RM5000EX Operations Manual Table of Contents INTRODUCTION.........................5 FEATURES..........................6 STANDARD FEATURES......................6 SYSTEM FEATURES......................6 INDIVIDUAL FEATURES.......................6 NUMBER PLAN........................7 FEATURE DESCRIPTION......................8 HANDSET / LOUDSPEAKING....................8 COFIDENTIAL /SOFTSPEAKING..................8 SIMPLEX..........................8 MICROPHONE CUTOFF.......................8 DIRECT DIALING........................8 DIRECT ACCESS........................8 ALARM............................9 LINE SUPERVISION......................9 TWO BUTTON DC SHIFT SUB-STATION................9 REMOTE CONTROL......................9 CAMP ON BUSY EXTENSION....................9...
Page 4
ALL CALL........................29 GROUP CALL......................29 GROUP CONFERENCE.....................32 HANDSETS......................32 FIREALARM......................33 TELEPHONE LINE INERFACE..................34 INSTALLATION.......................36 POWER HOOKUP......................36 PROGRAM DISTRIBUTION..................36 CRISIS ALERT NETWORK..................36 SWITCH PROGRAMMING..................37 RESET BATTERY RAM....................37 TWO STAGE EX500......................42...
September 2018 Operations Manual RM5000EX INTRODUCTION The EX500 exchange processor is a Crisis Alert Central Exchange. One EX500 with one, two or three LC500 subscriber cards are mounted in the first RK500 card rack for a capacity of 24 intercom stations.
RM5000EX Operations Manual September 2018 FEATURES STANDARD FEATURES 3 Links Hands free Loudspeaking Confidential Softspeaking T-Button for manual control of speech direction Microphone mute Date transmission for remote control Privacy Camp on busy extension Crisis Alert Network Interface SYSTEM FEATURES...
September 2018 Operations Manual RM5000EX NUMBER PLAN IDLE: 10-65 Subscriber number 2 digit dial 100-155 Subscriber number 3 digit dial 1000-1055 Subscriber number 4 digit dial All Call 71-79 Group Calls Respond to meet-me Log in activated by direct dial 3...
RM5000EX Operations Manual September 2018 FEATURE DESCRIPTION HANDSET / LOUDSPEAKING When two intercom stations are connected, either party may speak to the other hands free without touching any buttons. COFIDENTIAL /SOFTSPEAKING At any time during the call, either one or both parties may pick up their station AA918 and use it as a handset for a confidential conversation.
September 2018 Operations Manual RM5000EX ALARM Long DC shift (1sec<) will send ALARM to the call number programmed for direct access. LINE SUPERVISION Line Supervision is activated with privilege #10. The audio lines from the intercom is monitored for shorts, open, powerfail and will send FAULT to the call number programmed for Direct Access.
RM5000EX Operations Manual September 2018 PRIORITY When a station is programmed with the privilege “Priority” it may connect to a busy or privacy station by dialing “0” . This is only possible if the busy station does not have Priority privilege PERSONAL QUEUE Each intercom station has a Personal Queue.
September 2018 Operations Manual RM5000EX PAGING Allows for one way paging from one station to other stations in the exchange and will override calls in progress (they will reconnect when the Page is completed).There are 15 paging groups in the system.
September 2018 TWO WAY RADIO The RM5000EX system may be connected to a radio base station for communication on a closed two-way radio network. An interface unit (IF935) is required and is given an ordinary subscriber number. If the radio system is simplex PTT then the subscriber number should be programmed with privilege “Simplex Always”...
The RM5000EX system may be used to multiplex sub-stations from a CB901. These substations will have the subscriber card in the RM5000EX instead of the CB901CA. One or more interlinks for audio will interconnect the the RM5000 (IF500)and the CB901(IF950). One data link is used for signaling (DNB100).
RM5000EX Operations Manual September 2018 CONFIGURATION One DNA100 is used as a programming interface to the EX500. The DNA100 has one RS232 port for connection to a serial port on a PC with VT100 terminal emulation. The DNA100 also include a serial to USB cable that can be used if a serial port is unavailable.
September 2018 Operations Manual RM5000EX ERROR HANDELING Misspelled command input will give the following error message: Unknown Command Parameter errors will print ERROR: and then prompt for the parameter again. HELP HELP COMMANDS Help lists all help commands in the Configuration program. Type HELP, H or ?.
