The instruction manual describes the maximum available range of functions in the WBGT measurement ......................44 testo 400. testo 650 and testo 950 have limited derived functions in relation to the probes NET measurement......................45 which can be connected and the parameters which can be analysed - See table: Pressure measurement ....................46...
Initial operation of instrument Initial operation of instrument First measurement A quick introduction is provided by the instrument and Please read prior to operation system descriptions on pages 6-9. Do not measure on live parts. This symbol stands for further information . Look for the adequate word in the keyword context, further Observe admissible storage and transport temperature as well as the operating temperature informations are available on the indicated page.
Description of instrument Description of instrument * testo Comsoft software, Attachment 5 function fields are set up around the data display which provide information on Infrared for printer Version 3.0 or newer, is required additional functions during measurement. In order to set up these functions which can interface for for data exchange with your PC.
System description Menu overview Configuration Function fields M M a a i i n n m m e e n n u u MEASURING MEMORY Start Lenzkirch EADOUT Lower limit 41. 3 Cycle Time ROGRAMME 25. 1 Upper limit Main m m enu 11.
Page 6
Menu overview Menu overview Allocation options of function buttons Allocation options of function buttons Hold Start freezes the last current reading on the display. starts a measurement program. Lenzkirch MAXMIN Stop 41. 3 shows the largest/smallest display value since stops a measurement program. switching on.
Page 7
Initial operation Attachable printer Attachable printer Part no. 0554.0570 Part no. 0554.0570 The testo 400/650/950 instruments have an interface for Data transfer connecting the attachable printer. Press to release the lock. The attachable printer has a powerful bi-directional infrared interface with data buffer in the printer. Once the...
Operating instructions Instrument and error messages Testo printer, Part no. 0554.0545 Error message Possible causes Error elimination Instrument error Numerous! Contact our Note: ← Note number! 072304EF00 service department The printer switches to power save after 10 minutes of inactivity. Memory error No memory space available Erase memory...
Configurations assessed years later. The values measured in the measuring instruments of the testo 400/650/950 series are constantly accompanied by a location (top right in display). This information as well as date and time appear as additional information in all of the printouts and in the PC files.
Pt100 precision probe - Printout with attachable printer If a barcode label is attached on location (produced using Comfort software, testo 400 module) this can be read in with the barcode pen. The measuring instrument searches for the location in Adjusting ...
Temperature measurement Temperature measurement 0.01 °C resolution for Pt100 and thermocouple probe Pt100 probes are generally shown with a resolution of 0.01 °C. This Optimum accuracy only applies in the environment of the calibration resolution is possible for a reading to max. +300 °C. At higher point.
Page 12
Temperature measurement Temperature measurement , k factor, quick final value extrapolation Surface correction Surface probes conduct heat from the surface being measured following the first contact. For this reason the measured result is This function can only be used to the full when used with lower than the true surface temperature without the probe (the testo Comsoft software.
The humidity probes 0636.9740 and 0636.9715 as well as 0635.1540 can be calibrated using When used with testo 400/650, the multi-function humidity probes from Testo (e.g. the hand-held instrument (no buttons on probe). All other humidity probes are adjusted using 0636.9740) show readings for relative humidity and the corresponding temperature after switch-...
Page 14
Measurement: When measuring ensure that the probe is lying firmly on the material being measured. Connecting to testo 400 or testo 650 reference instruments: If the instrument is switched on with the 0636.0565 probe attached, the instrument shows the Note: values in kΩ.
Falling trend activity depends on temperature. In order to measure the aw value you will need, in addition to the testo 400/testo 650 measuring instrument, a highly accurate humidity probe and a measuring device (accessories). aw value It consists of a pressure tight measuring chamber which is 0 0 .
Automatic storing Automatic storing Task: Automatic storing of the humidity/temperature conditions in front of and behind an air PROBE - S off? MOOTH heater together with two humidity probes, 100 values with printout of time dependency on - Surf corr: 00 %? (for probe 1 and 2!) an attachable printer.
Page 17
Automatic storing Automatic storing The following sub-menus should be checked or set before storing: PROGRAMME - E Memory Full stops the program if the complete memory is full. Wrap Around PROGRAMME - S - Lower limit/Upper limit TART Stores until storing has been interrupted by the the “Stop” function A probe must be connected via which the program can be button (appears automatically in the function bar once the started .
Page 18
Automatic storing Automatic storing 3. Measuring in accordance with the previous example Plug in the humidity probes on location and switch on the measuring instrument. Set the location (in this case “heater”) at the top right of the display using the arrow buttons. Set the function display in the top left to “Store symbol”...
Velocity measurement Automatic storing Function button “Send” Task: Measuring the volume flow in a duct with a 500 mm diameter and vane probe All current readings are transmitted to your PC as ASCII (Ø 16 mm), printout on attachable printer. files including unit via the RS232 interface once the Send button is pressed.
