Page 1
Mobile Panel 7200 User's manual Version: 1.01 (April 2020) Order no.: MAMP7200-ENG Translation of the original documentation All values in this manual are current as of its creation. We reserve the right to change the contents of this manual without notice. B&R Industrial Automation GmbH is not liable for technical or editorial errors and defects in this manual.
3.5 Installing the handle and hand strap......................41 3.6 Operating the Mobile Panel.......................... 43 3.6.1 Touch screen calibration..........................43 3.6.1.1 Windows 10 IoT Enterprise 2016 LTSB.................... 43 3.7 Key and LED configuration...........................44 3.8 Using the USB interface..........................45 Mobile Panel 7200 User's manual V 1.01...
Page 3
7.1.1.4 Temperature/Humidity diagram......................60 7.1.2 5MMUSB.032G-02...........................61 7.1.2.1 General information..........................61 7.1.2.2 Order data............................61 7.1.2.3 Technical data............................61 7.1.2.4 Temperature/Humidity diagram......................62 7.2 Wall mounts..............................63 7.2.1 5ACCWB70.0000-000..........................63 7.2.1.1 General information..........................63 7.2.1.2 Order data............................63 7.2.1.3 Technical data............................63 Mobile Panel 7200 User's manual V 1.01...
Page 4
7.4.1.4 Cable pinout............................72 8 Maintenance......................73 8.1 Cleaning................................ 73 8.2 Repairs/Complaints and replacement parts....................73 Appendix A Stop button....................74 Appendix B Enabling control device............... 75 Appendix C Chemical resistance................76 Appendix D Viewing angles..................77 13 Abbreviations......................78 Mobile Panel 7200 User's manual V 1.01...
General information 1 General information 1.1 Manual history Version Date Change 1.00 March 2020 First version. • 1.01 April 2020 Updated section "Software" on page Mobile Panel 7200 User's manual V 1.01...
LS251 or similar product), the safety measures that apply to industrial controllers (protection by protective equip- ment such as emergency stops) must be observed in accordance with applicable national and international regu- lations. This also applies to all other connected devices, such as drives. Mobile Panel 7200 User's manual V 1.01...
Internet poses a potential threat to the system. It is the direct responsibility of the user to avert these dangers and to take appropriate measures such as virus protection programs and firewalls to protect against them and to use only software from trustworthy sources. Mobile Panel 7200 User's manual V 1.01...
The term "control systems" refers to all types of B&R products such as controllers (e.g. X20), HMI systems (e.g. Power Panel T30), process control systems (e.g. APROL) and supporting systems such as engineering workstations with Automation Studio. Mobile Panel 7200 User's manual V 1.01...
Up to 6 mm ±0.1 mm Over 6 to 30 mm ±0.2 mm Over 30 to 120 mm ±0.3 mm Over 120 to 400 mm ±0.5 mm Over 400 to 1000 mm ±0.8 mm Mobile Panel 7200 User's manual V 1.01...
A color display ensures that all tasks can be managed visually, while the touch screen ensures an intuitive user interface. 2.1.1 Ergonomics • Functional multigrip • Rounded housing • Desktop operation • Wall mount operation • Easy-to-read display Mobile Panel 7200 User's manual V 1.01...
Technical data 2.1.2 Configuration The following components are mandatory for a functional Mobile Panel 7200: • Operator panel • Attachment cables MP7200 configuration Operator panels 5MP7251.101P-000 Cables Select 1 each Control cabinet cables 5CAMPC.0020-10 5CAMPC.0020-11 Attachment cables 5CAMPH.0018-40 5CAMPH.0050-40 5CAMPH.0100-40 5CAMPH.0150-40...
TCP/IP A transfer rate of 100 Mbit/s is only possible with a suitable attachment cable. Switching takes place automatically. Information: Necessary drivers must be downloaded from the B&R website, not from manufacturer websites. Mobile Panel 7200 User's manual V 1.01...
Full speed (12 Mbit/s) High speed (480 Mbit/s) Current-carrying capacity Max. 0.5 A Cable length USB 2.0 Max. 5 m The USB interface is protected by a maintenance-free "USB current-limiting switch" (max. 0.5 A). Mobile Panel 7200 User's manual V 1.01...