Page 16
RM5000EX Operations Manual September 2018 SET COMMANDS >HS EX500 Set Commands: ====== ======================= Set Alarm Priority Set Call Number SCNU Set Call Number Undefined Set Call Priority SCID Set Caller ID Set Direct Access Set Direct Dial Set Device Type...
September 2018 Operations Manual RM5000EX > LINE EQUIPMENT The Line Equipment Number is the location of the intercom station in the central exchange. The number is hexadecimal in the range $00-$3D (62 subscribers). All individual station programming is done to this line equipment number. The programmed information may be listed by Line Equipment Number or by Call Number.
Page 18
RM5000EX Operations Manual September 2018 Example: Change the call numbers from default 100-155 to 200-255. This is useful when two or more exchanges are connected via Tie-line. Use the R(range) option to assign call numbers to a range of line equipment numbers.
September 2018 Operations Manual RM5000EX CALLER ID Each subscriber in the system has 12 alphanumeric characters for identification. This ID is available for display on the called station (DAD104) and for Event Logging (DNA100). Default is all spaces. PROGRAMMING The following commands are used for this feature:...
RM5000EX Operations Manual September 2018 List Call Number >SDT Call Number <10-99/*> : 11-14 Device Type(0=U 1=SUB 2=ICM 3=PTT 4=TIE 5=REM 6=ILK)<0..6> : 1 >LCN Call Number <10-99/*> : 11-14 Line Call Priority Network Address Remote Equ. Number Caller ID...
Page 21
September 2018 Operations Manual RM5000EX Program Channel in Idle Example: Add All Call Access (Privilege 4) for Subscriber number 11. >SPT Call Number <10-99/*> : 11 Privilege ID <1..14> : 4 <+/-/=> : + > Display the result. >LPT Call Number <10-99/*> : 11 Privelege ID <1-9/*>...
RM5000EX Operations Manual September 2018 DIRECT ACCESS There is one direct dial access number for each subscriber (DC shift). PROGRAMMING The following commands are used for this feature. Set Direct Access List Direct Access Example 1: Set direct access for subscriber 12 to dial subscriber 18.
September 2018 Operations Manual RM5000EX Call Number DD-0 DD-1 DD-2 DD-3 DD-4 DD-5 DD-6 DD-7 DD-8 DD-9 =========== ==== ==== ==== ==== ==== ==== ==== ==== ==== ==== ==== > SUBSCRIBER TIMERS There are 8 timers that can be set individually for each subscriber. A timer value of 0 means no time limit.
Page 24
RM5000EX Operations Manual September 2018 PERSONAL QUEUE Each intercom station has a Personal Queue. This queue is activated with Privelege ID number 7. All received calls are put in personal que and the intercom station will ring (2 sec on, 3 sec off) until the call is answered by pressing the 0 key.
September 2018 Operations Manual RM5000EX TRANSFER Call Transfer is used to distribute incoming calls to additional intercom station. Each subscriber has 7 transfer numbers. Transfers are processed sequentially, transfer 1 must activate before transfer 2 is activated and transfer 3 will not activate until transfer 2 is activated and so on. With each transfer there is a delay before the call is transferred.
RM5000EX Operations Manual September 2018 ANNUNCIATOR DISPLAY Any intercom station in the system may use an annunciator display (DAD104 or DS16) to display and answer calls in the personal queue. Each DAD104 is assigned to only one intercom station. PROGRAMMING The following commands are used for this feature.
September 2018 Operations Manual RM5000EX CAMERA SWITCHER The camera switcher is connected to the system using one dedicated DNA200. The camera switcher will connect a camera to a video monitor when the call is answerred by the intercom station equipped with a video monitor. Intercom stations with monitors are programmed with the address of the DNA200.
September 2018 BATTERY CHARGE MONITOR When the RM5000EX is equipped with battery backup the battery voltage is monitored. If the input voltage is higher then 25 Volt then the battery is being charged and the light LDP1_CH is ON. If AC power is lost or the battery charger fails then the battery voltage will fall below the 25 Volt and LDP1_CH will turn OFF.
September 2018 Operations Manual RM5000EX system. Each group contains the call numbers that are included in the page (group call) or excluded from the page (all call). The type of group is determined by the group privilege A. If a group has the A privilege it is an all call group, if not then it is a group call group.
