Co2meter iSense CM-0180 User Manual

Isense remote oxygen safety alarm

Advertisement

Quick Links

User Manual
iSense Remote
Oxygen Safety Alarm
CM-0180 - 25% Oxygen 
CM-0181 - 95% Oxygen 
 
Copyright © 2014 CO2 Meter. All Rights Reserved.
iSense Oxygen Transmitter - Manual
TABLE OF CONTENTS ...................................................................................  2
WELCOME ...................................................................................................  3
IMPORTANT SAFEGUARDS...........................................................................  4
DEVICE SPECIFICATIONS ..............................................................................  5
PACKAGE CONTENTS ...................................................................................  6
GASLAB ® SOFTWARE ..................................................................................  6
STANDARD OPERATION  . ............................................................................ 11
ENTERING THE SERVICE MENU .................................................................. 12
PERFORMING AN ATMOSPHERIC SPAN CALIBRATION ................................ 12
PERFORMING A 0% OXYGEN ZERO POINT CALIBRATION ............................ 12
TERMINALS CONNECTORS ......................................................................... 13
MODBUS / RS-485 ..................................................................................... 13
SUPPORT  . .................................................................................................. 20
WARRANTY ............................................................................................... 20
 
RETURNS  . .................................................................................................. 20
LIABILITY ................................................................................................... 21
CONTACT US ............................................................................................. 22
Rev. 27 October 2014

Table of Contents

 ....................................................................... 7
 ........................................................................................... 8
 ................................................................................................... 11
  . ............................................................................................. 14
 ......................................................................................... 14
 ........................................................................................ 15
 ................................................................................................... 16
 
 ..................................................................................... 16
 ................................................................................................... 16
 
CO2Meter.com
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 .............................................. 17
 
 
 
 
 
Pg. 2 of 21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iSense CM-0180 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Co2meter iSense CM-0180

  • Page 1: Table Of Contents

    Oxygen Transmitter – Manual CO2Meter.com Table of Contents User Manual   TABLE OF CONTENTS ...................  2   WELCOME ....................  3   IMPORTANT SAFEGUARDS................  4 iSense Remote   DEVICE SPECIFICATIONS ................  5   PACKAGE CONTENTS ...................  6 Oxygen Safety Alarm   GASLAB ® SOFTWARE ..................  6    ............... 7 INIMUM  YSTEM  EQUIREMENTS  ................... 8   UICK  TART ...
  • Page 2: Welcome

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Welcome Important Safeguards To reduce the risk of fire, electrical shock and/or injury to persons,  Thank you for purchasing the iSense Remote Oxygen Safety  basic safety precautions should always be followed when using  Alarm. This unit allows you to measure oxygen in inaccessible  electrical appliances, including the following:  areas. The iSense is a long life 0‐25% oxygen level transmitter  that provides multiple analog linear outputs of O2  1. READ ALL INSTRUCTIONS BEFORE USING THIS DEVICE!  concentrations. It’s designed to be rugged, maintenance‐free  2. Use only the supplied power supply to operate the unit.   and can be calibrated in normal air of any known oxygen  3. Ensure that when sampling in a closed environment that the  concentration.  tubes are securely fashioned to the device.  Our goal is to make high‐quality, low‐cost gas detection and  4. Do not operate with a blocked off sample path.  indoor air quality products available to you.  5. Do not operate the device if it is malfunctioning.  6. Do not install the device outside in exposed conditions. Due to ...
  • Page 3: Device Specifications

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Device Specifications Package Contents Please verify that your package contains the following items before  Measuring Range:    using the unit:  25% O2  0‐25% vol.  Contents:  95% O2  0‐95% vol.  (1) Meter  Repeatability:     (1) Certificate of Calibration   (1) User Manual  0‐25% CO2  ± 0.05%, ± 1 % of measured value  (1) Power supply  0‐95% O2  ± 0.02%, ± 1 % of measured value ...
  • Page 4: Minimum System Requirements

