MODEL: SE90TL
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent
power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within
walls or ceilings or into attics, crawl spaces, or garages
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control
Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noi-
ses, replace the motor with the exact service motor. The impeller should also be replaced.
OPERATION
The fan, light, and night light can be operated separately. Use a 3-function wall control. See "Connect Wiring" for details.
PLAN THE INSTALLATION
1. Do not use in a cooking area.
2. Two ways to connect ductwork to a factory-shipped unit.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
SE110L
VENTILATION FAN
INSULATION*
(Place around and
over Fan Housing.)
FAN
POWER
HOUSING
CABLE*
Seal gaps
around
Housing.
ROUND
DUCT*
Seal duct
*
Purchase
joints with
ROUND
ELBOW(S) *
separately
tape.
ROOF CAP*
(with built-in
damper)
Keep duct
runs short
WALL CAP*
(with built-in
damper)

Advertisement

loading

Summary of Contents for KAZE APPLIANCE SE90TL

  • Page 1 VENTILATION FAN MODEL: SE90TL SE110L WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • Page 2 TYPES OF TYPICAL INSTALLATIONS 1. Housing mounted to I-joists (Start at “ASSEMBLY INSTRUCTIONS 1”) 2. Housing mounted to joists (Start at “ASSEMBLY INSTRUCTIONS 1” ) 3. Housing mounted to truss (Start at step “ASSEMBLY INSTRUCTIONS 2”) ASSEMBLY INSTRUCTIONS 1. MOUNT HOUSING TO JOIST OR I-JOIST. Hold the housing so that it is in contact with the bottom of the joist.
  • Page 3 ASSEMBLY INSTRUCTIONS 4. INSTALL ROUND DUCTWORK Connect the round ductwork (not included) to the damper/duct connector, and run the ductwork to a roof or wall cap (not included). Using tape (not included), secure all the ductwork connections so that they are air tight. CONNECT ELECTRICAL WIRING Run 120 V AC house wiring to the location of the fan.
  • Page 4 SERVICE PARTS PART PART NAME Qty. Lens Grille Assembly (includes part 3) Grille Spring Motor Plate Motor Blower Wheel Wire Panel / Harness Assembly Wiring plate Housing Hanger Bar Kit Damper / Duct Connector Nut, Hex Lock Washer Screw Isolator Screw * Blower Assembly includes part 6, 5, d, 4, c, b, a.