1. ON—OFF OPERATIONS
Use the
key to Opening/Closing operations.
When pressing the key once, the device will switch on
or off.
Off Position

2. OPERATION MODE SETTINGS

While the device is in the On Position, operation mo-
de can be changed with
Note: The active mode icon flashes on the panel.
Ventilation Mode
On Position
key.
Cooling Mode
Cooling
Heating
Auto
Setpoint
Room Tmp
Air Quality
Sup. Air Tmp
Out. Air Tmp
Supply Air Fan Speed
Auto-5-4-3-2-1

3. SETPOINT SETTING

Setpoint Setting

4. MONITORING DIFFERENT TEMPERATURES

The sensor values, which is measured by main control-
ler, are displayed alternately on the panel. In this app-
lication "Room Temperature, Supply Air Temperature,
Outdoor Air Temperature" sensors can be measured
by main controller.
Note 1: If Room Temperature Sensor is not connected to
main controller, Temperature Sensor value of the panel is
measured.
Ventilation
Electrical Heater Stages
Exhaust Air Fan Speed
1-2-3-4-5-Auto
Main Digits
Alarm Notification
Auxiliary Digits
Heating Mode
Use the ▲ and ▼ keys
to adjust the setpoint. If
the keys are pressed one
time, setpoint will be
changed 1 °C. Use the ▲
key to increase the set-
point, use the ▼ key to
decrease the setpoint.
Setting range: 5 °C—30
°C.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVANCED J8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Jakka ADVANCED J8

  • Page 1 MANUAL for JAKKA ADVANCED CONTROLLER Cooling Ventilation Electrical Heater Stages Heating KEYPAD and PANEL DESCRIPTION Auto Setpoint ON/OFF — On/Off Key MODE — Mode Key Room Tmp Air Quality — Fan Key Sup. Air Tmp ▲ ▼ SET — Increment/Decrement Key Out.
  • Page 2 MANUAL for JAKKA ADVANCED CONTROLLER Note 2: If Supply Air Temperature Sensor is connected and 6. FAN LOGIC SETTING necessary settings are made, Supply Air Temperature value is displayed in the panel at regular intervals. It has no cont- rol function.
  • Page 3 MANUAL for JAKKA ADVANCED CONTROLLER 8.3 DAMPER CONTROL 7.3 AL:03 AIR FILTER ALARM (NO) In the scenarios contained in the Damper control, one If contact is in the closed relay output reserved into for Damper control. position or device works up...
  • Page 4 MANUAL for JAKKA ADVANCED CONTROLLER Outdoor Control Activate: 9.3 BMS ADDRESS SETTING Firstly, “Main Parameter” must be replaced as “7”, After logging into the servi- by the MODE and ce menü, using the MODE keys. and FAN keys, select the 00.
  • Page 5 MANUAL for JAKKA ADVANCED CONTROLLER 10. MOUNTING INFORMATION 1) Use standart junction box. 2) Remove the 3) Secure the 4) Make the 5) Attach the clip Hole distance must be 60mm front panel cable connecti- at the top first, rear panel by center to center.

Table of Contents