This color printout is not a true color printout, i.e. the colors of the panel overlay may vary slightly. 2.2.2.2.1 Keys and LEDs Information: The MP7251 does not support fast blinking; the ADI library handles fast blinking the same as slow blinking. Mobile Panel 7200 User's manual V 1.01...
Page 16
Speed + Page up LEDs Description Cannot change usage Power: The device is supplied. Power Possible use Factory configuration Run: Application in operation Error Error: Error in application Feedback for startup 2nd level enabled Mobile Panel 7200 User's manual V 1.01...
The key switch has 3 positions, each of which clicks into place. The key can be re- moved in any of these 3 switch positions. 2 identical keys are included in the content of delivery. Rotation angle of the key switch Mobile Panel 7200 User's manual V 1.01...
Enable position Release ↓ Actuates the enable device ↑ Releases the enable device Switch positions Switch position 1 of the enable device (zero position) Switch position 2 of the enable device (enable position) Mobile Panel 7200 User's manual V 1.01...
Page 19
The following connection example shows how an enable function up to category 4 PL e can be achieved with the MP7200 enabling control device. It is important to note that the entire concept of the machine must be designed for this. Mobile Panel 7200 User's manual V 1.01...
Page 20
The Mobile Panel, safety controller and all subsequent components must be taken into account when calculating the entire "approval via enabling control device" safety function. Mobile Panel 7200 User's manual V 1.01...
Page 21
A second, deliberate start command is required for this (e.g. actuating a specific key on the handheld control device). • The only person permitted in the danger zone is the person actuating the enabling control de- vice. Mobile Panel 7200 User's manual V 1.01...
A handle (1) can be installed on the MP7200 with or without a hand strap (2). The handle is secured with 3 screws (Torx, size 10). The hand strap can only be used if the handle is installed. Mobile Panel 7200 User's manual V 1.01...
Figure Operating units 5MP7251.101P-000 Mobile Panel 7200 10.1" WXGA TFT - 800 x 1280 pixels - Mul- ti-touch (projected capacitive) - Intel Celeron N2807 processor 2*1.58 GHz - 4 GB RAM - For Windows W10 2016 - 1x Ethernet 10/100, 1x USB 2.0 - 1x key switch - 1x stop button - 1x enable...
Page 24
5 to 95%, non-condensing Transport 5 to 95%, non-condensing Vibration Operation 5 to 8.4 Hz: 3.5 mm amplitude 8.4 to 150 Hz: 1g Shock Operation 15 g, 11 ms Table 2: 5MP7251.101P-000 - Technical data Mobile Panel 7200 User's manual V 1.01...
Page 25
Connection via Mobile Panel cable. Connected via attachment cable 5CAMPH.0xxx-40. EN 60950 requirements must be observed. At least IP54 after 2 falls from 1 m height. With stop button and key switch (without key). Mobile Panel 7200 User's manual V 1.01...
Mobile Panel connection box - For cables with push-pull circular connectors 4MPCBX.0001-00 Mobile Panel small connection box - For cables with push-pull circular connectors Table 3: 5CAMPH.0018-40, 5CAMPH.0050-40, 5CAMPH.0100-40, 5CAMPH.0150-40, 5CAMPH.0200-40 - Order data EN 60950 requirements must be observed. Mobile Panel 7200 User's manual V 1.01...
Page 27
20 m ±0.15 m Diameter 7 mm Bend radius Min. 60 mm Weight 153 g/m Tension Max. 140 N Table 4: 5CAMPH.0018-40, 5CAMPH.0050-40, 5CAMPH.0100-40, 5CAMPH.0150-40, 5CAMPH.0200-40 - Technical data EN 60950 requirements must be observed. Mobile Panel 7200 User's manual V 1.01...
≤30 Ω/km Material Tinned copper stranded wire Permissible operating voltage 30 VDC Outer jacket Material Silicone- and halogen-free, flame-retardant PUR outer jacket Color Similar to RAL 7012 Table 6: 5CAMPC.0020-10 - Technical data Mobile Panel 7200 User's manual V 1.01...
