Vante 3120 Instruction Manual

Tube sealing system
Hide thumbs Also See for 3120:

Advertisement

Quick Links

INSTRUCTION
MANUAL
MODELS 3120/3807
Tube Sealing System
Doc. No. 38070815-00-00 Rev. E

Advertisement

Table of Contents
loading

Summary of Contents for Vante 3120

  • Page 1 INSTRUCTION MANUAL MODELS 3120/3807 Tube Sealing System Doc. No. 38070815-00-00 Rev. E...
  • Page 2 This page intentionally left blank...
  • Page 3 Vante ® 3480 E. Britannia Dr., Suite 120 Tucson, AZ 85706 USA Telephone (520) 881-6555 (520) 323-9055 Toll Free (877) 565-5557 Part No. 38070815-00 Rev. E 9/12 Vante ®...
  • Page 4 This page intentionally left blank...
  • Page 5: Intended Audience

    Application The Model 3120 RF Generator and Model 3807 Sealer create a system for making seals on tubing made of RF-reactive thermoplastic materials such as polyurethane, polyvinylchloride (PVC), Ethylene vinyl acetate (EVA), certain types of nylons and certain co-extrusions.
  • Page 6: Safety Symbols

    Vante assumes no liability or obligation nor guarantees system performance. Proprietary Information All rights are reserved. Copying of the protected designs associated with the Model 3120 or the Model 3807 Sealer system is strictly prohibited without the prior written consent of Vante.
  • Page 7: Table Of Contents

    Table of Contents Preliminary Information ....................v Document Scope ......................v Intended Audience ......................v Application ........................v User Alerts ........................v Safety Symbols......................vi Exclusions and Limits of Liability ................vi Proprietary Information ....................vi Table of Contents ......................vii Table of Figures ......................viii Description ........................1 Tube Sealer System ....................1 Theory of Operation....................1...
  • Page 8: Table Of Figures

    Table of Figures Figure 1.1 Model 3120 RF Generator ..................3 Figure 1.2 Model 3807 Large Sized Tube Sealer..............3 Figure 1.3 Serial Plates ......................4 Figure 1.4 Fuse Labels ......................4 Figure 2.1 Interface Connections ....................5 Figure 2.2 Hand Held Sealer ......................7...
  • Page 9: Description

    (RF) to seal, form and/or weld RF reactive thermoplastic materials in a variety of tubing sizes. The Model 3120 RF Generator is the foundation of the system. It must be connected to the Model 3807 Large Sized Tube Sealer to complete the system and perform the required operation.
  • Page 10: Sealer Interface

    Reference the Radio Frequency System Safety Considerations section included at the end of this manual. 1.3.3 The Model 3120 Generator has a thermal protection circuit which will cause the unit to shut down if internal temperatures exceed 55°C. After a short period of time (when internal temperatures are below 55°...
  • Page 11: Figure 1.1 Model 3120 Rf Generator

    BNC Connector RF Output Air line Connection Clamp Time Adjustment Power and RF On Indicator Light Power Control Adjustment Dwell Time Adjustment Control Port Figure 1.1 Model 3120 RF Generator Sealing Jaws Cable Assembly Connection Figure 1.2 Model 3807 Large Sized Tube Sealer.
  • Page 12: Operating Environment

    Figure 1.3 Serial Plates Figure 1.4 Fuse Label 1.6.3 Refer to the serial number when contacting Vante or one of its authorized service centers. Operating Environment 1.7.1 The Sealer will perform effectively when used in a controlled environment. Actual...
  • Page 13: System Setup

    2.1.2 Check to see that the power cord plug matches the power receptacle for the country in which the system is being used. If it does not, contact Vante. Do not connect the power cord to AC mains at this time.
  • Page 14: Adjustment And Operation

    2.2.7 Set the RF Dwell time Adjustment located on the front of the Generator to a low setting, e.g., “1” for a small tube, “3” for a larger tube. One complete revolution of the knob is about 2.6 seconds. If you have any questions, contact Vante for a recommended setting.
  • Page 15: Figure 2.2 Hand Held Sealer

    Vante Model 3120/3807 ® WARNING: Keep the outside of the tubing and equipment clean and dry! NOTE: Releasing the trigger will immediately turn off RF power; however, the jaws will remain clamped dependant on front clamp time. NOTE: Polyurethane, PVC, EVA and certain types of nylons are the only materials that can be sealed.
  • Page 16 NOTE: The Model 3120 RF Generator is equipped with a thermal protection circuit which will cause the unit to shut down if unusually high levels of usage occur. In such case, the power-on switch on the front of the panel will remain illuminated, the fan will continue to run, but there will be no RF power output.
  • Page 17: Maintenance And Repair

    CAUTION: Do NOT, under any circumstances, submerge the Sealer in any kind of liquid. This will damage the sealing jaws and void the warranty. 3.1.1 The only maintenance required for the Model 3120 RF Generator is ensuring the fan intake and air exhaust ports are free of accumulated dust to ensure proper airflow.
  • Page 18 Vante Model 3120/3807 ® This page intentionally left blank...
  • Page 19: Radio Frequency System Safety Considerations

    RF energy. However, misuse or direct contact between tissue and RF electrode(s) can result in severe RF burns. RF Effects On Pacemakers 4.3.1 There is no evidence that Vante RF instruments interfere with the function of modern cardiac pacemakers. Electrical Safety 4.4.1 Vante RF devices meet or exceed appropriate electrical safety standards, and pose no...
  • Page 20: Rf Effects In Potentially Explosive Atmospheres

    ® RF Effects In Potentially Explosive Atmospheres 4.6.1 Do not operate Vante RF instruments in any area with a potentially explosive atmosphere. It is possible for the RF electrodes to arc, initiating an explosion or fire. WARNING: Vante recommends strict adherence to the procedures specified in the instrument Instruction Manual.

This manual is also suitable for:

3807