Do you have a question about the Lean-To Tutbury Series and is the answer not in the manual?
Questions and answers
Summary of Contents for CASTLE GREENHOUSES Lean-To Tutbury Series
Page 1
R A N G E A (mm) B (mm) C (mm) D (mm) 4’4” x 4’4” 1348 CONTACT INFORMATION 4’4” x 6’4” 1968 WEBSITE: www.castlegreenhouses.co.uk 2122 1772 EMAIL: info@castlegreenhouses.co.uk 2588 4’4” x 8’5” 1320 Inc base Inc base TELEPHONE: 01782 385408 4’4”...
Thank you for purchasing your new Castle greenhouse. We recommend you familiarise yourself with the instructions and read all safety infor- mation before you commence assembly. This instruction manual is also available online at www.castlegreenhouses.co.uk in our technical help section should you need to reprint it. Should you require any additional advice you can always call us on 01782 385408. These instructions are divided into sections;...
Page 3
A (mm) B (mm) C (mm) D (mm) 4’3” x 4’4” 1295 4’3” x 6’4” 1910 2122 1772 4’3” x 8’5” 1285 2530 base base 4’3” x 10’5” 3150 3770 4’3” x 12’6” OPTION 1: base on slabs OPTION 2: base on concrete...
Page 6
Part No Quantity 1240 1240 1670 4’ 1745 Part No Quantity 1860 1860 1670 6’ 1745 Part No Quantity 2480 2480 1670 8’ 1745 Part No Quantity 3100 3100 1670 10’ 1745 Part No Quantity 3720 3720 1670 12’ 1745...
Page 7
PLEASE NOTE THAT 10mm BOLTS ARE USED THROUGHOUT THE MAJORITY OF CONSTRUCTION UNLESS STATED OTHERWISE! E.g. 15mm etc... 10mm 15mm...
Page 8
10mm 20 DOOR ON LEFT Part No Quantity DOOR ON RIGHT Part No mm Quantity EXTERNAL VIEW EXTERNAL VIEW 15mm 8 1670 1670 1279 1279 1813 1813 1957 1957 PARTS IN EPSILON DOOR BOX PARTS IN EPSILON PARTS IN EPSILON DOOR BOX DOOR BOX INTERNAL VIEW...
Page 10
M6 19 REAR GABLE Part No Quantity Part No mm Quantity REAR GABLE DOOR ON LEFT DOOR ON RIGHT EXTERNAL VIEW EXTERNAL VIEW M6 19 1670 1670 1279 1279 1813 1813 1957 1957 1252 1252 INTERNAL VIEW INTERNAL VIEW...
Page 13
Packed with base! M6 CROP 615 / 15mm 18mm If you have a metal base and you live in a windy location then you should drill and fix the frame to the base using 10mm nuts and bolts. Drill centrally between two vertical glazing bars for neatness (it is not essential to drill every section).
Page 15
Part Quantity 4x4 4x6 4x8 4x10 4x12 PLEASE NOTE THAT THE BASE SECTIONS DO NOT GO RIGHT UP TO THE WALL. THERE IS AN IN- TENTIONAL GAP WHICH ALLOWS FOR WALL VARIATIONS AND FOR AN ELECTRICTY SUPPLY TO BE INSERTED THROUGH! EQUAL No 10 x 2”...
Page 16
Part Quantity 4x4 4x6 4x8 4x10 4x12 1279 Part Quantity 4x4 4x6 4x8 4x10 4x12...
Page 17
Part Quantity 4x4 4x6 4x8 4x10 4x12 crop M4 X 4 85 / 93...
Page 22
Part No Quantity INSERT START GLASS 1730 SYBOLM6X11 SYNUTM6 563 x 805 2 OF FINISH...
Page 23
DRILL 2 X 7mm HOLES IN THE ’630’ OF YOUR CHOICE 75mm APART AVOIDING GLASS!
Page 24
THIN FOAM 4LT Glazing tips: The foam goes laterally all over the frame as per the examples in the diagram includ- ing the roof corner bars. It never goes horizontally, the glass just sits directly onto the aluminium cills in the sides. ...
Page 25
Size (mm) 4’ 6’ 8’ 10’ 12’ 610 X 610 610 X 457 C 610 X 1210 610 X 1298 610 X 700 563 X 805 610mm 10 11 OPTIONAL LOUVRE MAXIMUMS ON SIDE ONLY Size (mm) 4’ 6’ 8’ 10’ 12’ 610 x 759 573 x 100...
Page 26
Size (mm) 4’ 6’ 8’ 10’ 12’ 610 X 610 12 15 18 21 610 X 457 11 13 610 X 250 563 X 805 OPTIONAL LOUVRE MAXIMUMS ON SIDE ONLY Size (mm) 4’ 6’ 8’ 10’ 12’ 610 x 153 573 x 100...
Page 28
Part No Quantity 1320 SYBOLM6X11 SYNUTM6 10mm Part No Quantity 1320 PUSH...
Page 29
INSERT DOOR Part No Quantity SYNUTM6 Part No Quantity SYBOLM6X11 SYNUTM6 267 / DRILL 7mm HOLE AVOIDING GLASS NOT SUPPLIED.
Page 30
Part No Quantity O7mm 02 -1825 NARROW HEAD SYSCR2 SYRAWL SYBOLM6X11CROP SYNUTM6 SYSCR2 SYRAWL SYSCR2 02 -1825 NARROW HEAD SYRAWL SYRAWL 615 /...
Need help?
Do you have a question about the Lean-To Tutbury Series and is the answer not in the manual?
Questions and answers