Page 30
Dimensions Length 2 m ±0.05 m Diameter 10 mm Bend radius Min. 60 mm Weight 153 g/m Tension Max. 140 N Table 6: 5CAMPC.0020-10 - Technical data EN 60950 requirements must be observed. Mobile Panel 7200 User's manual V 1.01...
Page 31
Yellow Pin 6 (RX) Blue Pin 2 (TX) Shielding Shielding Shielding Information: When installing the control cabinet cable, make sure that it is not too loose or too tight in the control cabinet. Mobile Panel 7200 User's manual V 1.01...
Page 32
2.3.2.2.1.5 Receptacle - Drilling template A cutout or drill hole must be made (e.g. in a control cabinet door) according to the following diagram to fasten the receptacle. Legend Cutout (hatched) Outline of locknut Marking point 28.6 Mobile Panel 7200 User's manual V 1.01...
Page 33
Enable switch Direct connection between enable switch and monitoring device (6 wires) (2 wires not used on the MP40/50 and MP7x00) Connector Type Receptacle for push-pull locking mechanism Table 8: 5CAMPC.0020-11 - Technical data Mobile Panel 7200 User's manual V 1.01...
Page 34
Dimensions Length 2 m ±0.05 m Diameter 10 mm Bend radius Min. 60 mm Weight 153 g/m Tension Max. 140 N Table 8: 5CAMPC.0020-11 - Technical data EN 60950 requirements must be observed. Mobile Panel 7200 User's manual V 1.01...
Page 35
Yellow Pin 2 (TX) Blue Pin 6 (RX) Shielding Shielding Shielding Information: When installing the control cabinet cable, make sure that it is not too loose or too tight in the control cabinet. Mobile Panel 7200 User's manual V 1.01...
Page 36
2.3.2.2.2.5 Receptacle - Drilling template A cutout or drill hole must be made (e.g. in a control cabinet door) according to the following diagram to fasten the receptacle. Legend Cutout (hatched) Outline of locknut Marking point 28.6 Mobile Panel 7200 User's manual V 1.01...
It is the machine manufacturer's responsibility to select a handheld terminal suitable for the machine and to con- figure any additional add-on options in accordance with the legally required danger and risk assessment. Mobile Panel 7200 User's manual V 1.01...
Ethernet connection - Communication interface Multipoint connector - Main connection for power supply and control lines 3.3 Cable installation This section describes all the necessary procedures for installing a attachment cable for the Mobile Panel 7200 (see "Attachment cables" on page 26 for available cables).
• All screws on the device must be installed and tightened. Otherwise, the device cannot be completely sealed. This must also be observed when the unit is not in operation or during storage and transport. Mobile Panel 7200 User's manual V 1.01...
• All screws on the device must be installed and tightened. Otherwise, the device cannot be completely sealed. This must also be observed when the unit is not in operation or during storage and transport. Mobile Panel 7200 User's manual V 1.01...
6. Attaching the upholstery (optional). The hook-and-loop fastener must be facing upwards (1). 7. Tighten the handle with a screwdriver (torque: 0.8 - 1.0 Nm) at the top of the handheld control device. Mobile Panel 7200 User's manual V 1.01...
Page 42
9. Pull the hand strap belt through until a tight but comfortable hold is achieved. 10.Close the hook-and-loop fasteners. ✓ The handle and hand strap are now completely installed and ready for use. Mobile Panel 7200 User's manual V 1.01...
Microsoft multi-touch drivers are installed on the device during installation of Windows 10 IoT Enterprise 2016 LTSB. After successful installation of Windows 10 IoT Enterprise 2016 LTSB, the device is immediately ready for operation. Mobile Panel 7200 User's manual V 1.01...
When using keyboard shortcuts with 3 or more keys, key ghosting may occur due to the key hardware. Only the functionality of keyboard shortcuts with 2 keys is guaranteed. https://en.wikipedia.org/wiki/Rollover_(key) (as of 2020-02-10) Mobile Panel 7200 User's manual V 1.01...