Page 20
Velocity measurement Velocity measurement Volume flow funnel Mean Averaging is called up via and multi-point measurement is selected. A volume flow funnel is required for calculating volume flow at a sucking opening (grid or button tool with dual wall clearance). The funnel opening must cover the grid fully (max. 200 x 200 mm Start While the vane is moved over the duct cross-section, each confirmation stores a single...
Page 21
Velocity measurement Velocity measurement Density “rho”: setting parameters manually Setting parameters automatically If you have connected a temperature, humidity or absolute pressure probe their values are accepted directly if you confirm the displayed value via under SPECIAL - P ARAMETER Temp., Humidity or Abs.
Page 22
Start The current measured value appears after is pressed. are available Similar to all other thermal probes the 0628.0009 probe is pressure-compensated in testo 400. Start as function buttons. starts a timed mean calculation for the specified duration (see time For this reason set the current absolute pressure in the main menu under Special - Parameter.
WBGT measurement NET measurement The WBGT (Wet Bulb Globe Temperature) climate index is determined using the WBGT probe in The NET (Normal Effective Temperature) climate index is determined using the 3 function probe accordance with DIN 33403 and ISO 7243. The WBGT index is used to determine the maximum in accordance with DIN 33403.
Pressure measurement Current/voltage measurement Once a pressure probe has been connected and the measuring instrument has been switched Current and voltage can be measured with the 0554.0007 probe. on the pressure value is displayed with the unit set in the measuring instrument. Note! If 2 probes are connected the signals must refer to the same reference potential.
Barometric pressure can be measured, saved and documented (on PC or as a printout on site) using the testo 400 or testo 650 measuring instrument together with the absolute pressure probe (Part no. 0638.1645). Connect absolute pressure probe (part no. 0638.1645) to measuring instrument and switch on.
Power supply CO measurement The instruments in the testo 400 series can be operated using the following: The connected 0632 1247 probe is initialised in the switch-on phase. For this reason the • 4 standard batteries (Type: Al/Mn round cell) incl. 1 Li button cell to store RAM data when...
±0.02 m/s (2 to 4.9 m/s) Resolution 0.1 °C ±0.04 m/s (5 to 20 m/s) testo 650 and testo 950 can be upgraded to have the full functions of testo 400. We will Accuracy ±0.4 °C (-150 to +150 °C) Current/voltage measurement gradually introduce branch-specific and user-specific software updates for the instruments.
1.5 V or NC rechargeable batteries 1.5 V or NC rechargeable batteries Humidity/pressure module (upgrades 950 to 650) 0450.4002 Accessories Spare paper, Part no. 0554.0569 Velocity module (upgrades 650 to 400) 0450.4003 Humidity/pressure/velocity module (upgrades 950 to 400) 0450.4004 VAC module (for testo 400) 0450.4010...
Page 29
Roller probe for surface meaurements on rollers and rotating -200 to +1100°C 0600.5893 -50 to +240 °C d)Outer casing: Inconel 2.4816 PUR coiled drums, max. circumferential velocity 18 to 400 m/min, 0600.5093 Class 2 cable Handle for plug-in measuring tips PUR coiled cable rated length = 274 mm, probe tip: Ø...
Page 30
Connection cable Part no. Add. probes Meas. range Accuracy * Connection cable Part no. for testo 950, 650, 400 for testo 950, 650, 400 ±5 ppm (0 to 100 ppm) CO probe 0 to 500 ppm 0632.1247 ±5 % of m.v. (rem. range)
Page 31
Ordering data Ordering data Caps for all humidity probe types Ø 12 and 21 mm Humidity/temperature probes for tough industrial applications Connection cable Part no. for testo 650, 400 Measuring range Accuracy * Connection cable Part no. 0554.0665 Metal protection cage, material: stainless steel V4A. Quick adjustment time, robust Ø...
Page 32
0635.9640 extraction systems telescope, Ø 25 mm -30 to +140 °C * ± 1 % of m.v. a) Measuring range: 20 to 400 m /h; funnel factor 22 0554.0400 ± 0.1 m/s Plug-in vane for integrating velocity measurement. b) Measuring range: 20 to 400 m /h;...
-Lithium battery ....15 Any faults occurring during the warranty time will be repaired by Testo AG, Testo’s Adjustment ....19 -Memory error .
Page 34
Index Testo worldwide ARGENTINA CHILE EL SALVADOR IRAN NET ......45 storing, Automatic ....30 Offset correction, See: Adjustment -Cycle time .
Page 35
Testo worldwide notes NETHERLANDS SLOVAKIA TURKEY SLOVENIA NEW ZEALAND UNITED ARAB EMIRATES NICARAGUA SOUTH AFRICA NORWAY SPAIN VENEZUELA PERU SWEDEN PHILIPPINES SWITZERLAND VIETNAM POLAND SYRIA PORTUGAL TAIWAN, R.O.C. ROMANIA THAILAND Stand: 24.01.03 www.testo.com SINGAPORE / MALAYSIA / TUNISIA 24.01.03 INDONESIA www.testo.com...