Maintenance
Check interior
Check oil fence drain
Check terminal and wirings
Check engine/generator mount
Check each rubber hose
Clean the oil fence and check for rust
The above intervals of inspection and maintenance are respectively based on the operation time of 125
hours of used per month and of 1,500 hours of use per year.
Maintenance
Check engine valve clearance
Change DEF dosing unit filter
Clean DEF tank

5.3 Periodic Replacement Parts

Part number changes upon modification. For replacement of parts, make sure whether the part
number is correct or applicable.
Description
Air Filter Element
Engine Oil Filter Element (Main)
Engine Oil Filter Element (By-pass)
Fuel Pre-filter Element
Fuel Filter Element
Strainer [A] for Engine Supply Pump
Strainer [B] for Engine Supply Pump
Belt
DEF Dosing unit filter
5. Periodic Inspection
Daily
Every
1,000
hours
Outer Element [C]
Inner Element [D]
Every
Every
Every
250
500
1,000
hours
hours
hours
Every
Every
3,000
4,500
hours
hours
Part Number
32143 16000
32143 15901
ISUZU 113240-2330
ISUZU 113240-2410
43543 00900
ISUZU 898074-2881
43543 02800
ISUZU 898312-9180
ISUZU 115619-5090
ISUZU 115619-5070
ISUZU 113671-5030
ISUZU 898169-4030
5-3
Ref.
Remarks
3-13
3-15
5-13
Every 4 months
5-14
Every 1 year
5-15
Every 1 year
5-15
Every 1 year
Ref.
Remarks
5-15
Clean as required.
Q'ty
1
1
1
1
2
2
1
2
1
1