Page 30
RM5000EX Operations Manual September 2018 Call Number <10-99/*> : 12-26 Group Number <0..7> : 3 <+/-/=> : + > Example 3: Exclude stations 15 from Group Call #3 (73). >SGCM Call Number <10-99/*> : 15 Group Number <0..7> : 3 <+/-/=>...
Page 31
September 2018 Operations Manual RM5000EX Display the result of example 1 - 5. >LGCM Group Call Number Number Receivers ====== ====== ================================================= > Page31 Ring-Master...
RM5000EX Operations Manual September 2018 GROUP CONFERENCE HANDSETS Group Conference may be used for Emergency Communication/Paging. Example: AA918 Master station with Annunciator for display of Faults DAD104 ($09). 11-16 GS921DAM Handset Stations with Push ToTalk button. 17-20 IF935 Paging Interface.
September 2018 Operations Manual RM5000EX FIREALARM Group Conference used for Emergency Communication/Paging. DS16 used for Login display and Faults Example: AA918 Master station with Annunciator for Log In Display and Faults DS16 ($09). 11-24 SS912/AN913EB Stations with Log In and Push ToTalk buttons.
RM5000EX Operations Manual September 2018 SECTORING Sectoring may be used for restricting calls to intercom stations in a sector. PROGRAMMING The following commands are used for this feature. Set Sector Members List Sector Members SSCT Set Sector Can Call Table...
Page 35
September 2018 Operations Manual RM5000EX >LSM Sector Members ====== ================================================= >LSCT From Can Call Sector Sectors ====== ============================================= 4 ...... 3 ......
Page 36
RM5000EX Operations Manual September 2018 TELEPHONE LINE INTERFACE IF934P The interface may be used as a speed dialer to a telephone number used for answering intercom calls from elevator intercoms in a night transfer mode of operation. The device type of the interface is set to PBX.
September 2018 Operations Manual RM5000EX BACKUP Backup generates programming commands required to restore the configuration of the EX500. These commands may be downloaded and stored in a file on the PC. This file can then be uploaded to restore the configuration of the EX500.
RM5000EX Operations Manual September 2018 INSTALLATION POWER HOOKUP Use DC power supply. Connect +24VDC TB1 pin 1 Connect Ground (minus) to TB1 pin 2 PROGRAM DISTRIBUTION TB2 pin 1 Audio inn + TB2 pin 2 Audio inn - TB2 pin 3...
September 2018 Operations Manual RM5000EX SWITCH PROGRAMMING SW2 on PCB1001 is the crisis alert network address. Network 1 Node 0 is normally used (Address $08): SYSTEM MEMORY DEFAULT The memory mustt be initialized when the system is first installed. All programmable features are set to factory default and all station are assigned call numbers .
Page 40
RM5000EX Operations Manual September 2018 Multi stage: SW2 1 and 2 on PCB500 (EX500) is used for selecting number of digits in call numbers when the system is defaulted.: Reserved 2 Digit Dialing (10-55) 3 Digit Dialing (100-155) 4 Digit Dialing (1000-1055)
Page 41
September 2018 Operations Manual RM5000EX Page41 Ring-Master...
Page 42
RM5000EX Operations Manual September 2018 Intercom Connections Data Connections LC500 EX500 TELEPHONE LINE PCB1002 PCB1001 TB17 TWISTED PAIR CB400 TWISTED PAIR TWISTED PAIR TB16 TWISTED PAIR PROGRAM DISTRIBUTION INPUT AA915 +5V OUT AA919 TWISTED PAIR RS485 RS232 DNA100 TB11 TWISTED PAIR...
September 2018 Operations Manual RM5000EX TWO STAGE EX500 Two EX500 are interconnected to form one system. One to four audio links and one RS485 data link are used to connect the two centrals. PROGRAMMING STAGE 1 (address $08): Default System Memory to Stage 1 with 3 call digits (page 38).
Page 48
RM5000EX Operations Manual September 2018 THREE STAGE EX500 Three EX500 are interconnected to form one system. Two to four audio links and one RS485 data link are used to connect the three centrals. PROGRAMMING STAGE 1 (address $08): Default System Memory to Stage 1 with 3 call digits (page 38).