Download Print this page

Gira DALI Tronic Trafo 105 W Operating Instructions Manual

Advertisement

Quick Links

DALI Tronic transformer 105 W
DALI Tronic transformer 105 W
Order-No. : 2380 00
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
(1) Fastening screws for terminal cover
(2) Mounting holes
(3) Terminal covers
3 Function
Intended use
-
Power supply for LV halogen lamps
-
Switching and brightness adjustment is performed with DALI control units or installation
buttons
-
Installation in false ceilings or surface mounting
Product characteristics
-
No-load proof
-
Electronic short circuit protection
-
Electronic overload protection
-
Electronic over-temperature protection
-
Suitable for emergency current installation
82575902
Figure 1
13.05.2011
1/7

Advertisement

loading

Summary of Contents for Gira DALI Tronic Trafo 105 W

  • Page 1 DALI Tronic transformer 105 W DALI Tronic transformer 105 W Order-No. : 2380 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the device and result in fire and other hazards.
  • Page 2: Operation

    DALI Tronic transformer 105 W i Flickering of the connected lamps is possible if the load is below the specified minimum. This does not represent any defect in the device. Behaviour after mains voltage failure in operation with DALI control unit The behaviour is dependent on the DALI control unit.
  • Page 3 DALI Tronic transformer 105 W All transformers switch off. Make a long press on the installation button. All transformers switch on to minimum brightness. i If the installation button is still pressed, the light becomes brighter up to maximum brightness. 5 Information for qualified electricians 5.1 Fitting and electrical connection DANGER!
  • Page 4 DALI Tronic transformer 105 W Cable recommendations for reliable strain relief Primary side Secondary side H03VV-F 2×0.50mm H03VV-F 2×0.75mm H03VV-F 2×0.75mm H05VVH2-F 2×0.75mm H03VVH2-F 2×0.75mm H05VV-F 2×1.5mm H05VVH2-F 2×0.75mm H05VV-F 2×2.5mm NYM-J 3×1.5mm NYM-J 3×1.5mm NYM-O 2×1.5mm NYM-O 2×1.5mm NYM-J 3×2.5mm Figure 3: Stripping lengths Strip connecting cables according to specifications (Figure 3).
  • Page 5 DALI Tronic transformer 105 W Connecting transformer with DALI control unit Figure 4: Connection diagram with DALI control unit Connect transformer (5) and DALI control unit (4) according to connection diagram (Figure 4). i The connected transformers and the DALI control unit may be operated on different outer conductors.
  • Page 6: Troubleshooting

    DALI Tronic transformer 105 W 5.2 Commissioning Commissioning with DALI control unit Commissioning depends on the control unit being used. The system is fitted and connected. Switch on mains voltage. Transformer switches to maximum brightness. Perform commissioning (see instructions for control unit) Commissioning with installation button The system is fitted and connected.
  • Page 7: Warranty

    The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. Gira Giersiepen GmbH & Co. KG...