1. Complete all processes that access the USB device. 2. Disconnect the USB device from the USB interface. 3. Press the protective cover down firmly and completely. ✓ The USB device is disconnected and the degree of protection is restored. Mobile Panel 7200 User's manual V 1.01...
• Use complementary colors for subsequent images. • Use screensavers. 3.10 Pixel errors Information: Displays can contain faulty pixels (pixel errors) due to the manufacturing process. They are not grounds for initiating a complaint or warranty claim. Mobile Panel 7200 User's manual V 1.01...
Starts the boot procedure with the marked device. [Esc] Exits the boot menu and boots with the default settings. Information: The key signals of the USB keyboard are only accepted after the USB controller in initialized. Mobile Panel 7200 User's manual V 1.01...
Windows 10 IoT Enterprise 2016 LTSB must be activated like its predecessor Windows 10 IoT Enterprise 2015 LTSB. This takes place at B&R. The activation status can be checked in the Control Panel: Mobile Panel 7200 User's manual V 1.01...
Programs that use Automation Device Interface (ADI) functions must be executed with administrator rights. This also pertains to B&R programs such as the Control Center and B&R VNC Viewer (when using the RFB extension). Mobile Panel 7200 User's manual V 1.01...
4.3 Automation Device Interface (ADI) The Automation Device Interface (ADI) enables access to specific functions of B&R devices. Information: On the MP7200, administrator rights are required to access ADI functions. Mobile Panel 7200 User's manual V 1.01...
The set display brightness (e.g. via the B&R Control Center or ADI library) is only effective until the system is restarted. The display brightness can be permanently adjusted in the operating system under Start / Settings / System / Display / Adjust brightness level. Mobile Panel 7200 User's manual V 1.01...
For a detailed description of how to use ADI functions, see Automation Help. The B&R ADI Development Kit can be downloaded at no cost from the Downloads section of the B&R website (www.br-automation.com). Mobile Panel 7200 User's manual V 1.01...
4.3.3.1 Characteristics, limitations For some methods (e.g. AdiGetDisplayBrightness and AdiSetDisplayBrightness), the first method call may fail and a corresponding error code returned. A new call of the method is then executed without errors. Mobile Panel 7200 User's manual V 1.01...
The following example shows how a ScanCodeMapping entry is structured. ScanCodeMapping Schematic diagram of an entry KEY_xxx=SC,SC,MF1,MF1,MF2,MF2,MF3,MF3 Scan code set 1 is used for the configuration. For a current listing, see "Key codes" on page Mobile Panel 7200 User's manual V 1.01...
UL testing of industrial control equipment UL/IEC 61010-2-201 Requirements for control equipment, including programmable logic controllers (PLCs) and applicable requirements from UL/IEC 61010-1 UL approval for robotics applications UL 1740 Industrial Robots and Robotic Equipment E216950 (TETZ2, TETZ8) Mobile Panel 7200 User's manual V 1.01...
General information Capacity 2 GB 4 GB LEDs 1 LED (green) MTBF >3,000,000 hours Type USB 1.1, USB 2.0 Servicing None Default file system FAT32 Certifications Table 13: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Mobile Panel 7200 User's manual V 1.01...
Page 59
8.35 mm Table 13: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Signals data transfer (reception and transmission). The maximum ambient temperature is typically derated 1°C per 1000 meters starting at 500 m above sea level. Mobile Panel 7200 User's manual V 1.01...
Accessories 7.1.1.4 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C Storage and transport RH [%] Relative humidity (RH) in percent and non-condensing Mobile Panel 7200 User's manual V 1.01...
Max. 67 mA in sleep mode, max. 122 mA read, max. 141 mA write Ambient conditions Temperature Operation 0 to 70°C Storage -55 to 95°C Transport -55 to 95°C Table 15: 5MMUSB.032G-02 - Technical data Mobile Panel 7200 User's manual V 1.01...
The maximum ambient temperature is typically derated 1°C per 1000 meters starting at 500 m above sea level. 7.1.2.4 Temperature/Humidity diagram RH [%] T [°C] -50 -40 -30 -20 -10 Diagram legend Operation T [°C] Temperature in °C RH [%] Relative humidity (RH) in percent and non-condensing Storage and transport Mobile Panel 7200 User's manual V 1.01...
