1. Installation (1) The recommended erection height is 2.5-3 meters (2) The recommended distance to the subjects is 3 meters (3) The thermal lens must be adjusted according to the environment. (4) Avoid strong light in the installation environment. (5) Outdoor ground temperature would affected by weather, please avoid capturing the outdoor ground.
Page 5
2. Camera Setting 2-1. Initial system setting (1)Default ip of the camera is posted on the outer box (2)To search the camera, please check the ip setting of your PC. The IP address must be set to 10 network segments, and the subnet mask should be set to 255.0.0.0 (3)To get to the web interface, please enter the default ip of camera (4)Default login information:...
Page 6
2-2. IP setting To modify the IP of the camera, please go to the web interface【Admin Menu】>【Network Setup】>【Ethernet Interface】 (1)Turn off BOOTP/DHCP (2)Set up newIP address and network mask - 6 -...
2-3. Temperature Compensation To do the temperature calibration, please go to the web interface【Setup Menu】>【Image Control】>【Thermal Sensor Settings】>【Temperature Compensation】 Device has been set the temperature compensation before leaving the factory. To ensure the accuracy, please set the temperature compensation before you start to use. To calibrate the temperature, you need to set a subject with constant temperature.
Page 8
Fill in the string below &caption=$(SEN.TTR.CELSIUS)&description=$(ID.ET0), $(ID.ETHERNET) (5) Send Port - 8 -...
2-5. Alarm Sound Setting Turn on the Audio Output To set the audio input/output, please go to the web interface【Admin Menu】 >【Audio and VoIP Telephony】>【Speaker and Microphone】 Alarm Sound Setting Please go to the web interface【Admin Menu】>【Audio and VoIP Telephony】 >【Sound Profiles】...
Page 10
2-6. Temperature Alarm Event and Measurement Area Please go to the web interface【Setup Menu】>【Event Control】>【Event Overview】> 【Environment Events】 Set the minimum alarm temperature (ex:alarm when temperature reach 37.5 degree) (1) Add a new Environment Events, we named as ‘Tar’. (2) Event Dead Time Delay alarm for few seconds when event occur.
Page 11
(5) Measurement Mode and Trigger Mode (6) Set the Alarm Condition Set the minimum alarm temperature, and choose Higher than. Camera will alarm when the temperature higher than 37.5 degree. (7) Thermal Radiation Setting The are some thermal radiation parameters down below, please choose the suggested options.
Page 12
Set the maximum alarm temperature (ex:alarm when temperature lower than 40 degree) (1) Add a new Environment Events, we named as ‘Limit’ (2) Event Dead Time Delay alarm for few seconds when event occur. (3) Event Sensor Type Choose Thermal Radiometry. (4) Edit Measurement Area To set the measurement area, please click the blank setting box first.
Page 13
(5) Measurement Mode and Trigger Mode (6) Set the Alarm Condition Set the maximum alarm temperature, and choose lower than. Camera will alarm when the temperature lower than 40 (7) Thermal Radiation Setting The are some thermal radiation parameters down below, please choose the suggested options.
2-7. Alarm event setting Please go to the web interface【Setup Menu】>【Event Control】>【Event Overview】> 【Meta Events】 Press to enter the edit page. (1) Add a new event (2) Event Sensor Type (3) Logic event need to set two logic condition, please set the event ’Tar’ and ‘Limit’ we just set, and set the order of occurrence.
2-8. Alarm Output Please go to the web interface【Setup Menu】>【Event Control】>【Event Overview】> 【Action Group Overview】 (1) Edit the alarm setting (2) Action Group Here user can name a alarm, turn on the alarm, and set time table. (*Choose No time table to enable the alarm whole day.) (3) Event Selection Please choose the alarm event we have set.
(5) Actions Do the actions below when event occur. (*Commonly actions like: Visual Alarm: Red Frame, Play Sound...) 2-9. Save the Configuration Please go to the web interface【Admin Menu】->【Configuration】 After setting all the parameters and event, must save the configuration into the camera flash . Store:store current configuration to camera flash permanently.
Page 17
3. EZ Pro Setting 3-1. EZ Pro event setting 【Set camera recording】 To use the broadcast function of EZ Pro (including: sound alarm, record events, etc.), it is necessary to turn on the camera recording. (1) Right-click on the camera name, choose ‘Camera Setting’. (2) Turn on the ‘recordming’...
Page 18
(3) There will be a red point on the left side of camera icon when the camera is recording. 【Add an alarm event】 (1) New an event rule 【Main Menu】 > 【System Sdministration】 > 【Event Rules】 > 【Add new event rule】 (2) Set the event rule Press on the right side.
Page 19
(4) Interval of action An interval between events. If immediate report is required, please cancel. (5) Press save. - 19 -...
Need help?
Do you have a question about the iMage-M and is the answer not in the manual?
Questions and answers