  • Page 3: Table Of Contents

    7.3.2. Transmitting Data to A Computer (CSV File) ......21 7.3.3. Transmitting Data to A Computer Real-TimeTransmission Mode) ..................22 7.3.3.1 Transmitting Only Environmental Data ........22 7.3.3.2. Transmitting Weighing Data and Environmental Data ..23 8. Replacement for Batteries and Sensor Unit ........ 24 9. Specifications ................26...
  • Page 4: Compliance

    1. C C ompliance Compliance with FCC Rules Please note that this device generates, uses and can radiate radio frequency energy. This device has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules.
  • Page 5: Introduction

    The AD-1687 is a data logger equipped with 4 sensors: temperature, humidity, barometric pressure and vibration. By connecting the output of the AD-1687 to the RS-232C of the insutrument, it is possible to record weighing data and environmental data sets.
  • Page 6: Caution During Use

    When operating this instrument, be sure to observe the following. Caution Do not open the case to repair the AD-1687. Only authorized personnel can perfrm repairs. Attempting repairs yourself may cause damage to the AD-1687 and will void the warranty.
  • Page 7: Unpacking And Names

    3. U U npacking and Names Main unit Battery box (back side) Temperature & humidity sensor unit Interval (Replaceable) indicator Low battery Optional connector for indicator a second temperature sensor Measurement Water resistant monitor connector cover Protector RS-232C connector for...
  • Page 8: Display And Key Operations

    4. Display and Key Operations The following five displays can be selected depending on the intended use. By pressing the SELECT key repeatedly, five different displays will appear. Environmental data display screen Setting screen Monitor display screen Trend graph to monitor two data...
  • Page 9 2. Monitor display screen This screen displays the two environmental data that were specified in the setting screen. (Refer to "6.2 Setting the Monitor Display") Temperature Humidity 3. Trend graph to display the environmental data (with example) Temperature chart Relative humidity chart Barometric pressure chart Optional second temperature chart...
  • Page 10 4. Trend graph to monitor two data (with example) This screen displays the two environmental data that were specified in the setting screen.(Refer to "6.2 Setting the Monitor Display") Temperature chart Humidity chart Note The battery level indicator is displayed when the battery is used.
  • Page 11 *2. The display will be turned off about one minute later when battery power is used except during the interval measurement. The AD-1687 is not turned off while the power is supplied by an external power, such as a weighing instrument, personal computer, AC adopter.
  • Page 12: How To Use

    The time to show or hide the display can be specified at the parameter "POWER SAVE" in the "6.4 Function Table". After being idle for one minute, the AD-1687 is turned off while using battery power (The factory setting). During the interval recording, should the recording data memory become full, the interval recording stops automatically, and the power is turned off.(The factory default recording system...
  • Page 13: Management Of Items

    UP, DOWN key: Selects a parameter. ENTER key: Stores new parameter and proceeds to next item. ON / OFF key: Cancels and proceeds to next item or menu. 4. Operations after finishing the management. SELECT key: Proceeds to the intended display...
  • Page 14: Interval Time

    This is the same as item "INTERVAL TIME" of the "6.4.Function". 6.2. Primary Data Specify two items to display from the temperature, relative humidity, barometric pressure, vibration and weighing data with "PRIMARY DATA" display or "Trend graph" display. Refer to item "PRIMARY DATA" of the "6.4.Function". 6.3. Clear Delete the stored data that is the last data or all.
  • Page 15: Function Table (Function)

    6 6 .4. Function Table (Function) The function table can specify each action of the function and the communication of the AD-1687. Items of each functions are stored as a parameter. These parameters are stored in the AD-1687 even without power.
  • Page 16 Record the Maximum ON ..Record the maximum value Value of the Vibration of the air flow and vibration in PEAK HOLD the interval time (Refer to "7.1. Record the Maximum Value of the Vibration") Every* ..
  • Page 17: About Csv File Name (Id Number)