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com select “Run” when prompted by your browser (as shown on Figure 1  below).  Minimum System Requirements To utilize our free software, your computer must meet the following  requirements:    Windows XP SP3 or higher   Microsoft .Net Framework 3.5 SP1   Pentium 4 (or newer) operating at 2.4Ghz or faster   1GB of Random Access Memory (RAM)   Hard disk space with at least 20 Megabytes (MB) free (200+MB  recommended for logs and application files)  Software is compatible with 64‐bit operating systems and is fully  tested with Windows 7.    Figure 1: Install GasLab® online (Internet Explorer 9 shown)  Quick Start Guide Make sure you read through these instructions thoroughly before  using your meter. This guide will help you familiarize with your meter  in order to be as productive as you need to be in the least amount of ...
  • Page 5 Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Oxygen Transmitter  Oxygen sensor that’s communicates to  Display  the remote via Modbus protocol  Shows O2 concentration level and data  logging status (optional)  Barb Fittings  Mute Button  Connect to sampling system for closed  The screamer activates when the values  loop sampling or diffusion, the unit  of Oxygen are lower than 19.0% and it  comes with protectors for the sensor.  will last 30 seconds.    Data M12 Connector  Modbus connection from the remote to  the Oxygen Transmitter    Display    Shows O2 concentration level  USB  Power Input  Through the USB you can calibrate,  Plugging our 24 VDC power supply  collect data in real time, download data  include, you can Turn ON/OFF the unit. ...
  • Page 6: Description

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Description Entering the Service Menu Display – Main interface to view current sensor readings and menu  To enter the service menu the buttons must be pressed in a factory‐set  state. Will blink “STRT” upon applying power while the sensor warms  order. This code can be customized before shipment but by default will  up and stabilizes.   be 1‐2‐3. The buttons must be pressed within a half second of each  LEDs  – are in for lower right corner of the unit on the main PCB and  other, else the unit will return to standard operating mode. When in  are labeled S, E and P.  the service menu the unit will not update the current O2 readings.  Once you enter the menu the display will read “2222”.   S LED – Status LED. Blinks every time a complete measurement cycle is  performed and the value is updated. Serve’s as a heartbeat for  transmitter operation.   Performing an Atmospheric Span Calibration E LED – Error LED. Will light if any abnormal conditions are detected  1. Allow sensor to stabilize for at least 1 hour  within the device, primarily the sensor falling out of its recommended ...
  • Page 7: Terminals Connectors

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Input Registers Terminals Connectors 1. O2 Value, x10  1. VDC = G‐ G+  2. Raw ADC Value  2. O2 4‐20mA = SIG GND  3. RS‐485 INTERFACE = A B GND  Holding Registers 4. RESET = RST  1. O2 Span Value (4 byte floating number, part 1)  2. O2 Span Value (4 byte floating number, part 2)  3. O2 Pot Value  4. 4‐20mA output  Zero Value  5. 4‐20mA output Span Value (4 byte floating number, part 1) ...
  • Page 8: Powering The Unit

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Powering the Unit LCD Display The unit can be powered by hardwiring 24 VDC power through the  The Liquid Crystal Display (LCD) screen shows the following features:  MDCM‐4FP‐2M Cable (included) but sampling units can also be   CO2 in percentage format (##.##%) for  100%  powered by the included 24VDC International wall power supply.  Theory of Operation The zirconia oxygen sensor utilizes solid‐state electrochemical  reactions to produce a voltage proportional to the current oxygen. This  voltage is then digitalized and filtered to a usable value. The oxygen  sensor has also been factory calibrated to meet specifications.  Calibration The calibration process varies depending on the type of unit and  whether it has optional data logging functionality or not. All units are  factory‐calibrated with multiple reference points of gas, and have been  verified to be accurate within their specific functionality before  shipment. However, if the unit is severely jolted or otherwise  mechanically disturbed, the sensor can drift requiring recalibration. All  calibration procedures follow a single‐point calibration routine that    effectively shifts the zero‐point of the O2 sensor. ...
  • Page 9: Calibrating Using Modbus Or Pc Connection

