection Diagrams - Typical Applications

    Connection diagrams – typical applications Single-input operation 10V A2 A1 0V M2 M1 Magnetic Pick-up Gear wheel Sens flowmeter screen Black Dual-input operation M2 M1 10V A2 A1 0V Magnetic Pick-ups Sens screens Black Gear wheels or flowmeters 200C- _hb v3.1 01/2020 ! 1 2 MKII...
  • Page 13: Additional Information

    Additional Information Electromagnetic Precautions Logitech have designed in a great deal of noise immunity into the product in accordance with EN5001-2 and EN5002-2 (radiated emissions, conducted emissions, ESD, radiated susceptibility and fast burst transient testing) However it is still vital to use good EMC (Electromagnetic Compatibility) techniques on installation of both this and other associated electronic equipment and sensors in order to ensure reliable operation.
  • Page 14: Low Voltage Directive

    Counters carry a two year warranty that is only valid where there is no damage MKII SERIES caused by accident, negligence, misapplication, or repairs/modifications attempted by unauthorised personnel. The warranty only extends to the original user. Copyright © Logitech Electronics Limited 1994 to 2017 Document No: 200C- _hb v3.0 August 2017...

This manual is also suitable for:

200c