Download Print this page

Gymnova 3425 Assembly Instructions Manual

Retractable vaulting table

Advertisement

Quick Links

45 RUE G. DE FLOTTE
13012 MARSEILLE (FRANCE)
TEL : 33.(0).4.91.87.51.20
FAX : 33.(0).4.91.93.86.89
www.gymnova.com
info@gymnova.com
Fixation between
ground and wall
(Ref.: 3425)
Warning :
This equipment must be installed by a qualified person.
This equipment must be used under the supervision of a qualified person.
This equipment cannot be used for any other purpose than its initial purpose.
Conformity :
This equipment is in accordance with the EN 913 norm "Gymnastics equipment - Fonctional safety requirements and
test methods".
Recommendations :
The French norm NF S 52-400 advises :
- to preserve this sheet for ulterior needs (checking, maintenance...).
- to make periodic preventive maintenances.
- to make checkings once a year or more frequently according to its use.
Maintenance :
The fixings, the articulations, also the state of protection pads must be verified, before each use.
Packing detail :
Package
3451/00
Dressed
Ref.
body only
3425
1
Retractable Table
Floor / Wall
Folding extension
3426
1
Retractable Table
Wall
Folding extension
3427
Retractable Table
1
Floor
Folding extension
Volume & Weight
0,724m
per package
28 kg
In line our policy of constant product improvement, we reserve the right to modify ours products from that illustrated without notice.
ASSEMBLY INSTRUCTIONS
R
ETRACTABLE
ON FOLDING
Fixation on wall
(Ref.: 3426)
In case of problem,
phone to our
technical service :
+33.4.91.87.51.20
3451/30
3497/30
3423/00
Retractable
Wooden
Edge of the pit
interface
support
Slide
platform
M'2002
1
1
1
1
1
1
3
3
3
0,063m
0,05m
0,05m
7 kg
8 kg
10 kg
V
T
AULTING
ABLE
E
M'2002
XTENSIONS
446/20
446/09
446/30
Complete
Wall
Floor
folding
fixation
fixation
extension
piece
Kit
1
1
1
1
1
2
1
1
1
3
0,155m
3
0,003m
3
0,023m
46 kg
1 kg
6 kg
NM190
Fixation on the
ground (Ref.: 3427)
Take care of
precautions for
STORAGE
2924
2010
2005
Folding
Chimical
Chimical
extension
anchors
anchors
total volume
Protection
(4)
(10)
1
1
1
1
1
3
3
3
0,064m
0,003m
0,010m
3
5 kg
1 kg
3 kg
15/01/03
3425
3426
3427
Number of
packages
& weight
8
1,11m
3
106 kg
8
3
1,11m
102 kg
8
3
1,14m
113 kg

Advertisement

loading
Need help?

Need help?

Do you have a question about the 3425 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gymnova 3425

  • Page 1 XTENSIONS 3427 info@gymnova.com Fixation on the ground (Ref.: 3427) Fixation on wall (Ref.: 3426) Fixation between ground and wall (Ref.: 3425) Take care of precautions for STORAGE In case of problem, phone to our technical service : +33.4.91.87.51.20 Warning : This equipment must be installed by a qualified person.
  • Page 2 I . F .: 3427) LOOR MOUNTED FOLDING EXTENSION 1.1. Preparing and mounting the low swivel plate (8) to the floor: 1 – Trace the position (P) of the slide pivot (7) on the ground, and the axes for the bracing mounts, as shown in figure 1. 2 –...
  • Page 3 II . W .: 3426) ALL MOUNTED FOLDING EXTENSION 2.1. Preparing and mounting the wall plates (14): 1 – Trace a vertical line on the wall as shown in figure 4. 2 – To position the top plate at height "A", take height "H" as shown in the table in figure 5 (Check that the wall is perpendicular: can lock the verticality of the 2 plates).
  • Page 4 III . F .: 3425) LOOR WALL MOUNTED FOLDING EXTENSION 3.1. Preparing and fastening the low pivot (8) to the floor and the wall plate (14): 1 – Trace the position (P) of the slide pivot (7) on the floor as shown in figures 7 and 8 (Make sure the wall is perpendicular: 100 mm offset from the line of the top plate).
  • Page 5 Precautions for storing the Table It is essential not to put anything on the body: its dynamic structure (internal) and the curve of the take-off zone (external) could be irreversibly damaged (Do not sit on it either !!!). When it is dismantled: - Never lay it on the front tip, - Store it preferably upside down or on its side.

This manual is also suitable for:

34263427