Vante ® 3480 E. Britannia Dr., Suite 120 Tucson, AZ 85706 USA Telephone (520) 881-6555 (520) 323-9055 Toll Free (877) 565-5557 Part No. 38070815-00 Rev. E 9/12 Vante ®...
Application The Model 3120 RF Generator and Model 3807 Sealer create a system for making seals on tubing made of RF-reactive thermoplastic materials such as polyurethane, polyvinylchloride (PVC), Ethylene vinyl acetate (EVA), certain types of nylons and certain co-extrusions.
Vante assumes no liability or obligation nor guarantees system performance. Proprietary Information All rights are reserved. Copying of the protected designs associated with the Model 3120 or the Model 3807 Sealer system is strictly prohibited without the prior written consent of Vante.
Table of Contents Preliminary Information ....................v Document Scope ......................v Intended Audience ......................v Application ........................v User Alerts ........................v Safety Symbols......................vi Exclusions and Limits of Liability ................vi Proprietary Information ....................vi Table of Contents ......................vii Table of Figures ......................viii Description ........................1 Tube Sealer System ....................1 Theory of Operation....................1...
(RF) to seal, form and/or weld RF reactive thermoplastic materials in a variety of tubing sizes. The Model 3120 RF Generator is the foundation of the system. It must be connected to the Model 3807 Large Sized Tube Sealer to complete the system and perform the required operation.
Reference the Radio Frequency System Safety Considerations section included at the end of this manual. 1.3.3 The Model 3120 Generator has a thermal protection circuit which will cause the unit to shut down if internal temperatures exceed 55°C. After a short period of time (when internal temperatures are below 55°...
BNC Connector RF Output Air line Connection Clamp Time Adjustment Power and RF On Indicator Light Power Control Adjustment Dwell Time Adjustment Control Port Figure 1.1 Model 3120 RF Generator Sealing Jaws Cable Assembly Connection Figure 1.2 Model 3807 Large Sized Tube Sealer.
Figure 1.3 Serial Plates Figure 1.4 Fuse Label 1.6.3 Refer to the serial number when contacting Vante or one of its authorized service centers. Operating Environment 1.7.1 The Sealer will perform effectively when used in a controlled environment. Actual...
2.1.2 Check to see that the power cord plug matches the power receptacle for the country in which the system is being used. If it does not, contact Vante. Do not connect the power cord to AC mains at this time.
2.2.7 Set the RF Dwell time Adjustment located on the front of the Generator to a low setting, e.g., “1” for a small tube, “3” for a larger tube. One complete revolution of the knob is about 2.6 seconds. If you have any questions, contact Vante for a recommended setting.
Vante Model 3120/3807 ® WARNING: Keep the outside of the tubing and equipment clean and dry! NOTE: Releasing the trigger will immediately turn off RF power; however, the jaws will remain clamped dependant on front clamp time. NOTE: Polyurethane, PVC, EVA and certain types of nylons are the only materials that can be sealed.
Page 16
NOTE: The Model 3120 RF Generator is equipped with a thermal protection circuit which will cause the unit to shut down if unusually high levels of usage occur. In such case, the power-on switch on the front of the panel will remain illuminated, the fan will continue to run, but there will be no RF power output.
CAUTION: Do NOT, under any circumstances, submerge the Sealer in any kind of liquid. This will damage the sealing jaws and void the warranty. 3.1.1 The only maintenance required for the Model 3120 RF Generator is ensuring the fan intake and air exhaust ports are free of accumulated dust to ensure proper airflow.
Page 18
Vante Model 3120/3807 ® This page intentionally left blank...
RF energy. However, misuse or direct contact between tissue and RF electrode(s) can result in severe RF burns. RF Effects On Pacemakers 4.3.1 There is no evidence that Vante RF instruments interfere with the function of modern cardiac pacemakers. Electrical Safety 4.4.1 Vante RF devices meet or exceed appropriate electrical safety standards, and pose no...
® RF Effects In Potentially Explosive Atmospheres 4.6.1 Do not operate Vante RF instruments in any area with a potentially explosive atmosphere. It is possible for the RF electrodes to arc, initiating an explosion or fire. WARNING: Vante recommends strict adherence to the procedures specified in the instrument Instruction Manual.