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Calibrating using MODBUS or PC Connection You can Download the software directly and free from this link in our  website. (http://www.co2meter.com/pages/downloads)   More precise calibrations can be performed using the PC connection.  The unit can be attached to a PC using an optional USB to RS‐485  cable, available on our website, or via a mini‐USB cable to the internal  USB connection. Using the USB cable you can connect the unit to the  computer and start configuring through the software GasLab ®.    Calibration of the Oxygen Sensor    In the desktop software application O2 can be calibrated individually.  The O2 sensor can be calibrated to 0% and then to 20.9%.  During normal operation 0% calibration of the oxygen transmitter  should not be necessary.   Calibration can also be performed over MODBUS, see additional  documentation for MODBUS registers.     Calibration can be performed using either 0% CO2 calibration gas  (typically nitrogen, Argon, etc.), or using a fresh source of air, assumed  to be approximately 20.9% O2.  Attach calibration gas to the unit and connect the unit to a personal  computer. Open the calibration screen in the GasLab ® software. Click ...
  • Page 10: Support

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Support concentration is stable, the unit should instantly reflect the calibrated  value. This can be confirmed by watching the display. To see the  The quickest way to obtain technical support is via email. Please send  calibration value in real time, click in the “Auto Logging” button to  all support enquires to support@co2meter.com. In your email, please  capture these values before opening the configuration screen.   include a clear, concise definition of the problem and any relevant    troubleshooting information or steps taken so far, so we can duplicate  the problem and quickly respond to your inquiry.  Warranty This unit comes with a 1YEAR (warranty period) limited manufacturer’s  warranty, starting from the date the unit was shipped to the buyer.  During this period of time, CO2Meter.com warrants our products to be  free from defects in materials and workmanship when used for their  intended purpose and agrees to fix or replace (at our discretion) any  part or product that fails under normal use. To take advantage of this  warranty, the product must be returned to CO2Meter.com at your  expense. If, after examination, we determine the product is defective,  we will repair or replace it at no additional cost to you.  This warranty does not cover any products that have been subjected    to misuse, neglect, accident, modifications or repairs by you or by a  Real‐time capture  third party. No employee or reseller of CO2Meter.com’s products may  alter this warranty verbally or in writing.  Zero or Fresh Air Calibration Returns Apply gas and select the appropriate concentration and Click the ...
  • Page 11: Liability

    Oxygen Transmitter – Manual CO2Meter.com iSense Oxygen Transmitter – Manual CO2Meter.com Contact Us To obtain an RMA number, please call CO2Meter.com at (877) 678‐ 4259. When requesting an RMA number, please provide the reason for  We are here to help!  return and original order number.   If the troubleshooting guide above doesn’t help you solving your  If we determine that the product failed due to improper use (water  problem or for more information, please contact us using the  damage, dropping, tampering, electrical damage etc.) or abuse, or if it  information below.   is beyond the warranty period, we will inform you of the cost to fix or  replace your device.   support@co2meter.com  If you are returning your device due to a warranty claim (with an RMA   (386) 872‐7665 M‐F 9:00am–6:00pm EST  number) and you still have the unit original package, please use it to  ship your unit to us. Please make sure to include the provided RMA   (866) 422‐2356  number on the outside of the box, preferably on the shipping label.  Make sure you secure the unit inside the package properly to prevent   www.co2meter.com  any damage during transit that could void your device’s warranty.  Address:  Finally, please ship your device to the address shown under the  CO2Meter, Inc.  “Contact Us” section below. CO2Meter.com will not, under any  131 Business Center Drive ...

This manual is also suitable for:

Isense cm-0181

Table of Contents