Model number Short description Figure Accessories 5ACCWB70.0000-000 Mobile Panel 7200 wall mount - For MP7251 Table 16: 5ACCWB70.0000-000 - Order data 7.2.1.3 Technical data Information: The following specified characteristic data, features and limit values are only valid for this accessory and may differ from those of the complete system.
Mobile Panel box cable - With wire end sleeves - With connector contacts Table 18: 4MPCBX.0000-00 - Order data 7.3.1.3 Interfaces Legend Emergency stop button Hot plug button M16 screw plug Connection position (open) M20 screw plug Protective cover Mobile Panel 7200 User's manual V 1.01...
Achievable safety classifications (safety integrity level, safety category, performance level) are documented in the user's manual (section "Safety technology"). For the box cable. The protective cover must be connected if no Mobile Panel is connected. Mobile Panel 7200 User's manual V 1.01...
Screw plugs M16x1.5 (screwed on) Screw plugs M20x1.5 (screwed on) Protective cover in place (design similar to 5CAMPP.0001-10) A box cable (5CAMPB.0xxx-10) is necessary to establish the electrical connection between the control cabinet and connection box. Mobile Panel 7200 User's manual V 1.01...
Coating Powdered RAL 7012, fine structure Cover plate Material GK-AlSi9Mg (gravity die casting) Dimensions Width 90 mm Height 74.2 mm Depth 150 mm Weight Approx. 500 g Table 22: 4MPCBX.0001-00 - Technical data Mobile Panel 7200 User's manual V 1.01...
Mobile Panel box cable - With wire end sleeves - With connector contacts 5CAMPB.0100-10 Mobile Panel box cable - With wire end sleeves - With connector contacts Table 24: 5CAMPB.0050-10, 5CAMPB.0100-10 - Order data Mobile Panel 7200 User's manual V 1.01...
10 m ±20 cm Diameter 10 mm Bend radius Moving 60 mm Fixed installation 30 mm Weight 160 g/m Tension Max. 140 N Table 25: 5CAMPB.0050-10, 5CAMPB.0100-10 - Technical data EN 60950 requirements must be observed. Mobile Panel 7200 User's manual V 1.01...
Pin, wire color Pin, wire color CAN 1 High Pin 1 White CAN 1 Low Pin 2 Orange Shielding Pin 3 Black CAN 2 High Pin 4 Yellow CAN 2 Low Pin 5 Green Mobile Panel 7200 User's manual V 1.01...
Repairs are therefore only permitted to be carried out by authorized qualified personnel at the manufacturer's premises. To process a repair/complaint, a repair order or complaint must be created via the B&R Material Return Portal on the B&R website (www.br-automation.com). Mobile Panel 7200 User's manual V 1.01...
Max. 1000 mA (per contact) Utilization category DC-13 (per IEC 60947-5-1) B10d value (switching cycles) 250,000 Variant Dual-circuit, external wiring Electrical isolation 500 VAC to rest for 1 minute EN 60950 requirements must be observed. Mobile Panel 7200 User's manual V 1.01...
500 VAC to rest for 1 minute Output testing Changing grip function Output synchronization Specifications for EN ISO 13849-1:2015 Enable Category Performance level Proof test interval 20 years Specifications for EN 64508 EN 60950 requirements must be observed. Mobile Panel 7200 User's manual V 1.01...
Appendix D Appendix D Viewing angles For viewing angle specifications (R, L, U, D) of the display types, see the technical data of the individual compo- nents. 6 o'clock direction Mobile Panel 7200 User's manual V 1.01...
To be defined Used in technical data tables when there is currently no value for specific tech- nical data. The value will be supplied later. Table 26: Abbreviations used in this user's manual Mobile Panel 7200 User's manual V 1.01...
Page 79
Publishing information Mobile Panel 7200 User's manual V 1.01...
Page 80
Publishing information Publishing information B&R Industrial Automation GmbH B&R Strasse 1 5142 Eggelsberg Austria Telephone: +43 7748 6586-0 Fax: +43 7748 6586-26 office@br-automation.com Mobile Panel 7200 User's manual V 1.01...