    6.4.1. A A bout CSV File Name (ID Number) The CSV file name that is stored in the AD-1687 will be "AD-1687_ID number .CSV" You can create a new name which is easier to manage by changing the ID number.
  • Page 18: Applyed Funciton Setting

    The Vibration (Peak Hold) In the Factory setting "PeakHold OFF", the value of the vibration to be recorded in the AD-1687 is the value of the interval recording. If "PeakHold ON" mode is set, which records the maximum value of the vibration, the peak value during each interval time is held and recorded, the peak value during each interval time is held and recorded.
  • Page 19 (Example) To record at 1minute interval time Line Vibration values received by the AD-1687. The value of vibration to be recorded in the factory setting "PeakHold OFF" The value of vibration to be recorded in the peak-hold mode "PeakHold ON"...
  • Page 20: Connecting To The Weighing Instrument

    ON/OFF key after finishing the measurement. 7 7 .2. Connecting to the Weighing Instrument The AD-1687 saves the weighing data and environment data at the same time when receiving the weighing data. The Management of the Weighing Data 7.2.1.
  • Page 21: The Interval Measurement For The Weighing Instrument

    "Every") Step 2 Connect the Weighing instrument that has been set in the stream output. In the case that the AD-1687 has received the weighing data, is displayed at lower left corner of the screen of the AD-1687, and the weighing data is displayed In this case, the weighing data is not saved.
  • Page 22: Connecting To The Computer

    Supplying the Power From USB Port of 7.3.1. Computer Step 1 Connect the AD-1687 and a computer with a USB cable. Step 2 Select the item "EXT.POWER" and press the ENTER key so that the AD-1687 can use power from the USB port.
  • Page 23: Transmitting Data To A Computer (Csv File)

    Step 3 The AD-1687 is recognized as USB memory without special software. Step 4 The CSV file data can be read by the computer. Step 5 To delete the CSV file in the AD-1687, use normal computer file operations. Step 6 Follow the menu "Safely Remove Hardware" when removing the AD-1687 from the USB port of the computer.
  • Page 24: Real-Timetransmission

    Data is not stored in the AD-1687.(Special software is not necessary) Transmitting Only Environmental Data 7.3.3.1 Step 1 Connect the AD-1687 and a computer with a USB cable. The display will change to "7.3.1" Display after Connecting. Step 2 Select the item "REAL TIME" and press the ENTER key to use the real time transmission mode.
  • Page 25: Transmitting Weighing Data And Environmental Data

    Step 1 Connect the AD-1687 to the weighing instrument with the RS-232c cable while the AD-1687 is powered off. After that, connect the AD-1687 unit to the PC with the USB cable. After connecting, the display will change the "8.3.1" display.
  • Page 26: Replacement For Batteries And Sensor Unit

    (Low battery mark) is indicated. Do not mix an old battery with a new battery. Insert each battery with its positive (+) and negative (-) terminals properly aligned with the corresponding symbols in the battery compartment. When the batteries are drained completely, (Low battery mark) does not appear.
  • Page 27 When the sensor life has been exceeded or condensation is present on the sensor, an abnormal value may be displayed. Step 1 Turn of the AD-1687. Remove the protector. Step 2 Push the side of the battery cover to release hook and open it.
  • Page 28: Specifications

    Adaptable operating Windows 7, 8, 10 (32 bits, 64 bits) systems Operating to 60 , 85 RH or less environment (No condensation) 127(W) 90(H) 36(D) mm Dimensions (including the protector) AD-1687 body Approx. 280g mass (including batteries and the protector)
  • Page 29 MEMO...
  • Page 30 MEMO...
  • Page 32 3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013, JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-1566 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jose, California 95131, U.S.A. Telephone: [1] (408) 263-5333 Fax: [1] (408)263-0119 A&D INSTRUMENTS LIMITED Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 A&D AUSTRALASIA PTY LTD...