Battery pack
Nominal voltage
Compatible charger
(not included)
Battery capacity
Charger input
Maximum charging
time
(BCL3617S)
Quick recharge
(BCL3617S)
FUEL GAUGE
See figure
To display the amount of charge left in the battery, press
the fuel gauge button.
If four LEDs glow green, the battery pack is fully
charged. The battery pack capacity is between 75%–
100%.
If three LEDs glow green and one is off, the battery
pack capacity is between 50%–75%.
If two LEDs glow green and other two are off, the
battery pack capacity is between 25%–50%.
If only one LED glows green and others are off, the
battery pack capacity is lower than 25%. In this case,
the battery pack can be used as usual until automatically
turned off by the control program.
If only one LED glows green but battery pack can not
release power, the battery pack needs to be charged.
2
1. LED
2. Fuel gauge button
2
BPL3620D
BPL3626D2
BCL3620, BCL3620S, BCL3650F, BCL3617S, BCL3617U
2.0 Ah
2.6 Ah
80 minutes
105 minutes
45 minutes
60 minutes
1
BPL3640D2
36 V
4.0 Ah
220–240 V, 50 Hz, AC only
160 minutes
60%
96 minutes
BATTERY PROTECTION FEATURES
RYOBI 36V Lithium-Ion batteries are designed with
features that protect the Lithium-Ion cells and maximise
battery life. If the tool stops during use, the following may
be the causes:
The maximum current draw of the battery has been
exceeded, causing it to automatically stop powering
the tool. Reset the tool: Release and pull the trigger or
remove and reinstall the battery pack.
Excessive temperatures can cause the battery to stop
powering the tool. Feel the battery pack; if it is too
warm, allow it to cool down.
If the tool still does not work, the battery may not be
sufficiently charged. Recharge the battery.
NOTE: The battery pack LED indicator will not work if the
battery protection feature has caused the battery pack
to stop powering the tool. Release and pull the trigger or
remove and reinstall the battery pack. Check the fuel gauge
if the battery pack LED indicator has resumed normal
function.
CHARGING THE BATTERY PACK
Battery packs are shipped in a low charge condition.
Charge them until the green LED on the front of the charger
stops flashing and stays solid green.
If the charger does not charge the battery pack under
normal circumstances, contact an Authorised Service
Centre for related advice.
TO CHARGE
Use a battery pack only with the recommended charger.
Connect the charger to the power supply. Make sure
the power supply is the normal household voltage,
220–240 volts, AC only, 50–60 Hz.
Make sure that the latch of the battery pack clicks into
place and the battery pack is secured in the charger
before beginning operation.
BPL3650D2
5.0 Ah
200 minutes
120 minutes