GSS PROFESSIONAL PAVP 4300 Assembly Instructions Manual

Audio/video pal

Advertisement

Quick Links

GSS
Grundig SAT Systems GmbH
Beuthener Strasse 43
D-90471 Nuremberg
Audio/Video PAL
PAVP 4300
CLASS
Phone:
+49 (0) 911 / 703 8877
Fax:
+49 (0) 911 / 703 9210
E-mail:
info@gss.de
Internet:
http://www.gss.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFESSIONAL PAVP 4300 and is the answer not in the manual?

Questions and answers

Summary of Contents for GSS PROFESSIONAL PAVP 4300

  • Page 1 Audio/Video PAL PAVP 4300 CLASS Phone: +49 (0) 911 / 703 8877 Fax: +49 (0) 911 / 703 9210 Grundig SAT Systems GmbH E-mail: info@gss.de Beuthener Strasse 43 Internet: http://www.gss.de D-90471 Nuremberg...
  • Page 2: Table Of Contents

    o n t e n t s 1 Safety regulations and notes ................3 2 General information ..................4 Scope of delivery ................4 Meaning of the symbols used ............... 4 Technical specifications ............... 4 Description ..................5 Display of the control unit software version ..........5 3 Installation ......................
  • Page 3: Safety Regulations And Notes

    • Test the software versions of the head-end station and the cassette and update them if necessary. The current software versions can be found at "www.gss.de". Take action to prevent static discharge when working on the device! Electronic devices should never be disposed of in the household rubbish. In...
  • Page 4: General Information

    e n e r a l i n f o r m a t i o n C o p e o f d e l i v e ry 1 PAVP 4300 cassette 1 Brief assembly instructions 1 Measuring log e a n i n g o f t h e s ym b o l s u s e d Important note —>...
  • Page 5: Description

    "V 44" or higher. You can find the current op- erating software for the control unit and the cassette, the software "BE-Flash" and the current assembly instructions on the website "www.gss.de". The cassette is designed for use in head-end stations of the profi line.
  • Page 6: Installation

    n s t a l l a t i o n n s ta l l i n g t h e C a s s e t t e – Ensure the head-end station is mounted so it will not be able to vibrate. Avoid, for example, mounting the head-end station onto a lift shaft or any other wall or floor construction that vibrates in a similar way.
  • Page 7: Emc Regulations

    r e g u l at i o n s To comply with the current EMC regulations, it is necessary to connect the lines leading in and out of the head-end station using cable terminals. When mounting the cassette in a head-end station which is installed in a 19" cabinet, make sure the connections leading in and out for the 19"...
  • Page 8: Overview Of The Cassette

    "RS 232" using a PC or notebook and the software "BE-Flash". You can find the current operating software on the website "www.gss.de". o n n e C t i n g t h e C a s s e t t e • Connect the peripheral devices to the cinch input sockets...
  • Page 9: The Control Unit At A Glance

    h e C o n t r o l u n i t a t a g l a n C e e n u i t e m s Program the cassette using the buttons on the control unit of the head-end sta- tion.
  • Page 10: Programming

    r o g r a m m i n g r e pa r at i o n • Connect the test receiver to the HF output or the test output of the head-end station. • Set the output channels / output frequencies of the cassette (page 16) and 16) and ) and adjust the test receiver to the respective channel / frequency. • Switch on the modulator if necessary (page 14).
  • Page 11: Programming Procedure

    ro g r a m m i n g pro C e d u r e Ein / On BE–Remote V 44 please wait … t > 10 s Bx 1A TWIN-SAT Böx 4 TWIN-SAT Box 1 Box 2 ....C5-12,S3-24 C5-12,S3-24 –...
  • Page 12: Programming The Cassette

    r o g r a m m i n g t h e C a s s e t t e —> Pressing the button for longer than 2 seconds cancels the programming procedure. This takes you back to the program item "Selecting the cassette"...
  • Page 13: Selecting The Channel Strip

    —> The "Selecting the channel strip" – "Bx 1A" menu is activated. e l e C t i n g t h e C h a n n e l s t r i p Bx 1A • Use to select the channel strip (modulator) "A", "B" or "C" to be set. —>...
  • Page 14: Hf Output Level

    o u t p u t l e v e l In this menu you can set the HF output levels of the channel strips "A", "B" and "C" to the same values and switch on or off the modulator of the channel strip. Bx 1A MODULATOR Level...
  • Page 15: Channel / Frequency Setting

    • Press the button. —> The "Channel / frequency setting" / "TV standard of the output signal" – "NORM" menu is activated. h a n n e l f r e q u e n C y s e t t i n g In this menu, you can select the channel or frequen c y setting for the adjustment of the HF output. The channel setting covers the range of channels C02 …...
  • Page 16: Output Channel

    u t p u t C h a n n e l Bx 1A OUTPUT Bx 1A OUTPUT ▶ Fine ▶ • Use to set the output channel of the modulator. i n e t u n i n g Adjust the fine tuning (frequency offset) only in individual cases which give you reason to do so (e. g. moiré, interferences), since all TV sets connected to the cable system have to be fine tuned after making changes.
  • Page 17: Audio Type

    u d i o t y p e In this menu you can set the audio type in which the modulator is to modulate the audio signals. If a mono audio signal (white Cinch socket) is fed in into a channel strip, program the respective channel strip to "Mono L".
  • Page 18: Final Procedures

    i n a l pro C e d u res After installing the head-end station, upgrading accessories or installing cas- settes it is necessary to tighten all cable connections, cable terminals and cover screws in order to maintain compliance with current EMC regulations securely. • Securely tighten the cable connections using an appropriate open-ended spanner.
  • Page 19: Channel And Frequency Tables

    h a n n e l a n d f r e q u e n C y t a b l e s CCIR – Band I/III (Frequency raster 7 MHz) 48.25 133.25 175.25 C 11 217.25 S 15 259.25 55.25 140.25...
  • Page 20 Declaration of CE conformity - 20 - PAVP 4300...
  • Page 21 Service: Phone: +49 (0) 911 / 703 2221 Fax: +49 (0) 911 / 703 2326 Email: service@gss.de Alterations reserved. Technical data E. & O.E. © by GSS GmbH V2/11032011...

This manual is also suitable for:

Pavp 4300

Table of Contents